Detecting insulation faults in cable systems quickly

Troubleshooting in cable systems

Location without disconnecting

Troubleshooting in cable systems

Permanently installed and portable Bender EDS fault location systems help with the quick and accurate pinpointing of faults, thus saving time and money.

Product overview ISOMETER®
Technical paper Insulation fault location - Planning and set up in the solar charging station at the University of Applied Sciences Bingen
Brochure Railway technology
EN 61557-8
Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems 

EN 61557-9

Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems

Recurrent tests

Measuring instead of disconnecting - Compliant expert solutions

[] Retrofit

All electrical equipment must be tested on a regular basis. This is a requirement of DGUV Vorschrift 3 and also in the interests of the system operator. After all, tests prevent high repair costs and consequential damage as a result of poor maintenance. It is also the only way to guarantee optimum configuration of devices and systems. Bender offers solutions for measuring without disconnection.

Bender Service portal
Brochure Railway technology
IEC 60364-7-710
Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations

IEC 60947-6-1

Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment

Retrofitting

Does my system still meet the current requirements?

Retrofitting

Even with state-of-the-art electrical engineering equipment, time can take its toll. Whether it is a decline in operational reliability, changes in statutory regulations or increasing energy costs: adapting to the latest state of the art is crucial. Typically, products to monitor energy quality and for troubleshooting are retrofitted. Get us to test your electrical systems and we will give you suggestions as to how to proceed.

Brochure Railway technology
Product overview ISOMETER®
Brochure Bender Remote Assist
Application Note EDS309x
Technical paper Insulation fault location - Planning and set up in the solar charging station at the University of Applied Sciences Bingen

Recommended systems for insulation monitoring:

Recommended test systems:

Recommended systems for insulation fault location:

Empfehlenswerte Einrichtungen zur permanenten Überwachung:

IEC 60364-7-710
Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations

IEC 60947-6-1

Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment