The insulation fault locators ISOSCAN® EDS440 are used in connection with the ISOMETER® iso685-D-P or the locating current injector PGH to locate insulation faults in unearthed power supply systems (IT systems).
They detect locating current signals generated by the insulation monitoring device iso685-D-P or the locating current injector PGH and evaluate them correspondingly. Up to 12 measuring current transformers can be connected to an EDS440. In total, up to 50 insulation fault locators can be connected via an RS-485 interface (BS bus protocol) and thereby up to 600 outgoing circuits can be monitored.
The insulation fault locators ISOSCAN® EDS440 are used in connection with the ISOMETER® iso685-D-P or the locating current injector PGH to locate insulation faults in unearthed power supply systems (IT systems).
They detect locating current signals generated by the insulation monitoring device iso685-D-P or the locating current injector PGH and evaluate them correspondingly. Up to 12 measuring current transformers can be connected to an EDS440. In total, up to 50 insulation fault locators can be connected via an RS-485 interface (BS bus protocol) and thereby up to 600 outgoing circuits can be monitored.
Type | Supply voltage US* | Response value | LED display | Option "W" | Art. no. |
---|---|---|---|---|---|
EDS440-S-1 | DC 24 | 2…10 mA | -- | -- | B91080201 |
EDS440W-S-1 | DC 24 V | 2…10 mA | -- | ✓ | B91080201W |
EDS440-L-4 | AC/DC 24…240 V | 2…10 mA | ✓ | -- | B91080202 |
EDS440W-L-4 | AC/DC 24…240 V | 2…10 mA | ✓ | ✓ | B91080202W |
EDS440-LAF-4 | AC/DC 24…240 V | 10 mA | ✓ | -- | B91080209 |
*Absolute values
Accessories
Type | Supply voltage US | Art. no. |
---|---|---|
DI-1PSM (RS-485 repeater) | AC/DC 24 V ± 20 % | B95012044 |
DI-2USB (interface converter RS-485/USB) with USB cable | Supplied by USB interface | B95012045 |
IOM441-S (input/output module) | 12-fold relay module | B95012057 |
Measuring current transformer for EDS440
Type | Internal diameter/mm | Design type | Art. no. |
---|---|---|---|
CTAC20 | ø 20 | circular | B98110005 |
CTAC35 | ø 35 | circular | B98110007 |
CTAC60 | ø 60 | circular | B98110017 |
CTAC120 | ø 120 | circular | B98110019 |
CTAC210 | ø 210 | circular | B98110020 |
WS20x30 | 20 x 30 | split-core | B98080601 |
WS50x80 | 50 x 80 | split-core | B98080603 |
WS80x120 | 80 x 120 | split-core | B98080606 |
Alternative measuring current transformer from the Bender program
Type | Internal diameter/mm | Design type | Art. no. |
---|---|---|---|
W10/600 | 10 | circular | B911761 |
W0-S20 | 20 | circular | B911787 |
W1-S35 | 35 | circular | B911731 |
W2-S70 | 70 | circular | B911732 |
W3-S105 | 105 | circular | B911733 |
W4-S140 | 140 | circular | B911734 |
W5-S210 | 210 | circular | B911735 |
WR70x175S | 70x175 | rectangular | B911738 |
WR115x305S | 115x305 | rectangular | B911739 |
WR150x350S | 150x350 | rectangular | B911740 |
WR200x500S | 200x500 | rectangular | B911763 |
WS50x80S | 50x80 | split-core | B911741 |
WS80x80S | 80x80 | split-core | B911742 |
WS80x120S | 80x120 | split-core | B911743 |
WS80x160S | 80x160 | split-core | B911755 |
Measuring current transformer for EDS440-LAF
Type | mm | Design type | Art. no. |
---|---|---|---|
CTAF500SET | 500 | flexible | B98110022 |
CTAF1000SET | 1000 | flexible | B98110023 |
Category | Name | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
Certificates | TÜV NORD - AGH150x, CTACx, CTBCx, EDS44x, CTUB10x, MRCDB30x and RCMB30x | 417.2 KB | EN | 2023/01/12 14:43:5312.01.2023 14:43:53 | |
Certificates | TÜV NORD - AGH150x, CTACx, CTBCx, EDS44x, CTUB10x, MRCDB30x und RCMB30x | 437.3 KB | DE | 2023/01/12 14:43:4612.01.2023 14:43:46 | |
CE Declarations of conformity | EDS44x | 88.3 KB | 2022/08/12 06:17:2512.08.2022 06:17:25 | ||
Quickstarts | EDS440/EDS441 | 2.0 MB | DE | 2019/05/13 10:31:5613.05.2019 10:31:56 | D00201 |
Quickstarts | EDS440/EDS441 | 2.0 MB | EN | 2019/05/13 10:31:5613.05.2019 10:31:56 | D00201 |
Quickstarts | EDS440/EDS441 | 2.0 MB | FR | 2019/05/13 10:31:5613.05.2019 10:31:56 | D00201 |
Quickstarts | EDS440/EDS441 | 2.0 MB | ES | 2019/05/13 10:31:5613.05.2019 10:31:56 | D00201 |
Manuals | EDS440/EDS441 | 41.9 MB | ZH | 2019/05/13 10:31:4013.05.2019 10:31:40 | D00201 |
Datasheets | EDS440/EDS441 | 2.4 MB | ES | 2019/05/13 10:31:3713.05.2019 10:31:37 | D00201 |
Datasheets | EDS440/EDS441 | 15.2 MB | ZH | 2019/05/13 10:31:3313.05.2019 10:31:33 | D00201 |
Quickstarts | EDS440/EDS441 | 1.5 MB | ZH | 2022/09/27 08:28:4927.09.2022 08:28:49 | D00201 |
Manuals | EDS440/EDS441 | 8.7 MB | DE | 2022/06/09 10:46:2909.06.2022 10:46:29 | D00201 |
Manuals | EDS440/EDS441 | 8.7 MB | EN | 2022/06/09 10:48:2109.06.2022 10:48:21 | D00201 |
Datasheets | EDS440/EDS441 | 1,017.6 KB | DE | 2021/11/02 09:52:5302.11.2021 09:52:53 | D00201 |
Datasheets | EDS440/EDS441 | 1,012.3 KB | EN | 2021/11/02 09:53:1502.11.2021 09:53:15 | D00201 |
Manuals | EDS440/EDS441 - Modbus-Einstellungen | 186.8 KB | DE | 2020/01/14 07:38:5514.01.2020 07:38:55 | D00201 |
Manuals | EDS440/EDS441 - Modbus settings | 189.8 KB | EN | 2020/01/14 07:37:4814.01.2020 07:37:48 | D00201 |
Application brochures | Selectief aardfout zoeksysteem EDS | 933.7 KB | NL | 2019/05/13 10:31:2813.05.2019 10:31:28 | |
Product Change Notification | EDS44x change of frontplate for new addressing concept | 135.8 KB | EN | 2019/05/13 10:31:5513.05.2019 10:31:55 | D00201 |
Flyer | Industrial EDS | 1.1 MB | EN | 2021/04/28 13:38:1328.04.2021 13:38:13 | |
Flyer | Healthcare EDS | 1.7 MB | EN | 2021/04/29 15:23:1529.04.2021 15:23:15 | |
Product Brochures | Mining | 11.7 MB | ES | 2020/05/22 14:37:3122.05.2020 14:37:31 |