The NGRM700 is an advanced device that allows continuous NGR monitoring to provide all necessary information of the system grounding.
The NGRM700 monitors the resistance value of the Neutral Grounding Resistor (NGR) and the fault current flowing through the NGR in High Resistance Grounded (HRG) systems. The ideal relay to protect HRG systems and to provide a comprehensive overview. The relay can be connected to the supervision system or directly to the communication network.
The NGRM700 allows the user to meet local requirements.
The NGRM700 is an advanced device that allows continuous NGR monitoring to provide all necessary information of the system grounding.
The NGRM700 monitors the resistance value of the Neutral Grounding Resistor (NGR) and the fault current flowing through the NGR in High Resistance Grounded (HRG) systems. The ideal relay to protect HRG systems and to provide a comprehensive overview. The relay can be connected to the supervision system or directly to the communication network.
The NGRM700 allows the user to meet local requirements.
Type | Supply voltage US / Frequency range Hz | Art. No. |
---|---|---|
NGRM700 | AC 24…240 V, 40…70 Hz DC 24…240 V | B94013700 |
Accessory for FP200-NGRM: Transparent front cover 144x72 (for IP65)* | B98060005 |
*When using the "transparent front cover 144x72 (IP 65)" the cutout in the switchboard cabinet must be extended in height from 66 mm to 68 mm (+0.7/-0 mm).
The degree of protection IP65 applies only to the user interface FP200-NGRM when using the front cover. The degree of protection for the complete device is still IP30.
CD-series coupling device
Type | Voltage Usys | Art. No. |
---|---|---|
CD1000 | 400…690 V | B98039010 |
CD1000-2 | 400…1000 V | B98039053 |
CD5000 | 1000…4200 V | B98039011 |
CD14400 | 4300…14550 V | B98039054 |
CD25000 | 14551…25000 V | B98039055 |
Measuring current transformer
Type | Voltage/Current | Art. No. |
---|---|---|
W20 | AC up to 10 A | B98080003 |
W35 W60 W0-S20 W1-S35 W2-S70 | AC up to 25 A | B98080010 B98080018 B911787 B911731 B911732 |
CTUB103-CTBC35 | AC/DC up to 10 A | B78120030 |
CTUB103-CTBC60 CTUB103-CTBC120 | AC/DC up to 25 A | B78120031 B78120032 |
Voltage supply for measuring current transformers CTUB103…
Type | max. connected measuring current transformers | Art. No. |
---|---|---|
STEP-PS/1 AC/24 DC/0.5 | 2 | B94053110 |
STEP-PS/1 AC/24 DC/1.75 | 7 | B94053111 |
STEP-PS/1 AC/24 DC/4.2 | 17 | B94053112 |
Category | Name | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
Flyer | NGR Product Comparison | 630.6 KB | EN | 2022/07/18 16:05:0218.07.2022 16:05:02 | |
CE Declarations of conformity | NGRM | 88.5 KB | 2023/05/03 09:41:4903.05.2023 09:41:49 | ||
Quickstarts | NGRM700/NGRM750 | 1.1 MB | DE | 2022/12/02 11:08:2902.12.2022 11:08:29 | D00292 |
Quickstarts | NGRM700/NGRM750 | 1.4 MB | EN | 2022/12/02 11:08:3102.12.2022 11:08:31 | D00292 |
Datasheets | NGRM700/NGRM750 | 1.0 MB | DE | 2023/03/16 11:55:3216.03.2023 11:55:32 | D00292 |
Datasheets | NGRM700/NGRM750 | 1.0 MB | FR | 2023/03/16 11:57:4116.03.2023 11:57:41 | D00292 |
Datasheets | NGRM700/NGRM750 | 1.1 MB | EN | 2023/03/16 11:56:2516.03.2023 11:56:25 | D00292 |
Datasheets | NGRM700/NGRM750 | 1.1 MB | ES | 2023/03/16 11:56:5216.03.2023 11:56:52 | D00292 |
Manuals | NGRM700/NGRM750 | 6.4 MB | DE | 2022/12/02 11:07:2902.12.2022 11:07:29 | D00292 |
Manuals | NGRM700/NGRM750 | 5.3 MB | EN | 2022/12/02 11:07:5502.12.2022 11:07:55 | D00292 |
Technical information | NGRM700 Guideform Specification (US) | 141.8 KB | EN | 2020/04/30 18:55:5630.04.2020 18:55:56 | |
Technical information | NGRM700 Guideform Specifications | 159.5 KB | ES | 2020/05/22 14:12:3022.05.2020 14:12:30 | |
Manuals | NGRM…-Modbus | 453.9 KB | DE | 2022/06/09 10:45:4109.06.2022 10:45:41 | D00292 |
Manuals | NGRM…-Modbus | 443.2 KB | EN | 2022/06/09 10:47:4409.06.2022 10:47:44 | D00292 |
Manuals | NGRM…-Modbus | 463.4 KB | ES | 2022/06/09 10:49:2509.06.2022 10:49:25 | D00292 |
Technical information | How to Size an NGR (US) | 424.0 KB | EN | 2019/05/13 10:31:3513.05.2019 10:31:35 | |
Technical information | How to size an NGR (ES) | 426.7 KB | ES | 2021/05/26 11:31:0926.05.2021 11:31:09 | |
Technical information | NGR Checklist (US) | 245.3 KB | EN | 2022/11/07 16:39:0207.11.2022 16:39:02 | |
Technical information | Guideline on NGR/Safety Ground Monitoring | 234.7 KB | EN | 2019/09/20 13:52:3320.09.2019 13:52:33 | |
Technical information | Guideline on NGRM Relay Testing | 522.3 KB | EN | 2021/10/26 18:41:5226.10.2021 18:41:52 | |
Application brochures | System Grounding in the Americas, Australia, South Africa and Other Regions | 576.7 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | |
Product Brochures | HRG & LRG Systems (US) | 5.2 MB | EN | 2020/03/05 21:02:3305.03.2020 21:02:33 | |
Flyer | Neutral Grounding Resistor Monitors (US) | 343.7 KB | EN | 2020/03/23 17:32:0023.03.2020 17:32:00 | |
Product Brochures | Mining | 11.7 MB | ES | 2020/05/22 14:37:3122.05.2020 14:37:31 |