ISOMETER® isoCHA425HV with AGH420-1

  • Switchable between CCS (Combined Charging System) and CHAdeMO
  • Nominal voltages up to DC 1000 V
  • Detection of symmetrical and asymmetrical insulation faults
  • Electrically isolated Modbus RTU interface
  • Display of the fault location (DC+/DC/balanced)

The ISOMETER® isoCHA425HV in combination with the coupling device AGH420-1 monitors the insulation resistance RF for DC fast charging stations according to CHAdeMO standard or according to Combined Charging System (CCS) for nominal system voltage ranges between DC 0 V and 1000 V.

In order to meet the requirements of applicable standards, customised parameter settings must be made on the equipment in order to adapt it to local equipment and operating conditions.

Please heed the limits of the area of application indicated in the technical data. Any use other than that described in this manual is regarded as improper.

Questions? Contactez-nous!

ISOMETER® isoCHA425HV mit AGH420-1
ISOMETER® isoCHA425HV mit AGH420-1
  • Switchable between CCS (Combined Charging System) and CHAdeMO
  • Nominal voltages up to DC 1000 V
  • Detection of symmetrical and asymmetrical insulation faults
  • Electrically isolated Modbus RTU interface
  • Display of the fault location (DC+/DC/balanced)

The ISOMETER® isoCHA425HV in combination with the coupling device AGH420-1 monitors the insulation resistance RF for DC fast charging stations according to CHAdeMO standard or according to Combined Charging System (CCS) for nominal system voltage ranges between DC 0 V and 1000 V.

In order to meet the requirements of applicable standards, customised parameter settings must be made on the equipment in order to adapt it to local equipment and operating conditions.

Please heed the limits of the area of application indicated in the technical data. Any use other than that described in this manual is regarded as improper.

Questions? Contactez-nous!

Caractéristiques

  • Monitoring of the insulation resistance RF of DC charging stations according to CHAdeMO standard or Combined Charging System (CCS)
  • CHAdeMO (Mode CHd and CHA):
    – Maximum system leakage capacitance 1.6 μF per conductor
    – Detection of insulation faults in the system voltage range 50 V to 1000 V
    – One-pole insulation faults RFU: RFU≤ 100 kΩ: Response time ≤ 1 s, 100 kΩ < RFU≤ 2 MΩ: Response time ≤ 10 s – Two-pole insulation faults RFS: RFS ≤ 160 kΩ: Response time ≤ 10 s, RFS > 160 kΩ (200 kΩ): no detection (Deactivation) (only CHd)
  • CCS (Mode dc):
    – Detection of insulation faults up to 2 MΩ
    – Maximum system leakage capacitance Ce: 20 μF
    – Response time tan at Ce ≤ 5 μF or RF ≤ 100 kΩ: ≤ 10 s
  • Measurement of the system leakage capacitance Ce
  • Measurement of the nominal system voltage Un (True RMS) with undervoltage/overvoltage detection
  • Measurement of the DC residual voltages UL1e (between L1/+ and earth) as well as UL2e (between L2/- and earth)
  • Selectable start-up delay, response delay and delay on release
  • Two separately adjustable response value ranges of 5...600 kΩ (Alarm 1, Alarm 2)
  • Alarm signalling via LEDs (“AL1”, “AL2”), a display and alarm relays (“K1”, “K2”)
  • Automatic device self test with connection monitoring
  • Selectable N/C or N/O relay operation
  • Measured value indication via a multifunctional LC display
  • Fault memory can be activated
  • RS-485 (galvanically isolated) including the following protocols:
    – BMS interface (Bender measuring device interface) for data exchange with other
  • Bender components
    – Modbus RTU
    – IsoData (for continuous data output)
  • Password protection to prevent unauthorised parameter changes
  • Stop mode to deactivate the measuring pulse generator

Applications

  • DC charging stations for electric vehicles in accordance with the Japanese charging standard CHAdeMO
  • DC charging stations for electric vehicles according to CCS (Combined Charging System) in compliance with IEC 61851-23

ISOMETER® isoCHA425HV with AGH420-1 Variante(s)

TypeNominal system voltage UnArt. No.**
isoCHA425HV-D4-4 + AGH420-1DC 0 (50*)…1 000 VB71036396
B91036396

* Value for CHAdeMo
** (B7… = push-wire terminal / B9… = screw-type terminal)

Accessoires en option pour ISOMETER® isoCHA425HV with AGH420-1

TypeRéf.
Clip de montage pour fixation par vis (1 pièce est nécessaire par appareil)B98060008
Cadre de montage XM420B990994 

Téléchargements pour ISOMETER® isoCHA425HV with AGH420-1

TypeNomTailleLangueHorodatageD-/B-Numéro
Note d'application isoCHA425HV 276.7 Ko 2023/06/29 13:08:1929.06.2023 13:08:19D00404
Déclarations de conformité UKCA - isoxx425 142.1 Ko 2023/06/12 05:32:0112.06.2023 05:32:01
Déclarations de conformité CE isoXX425 146.2 Ko 2023/07/14 05:24:4714.07.2023 05:24:47
Notices isoCHA425HV 613.4 Ko DE2023/03/06 09:44:1006.03.2023 09:44:10D00404
Notices isoCHA425HV 607.3 Ko EN2023/03/06 09:44:1606.03.2023 09:44:16D00404
Dépliants isoCHA425HV 296.5 Ko DE2021/09/07 09:04:4307.09.2021 09:04:43D00404
Dépliants isoCHA425HV 295.9 Ko EN2021/09/07 09:04:5807.09.2021 09:04:58D00404
Manuels isoCHA425HV 2.1 Mo EN2023/02/20 10:51:2020.02.2023 10:51:20D00404
Manuels isoCHA425HV 2.1 Mo DE2023/02/20 10:51:1120.02.2023 10:51:11D00404
Dépliants isoCHA425HV (US) 794.2 Ko EN2021/03/11 18:16:0611.03.2021 18:16:06
Quickstarts isoCHA425HV 1,021.7 Ko DE2023/02/20 10:51:4520.02.2023 10:51:45D00404
Quickstarts isoCHA425HV 1,021.7 Ko EN2023/02/20 10:51:4520.02.2023 10:51:45D00404