Bender works in close cooperation with the manufacturers of gantry crane systems to optimise protection against electrical faults and guarantee the safety of the operating personnel. Insulation monitoring or residual current monitoring ensure high levels of safety and availability.
By means of insulation monitoring or residual current monitoring, Bender ensures the highest possible level of safety for people and systems and therefore guarantees a high level of system availability during embarking and disembarking or rather loading and unloading.
Moorings are often problematic in marinas. A central power supply feeds a large number of moorings, but there is no residual current monitoring for the individual moorings. This can lead to undetected fault currents being conducted from one boat through the water and damaging other boats in the process. Central shutdown via an RCD (fault current circuit breaker) means all moorings are de-energised, even if there is an electrical fault on one mooring only.
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
Product Overview ISOMETER®/ISOSCAN® | Product Overviews | 5.3 MB | EN | 2024/02/1616.02.2024 | |
Product Overview - Residual Current Monitoring | Product Overviews | 6.2 MB | EN | 2023/11/0909.11.2023 | |
Megayacht - Residual current monitoring in the luxury segment | Market Segment Brochures | 1.1 MB | EN | 2024/02/2222.02.2024 | |
Electrical Safety in Control and Auxiliary Circuits | Technical article | 632.6 KB | EN | 2019/05/1313.05.2019 |
Products
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Insulation monitoring device for inverter applications and large industrial plants
AC/DC sensitive measuring current transformer (Type B)
The advanced Neutral Grounding Resistor Monitor for sophisticated applications
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Insulation monitoring device for inverter applications and large industrial plants
AC/DC sensitive measuring current transformer (Type B)
The advanced Neutral Grounding Resistor Monitor for sophisticated applications
Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicles charging stations
Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems.
Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems
Electrical safety in low voltage distribution systems up to 1000 V ac and 1500 V dc - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems