RCMB104 chipset D0569

The RCMB104 chipset D0569 for AC/DC sensitive residual current monitoring is used in combination with a measuring current transformer and a type A RCD provided in the installation for fault current monitoring of AC charging systems for electric vehicles in which AC or DC fault currents can occur. 

Depending on the variant, the chipset is suitable for integration into a charging unit (Mode 2, IC-CPD) in accordance with IEC 62752 or UL 2231-2 (CCID5 or CCID20). 

Our components for measuring fault currents provide you with a state-of-the-art solution for reliable measurement in various applications. The combination of the powerful CCE4400 sensor, the intelligent microcontroller and the flexible firmware makes this system an outstanding choice for your IC-CPD requirements. Rely on Bender for precision, conformity and safety in your electrical installation. 

The centrepieces of this advanced solution are the Bender ASIC CCE4400 and a powerful microcontroller with firmware D0569. 

Questions? Contact us!

Chipset D0569

The RCMB104 chipset D0569 for AC/DC sensitive residual current monitoring is used in combination with a measuring current transformer and a type A RCD provided in the installation for fault current monitoring of AC charging systems for electric vehicles in which AC or DC fault currents can occur. 

Depending on the variant, the chipset is suitable for integration into a charging unit (Mode 2, IC-CPD) in accordance with IEC 62752 or UL 2231-2 (CCID5 or CCID20). 

Our components for measuring fault currents provide you with a state-of-the-art solution for reliable measurement in various applications. The combination of the powerful CCE4400 sensor, the intelligent microcontroller and the flexible firmware makes this system an outstanding choice for your IC-CPD requirements. Rely on Bender for precision, conformity and safety in your electrical installation. 

The centrepieces of this advanced solution are the Bender ASIC CCE4400 and a powerful microcontroller with firmware D0569. 

Questions? Contact us!

Features

  • Four outputs (Switch1, Switch2, Error, PWM) 
  • Measuring range ±300 mA 
  • Residual current resolution 0.2 mA 
  • Patented measurement technology (patents: EP 2 571 128 / US 9,397,494 / ZL 201210157968.6 / CN 103001175, EP 2 813 856) 
  • Load current up to 32 A RMS (single-phase) or 3 x 32 A RMS (three-phase) (depending on device) 
  • Fault output (integrated self monitoring and test functions)
  • High insensitivity to external interferences 
  • Available variants for application in accordance with IEC 62752 and UL 2231-2 
  • Wide range of use even in severe environments (e.g. in the event of external interference fields) 
  • Can replace a type B RCD in applications in accordance with IEC 62752 when combined with a type A RCD and a suitable switching device (e.g. power relay). 
  • Chipset consisting of ASIC and microcontroller 
  • Compatible with various measuring current transformers (see table) 
  • Optimized for low cost designs

Applications

  • AC charging systems for electric vehicles in which AC or DC fault currents can occur 

RCMB104 chipset D0569 Variant(s)

TypeDescriptionArt. No.
CCE4400 Sensor circuitB980399
MicrocontrollerProgrammed with IC-CPD analysis software D0569B98039701

Compatible with various measuring current transformers 

TypeDescriptionArt. No.
WN12-01Current transformer ø12 mm, 1 N AC 16 AA166540
WN18-10Current transformer ø18 mm, 3 N AC 32 AB98080062
W15BS-02Current transformer with cable 18 cmB98080067
CTBC17P-03Current transformer ø 17 mm, PCB mountingB98080070
CTBC17P-03-K0325Current transformer ø 17 mm, cable variant (length 325 mm)B98080071
CTBC17 cable1470Cable incl. clip enclosure, Connector length 1470 mmB98080542
CTBC17 cable600Cable incl. clip enclosure, Connector length 600 mmB98080543
CTBC17 cable325Cable incl. clip enclosure, Connector length 325 mmB98080541
CTBC17 cable180Cable incl. clip enclosure, Connector length 180 mmB98080540

Downloads for RCMB104 chipset D0569

NameCategorySizeLanguageTimestampD-/B-Number
Chipset D0569 Manuals 2.4 MB EN2024/03/1515.03.2024D00508