1. OCPPMeterType
ID | Meter |
---|---|
73 | eHZ Meter via USB |
75 | eHZ-B Meter via USB |
6 | Modbus Meter ABB |
47 | Modbus ABB EV3 |
44 | Modbus Berg B23 |
43 | Modbus Berg BME 461 |
19 | Modbus TQ EM300-LR |
41 | Modbus TQ EM410/EM420 |
25 | Modbus TQ EM300-LR (TCP) |
42 | Modbus TQ EM410/EM420 (TCP) |
81 | Modbus IPD Control (TCP) |
86 | Modbus Meter Carlo Gavazzi EM111/112 |
20 | Modbus Meter Carlo Gavazzi EM200 |
29 | Modbus Meter Carlo Gavazzi EM210 |
21 | Modbus Meter Carlo Gavazzi EM340 |
37 | Modbus DZG DVH4013 |
7 | Modbus Meter Eastron SDM630 |
58 | Modbus Eastron SDM230 |
8 | Modbus Eastron SDM120_220 |
39 | Modbus Eastron SDM72D |
68 | Modbus Eastron SDM72D-M-V2 |
32 | Modbus ECS M3PRO |
54 | Modbus ECS M3PRO (TCP) |
13 | Modbus Meter Finder |
12 | Modbus Meter Garo EM270 |
10 | Modbus Meter Garo GNM1D |
9 | Modbus Meter Garo GNM3D |
22 | Modbus Meter Garo GNM3T |
28 | Modbus Meter Garo GNM3TD |
11 | Modbus Meter Garo GM3T |
80 | Modbus Meter Garo GMI3D-LP |
38 | Modbus Gossen Metrawatt EM2289 |
27 | Modbus Hager ECR380D |
23 | Modbus IME CE4DMID31 |
87 | Modbus IME CE4DF3DTMID |
15 | Modbus Inepro PRO1_2 |
16 | Modbus Inepro PRO380 |
84 | Modbus Wago 879-3000 |
40 | Modbus Iskra WM3M6 |
78 | Modbus Iskra IE38M |
79 | Modbus Meter Finder 7M38 |
33 | Modbus Janitza UMG 512/96 PRO |
34 | Modbus Janitza UMG 512/96 PRO (TCP) |
85 | Modbus Janitza UMG 604 PRO (TCP) |
35 | Modbus Janitza UMG 605 PRO |
36 | Modbus Janitza UMG 605 PRO (TCP) |
64 | Modbus NZR EcoCount S85/SL85 |
17 | Modbus Optec |
45 | Modbus Phoenix Contact EEM-EM357 |
30 | Modbus Phoenix Contact EEM-MB371 (TCP) |
14 | Modbus Saia ALE3 |
83 | Modbus Schneider Generic (TCP) |
82 | Modbus Schneider Generic |
31 | Modbus Schneider iEM3555 |
26 | Modbus Siemens 7KM2200 (TCP) |
24 | Modbus Siemens 7KT1666 |
49 | Modbus YTL DTS353F |
50 | EV Optimizer |
53 | Modbus SELEC EM2M-1P-C-100A |
55 | Modbus Lovato DMED 301 |
56 | Modbus Eetarp GEM630 |
57 | Modbus Eetarp GEM230 |
65 | Modbus DZG DWH4113 |
66 | Modbus ABB D1M |
67 | Modbus ABB D1M (TCP) |
60 | ER Eastron SDM630-EV |
61 | ER NZR EcoCount SL+SC 85 |
63 | ER NZR EcoCount SL+S 85 |
62 | ER Iskra WM3M4C |
69 | ER EMH iML |
1 | S0 Meter 'Opto 1 In' |
72 | Modbus Eichrecht |
3 | No Meter |
2. SecondMeterType
ID | Meter |
---|---|
77 | WiMOD IR Reader USB stick |
6 | Modbus Meter ABB |
47 | Modbus ABB EV3 |
44 | Modbus Berg B23 |
43 | Modbus Berg BME 461 |
19 | Modbus TQ EM300-LR |
25 | Modbus TQ EM300-LR (TCP) |
41 | Modbus TQ EM410/EM420 |
42 | Modbus TQ EM410/EM420 (TCP) |
81 | Modbus IPD Control (TCP) |
86 | Modbus Meter Carlo Gavazzi EM111/112 |
20 | Modbus Meter Carlo Gavazzi EM200 |
29 | Modbus Meter Carlo Gavazzi EM210 |
21 | Modbus Meter Carlo Gavazzi EM340 |
7 | Modbus Meter Eastron SDM630 |
58 | Modbus Eastron SDM230 |
8 | Modbus Eastron SDM120_220 |
39 | Modbus Eastron SDM72D |
68 | Modbus Eastron SDM72D-M-V2 |
32 | Modbus ECS M3PRO |
54 | Modbus ECS M3PRO (TCP) |
13 | Modbus Meter Finder |
12 | Modbus Meter Garo EM270 |
10 | Modbus Meter Garo GNM1D |
9 | Modbus Meter Garo GNM3D |
22 | Modbus Meter Garo GNM3T |
28 | Modbus Meter Garo GNM3TD |
11 | Modbus Meter Garo GM3T |
80 | Modbus Meter Garo GMI3D-LP |
27 | Modbus Hager ECR380D |
23 | Modbus IME CE4DMID31 |
87 | Modbus IME CE4DF3DTMID |
15 | Modbus Inepro PRO1_2 |
16 | Modbus Inepro PRO380 |
84 | Modbus Wago 879-3000 |
40 | Modbus Iskra WM3M6 |
78 | Modbus Iskra IE38M |
79 | Modbus Meter Finder 7M38 |
33 | Modbus Janitza UMG 512/96 PRO |
34 | Modbus Janitza UMG 512/96 PRO (TCP) |
85 | Modbus Janitza UMG 604 PRO (TCP) |
35 | Modbus Janitza UMG 605 PRO |
36 | Modbus Janitza UMG 605 PRO (TCP) |
64 | Modbus NZR EcoCount S85/SL85 |
17 | Modbus Optec |
45 | Modbus Phoenix Contact EEM-EM357 |
30 | Modbus Phoenix Contact EEM-MB371 (TCP) |
14 | Modbus Saia ALE3 |
83 | Modbus Schneider Generic (TCP) |
82 | Modbus Schneider Generic |
31 | Modbus Schneider iEM3555 |
26 | Modbus Siemens 7KM2200 (TCP) |
24 | Modbus Siemens 7KT1666 |
49 | Modbus YTL DTS353F |
51 | Modbus Sunspec Meter |
52 | Modbus Sunspec Meter (TCP) |
50 | EV Optimizer |
53 | Modbus SELEC EM2M-1P-C-100A |
55 | Modbus Lovato DMED 301 |
56 | Modbus Eetarp GEM630 |
57 | Modbus Eetarp GEM230 |
59 | Modbus Temco Controls SPM1-XX0-AC |
88 | SMA Commercial Energy Meter (TCP) |
66 | Modbus ABB D1M |
67 | Modbus ABB D1M (TCP) |
1 | S0 Meter 'Opto 1 In' |
3 | No Meter |
3. Errors
Description: This section provides details for the Errors tab extracted from the documentation HTML.
OCPP Error code | Error activation message | Error resolution message | Transaction and charging is stopped | Notes | Corrective actions |
---|---|---|---|---|---|
groundFailure | Residual current detected via sensor | Residual current situation resolved | Yes | Internal RCMB device (yellow coil). This detects also DC residual current. | The safety mechanism is reset to its original state every time the cable is unplugged from the chargepoint. Otherwise the error is automatically reset after a delay of 10 seconds if the EV was unplugged. In case the RCMB version is older than or equal to D0469, the delay is 15 minutes. If the problem persists, please check the yellow current transformer (coil) and its connection. |
mode3Error | Vehicle signals error | Vehicle error resolved | No | Mode3 errors. | Disconnect EV and try again. If that doesn’t help, follow EV’s instructions. |
mode3Error | Vehicle diode check failed - tamper detection | Vehicle with diode problem disconnected | Yes | Mode3 errors. | Disconnect EV and try again. If that doesn’t help, follow EV’s instructions. |
overCurrentFailure | MCB of type 2 socket triggered | MCB type 2 reconnected | Yes | MCB needs to be re-armed, requires a maintenance visit. | |
overCurrentFailure | MCB of domestic socket triggered | MCB domestic socket reconnected | Yes | MCB needs to be re-armed, requires a maintenance visit. | |
groundFailure | RCD triggered | RCD reconnected | Yes | External RCD Device. | Up to a certain point this will be corrected automatically. |
groundFailure | RCD may be triggered (OCPP meter power loss) | RCD may be reconnected (OCPP meter recovered) | Yes | External RCD Device. | Up to a certain point this will be corrected automatically. |
otherError | Surge Protection Device (SPD) tripped. Replace. | Surge Protection Device (SPD) issue solved | No | External SPD Device. | Surge Protection Devices (SPD) needs to be replaced. |
powerSwitchFailure | Contactor welded | Contactor weld resolved | Yes | Very likely requires a maintenance visit with high priority as it is an indication there might now be a not properly disconnected socket while no plug is inserted. | |
connectorLockFailure | Plug locking failed | No | Typically caused by not fully inserted plugs, unplugging and attempting to plug again in most cases resolves the problem. | ||
connectorLockFailure | Type 2 actuator stuck, cannot unlock | Type 2 locking actuator recovered | Yes | A mechanical problem may require a maintenance visit. An Unlock Connector or Hard Reset triggers another attempt to unlock. | |
connectorLockFailure | Could not detect type 2 locking actuator | Type 2 locking actuator detected | Yes | A mechanical problem may require a maintenance visit. A Hard Reset triggers another attempt to redetect the actuator type. | |
powerMeterFailure | OCPP meter not communicating | OCPP meter communication recovered | Yes | ||
powerMeterFailure | External meter not communicating | External meter communication recovered | No | ||
noError | Meter eichrecht not supported | Meter eichrecht supported | No | Meter eichrecht not supported, connecting the Eichrecht meter is necessary for OCMF generation. | Check if meter supports eichrecht (public key should be displayed in state page). |
readerFailure | RFID reader not communicating | RFID reader recovered | No | ||
highTemperature | Cannot read temperature sensor | Temp sensor recovered | No | ||
highTemperature | Cannot read critical temperature sensor | Critical temp sensor recovered | Yes | ||
otherError | Voltage drop on HMICP detected | Voltage drop on HMICP recovered | No | ||
otherError | Light sensor on HMICP failure | Light sensor on HMICP failure solved | No | ||
otherError | Temperature sensor on HMICP failure | Temperature sensor on HMICP failure solved | No | ||
otherError | Humidity sensor on HMICP failure | Humidity sensor on HMICP failure solved | No | ||
otherError | Gyroscope sensor on HMICP failure | Gyroscope sensor on HMICP failure solved | No | ||
otherError | Shock sensor on HMICP failure | Shock sensor on HMICP failure solved | No | ||
otherError | Communication with HMICP failed | Communication with HMICP failure solved | No | ||
otherError | HMICP controller failed | HMICP controller failure solved | No | ||
highTemperature | Housing temperature too high - charging paused | Housing temp. below critical - charging resumed | No | ||
noError | Housing temp. approaching limit - current reduced | Housing temp. back to normal - current restored | No | ||
highTemperature | DC wallbox temperature too high - charging paused | DC wallbox temperature below critical | No | ||
highTemperature | Relay temperature too high - charging paused | Relay temp. below critical - charging resumed | No | ||
noError | Relay temp. approaching limit - current reduced | Relay temp. back to normal - current restored | No | ||
otherError | Temperature reaches safety limit - emergency stop | Temperature below safety limit - resume | Yes | ||
weakSignal | SignalWeak:0///0 | SignalGood:0///0 | No | Low RSSI limit is 12 and high limit is 14. | |
otherError | GSM SIM card is missing | GSM SIM card inserted | No | GSM SIM card is missing. | Insert a SIM card in the dedicated slot. |
otherError | FW Update in progress | FW Update finished | Yes | FW update command issued while update is already in progress. | Try again after first command was processed. Otherwise carry out a hard reset. |
otherError | FW/USB Update failure deleted | No | Firmware update failed. | Try again. | |
noError | USB communication errors. | USB communication working properly. | No | USB communication errors. | Wait until application recovers from this error. |
otherError | The ChargePoint is tilted. | The ChargePoint no longer is tilted. | Yes | The ChargePoint has been tilted. | A physical inspection and maintenance is required at the ChargePoint location. |
otherError | Possible CP and PR wiring issue. | Possible CP and PR wiring issue is solved. | Yes | A car is detected but no cable is detected. | Check the wiring of CP and PR cables, they may be swapped or the plug may be broken. |
otherError | PR disconnected while car is connected. | PR disconnection issue is solved. | No | The proximity cable is disconnected while the car is plugged | Check the plug and socket PR contact, it may be defect. Check the internal PR wiring of the charging station and the charging cable. |
otherError | OCPP Master and Slave have different SW version. | OCPP Master and Slave have same SW version. | No | The master and slave have different SW versions. | Maybe the firmware update has failed or a manual update was performed incorrectly.Check what is the expected FW version and update firmware. |
otherError | RCMB measurement out of range. | Yes | The current transformer on the Chargepoint has a defect if this condition persists. | Replace the current transformer on the ChargePoint. | |
otherError | Car current is higher than expected. | Car is charging at nominal current. | No | The car is charging with SOCKET_TYPE2_CURR_OVERLOAD_THRESHOLD_1% more than expected according to the signaled current. The charge point will try to solve it by decreasing the signaled current | Check the car. |
otherError | Car current overload, charging stopped. | Car is charging at nominal current again. | Yes | The car is charging with a too high current. Charging will be stopped | Check the car. |
connectorLockFailure | Actuator unlocked while charging | Yes | For some reason the actuator was unplugged during charging. | Verify the actuator and actuator wiring | |
otherError | The chargepoint was previously tilted | Chargepoint tilted issue deleted | Yes | The chargepoint was previously tilted. | It is not allowed to charge until the charge point is rebooted. |
otherError | Not all DLM Slaves connected | All DLM Slaves are connected again | No | Some DLM slaves are disconnected from DLM master. | Reconnect the DLM slaves to the DLM master again. |
otherError | DLM Slave disconnected and not charging | DLM Slave is connected again | No | The DLM slave is disconnected from DLM master and its DisconnectedLimit is set to zero. | Reconnect the DLM slave to the DLM master again or increase its DisconnectedLimit. |
otherError | USB stick handling finished | Yes | USB stick is inserted and is being handled. | Wait until all operations have finished. | |
otherError | Phase rotation failure. | Phase rotation direction normal. | Yes | A different phase rotation dir. has been detected from the option selected in the configuration. Phases have either been incorrectly installed, or misconfigured. | Configuration has to be changed consistently according to detected phase rotation dir., or the phases have to be correctly installed. A physical inspection and maintenance may be required at the chargepoint location. |
underVoltage | There is no power on mains. | Grid power restored. | Yes | No power on mains has been detected. | A physical inspection and maintenance is required at the chargepoint location. |
otherError | Failed init: | No | A component or set of components failed to initialize correctly. | An inspection and maintenance is required for the chargepoint, issue probably has to be escalated to be handled by a support engineer. | |
otherError | State D detected, charging is paused | Car no longer in state D, charging is resumed | No | Charging is paused because state D is detected. | Check the reason why car goes to state D. |
underVoltage | Low voltage detected, charging is paused | Normal voltage detected, charging is resumed | No | Charging is paused because low voltage is detected. Charging will resume one minute after the electric grid stabilizes | Wait until the electric grid stabilizes. |
overVoltage | High voltage detected, charging is paused | Normal voltage detected, charging is resumed | No | Charging is paused because high voltage is detected. Charging will resume one minute after the electric grid stabilizes | Wait until the electric grid stabilizes. |
otherError | Low frequency detected, charging is paused | Normal frequency detected, charging is resumed | No | Charging is paused because low frequency is detected. Charging will resume one minute after the electric grid stabilizes | Wait until the electric grid stabilizes. |
overCurrentFailure | RCD-MCB triggered from unique input | RCD-MCB from unique input reconnected | Yes | RCD-MCB needs to be re-armed. | |
noError | USB stick handling: Finalized - Remove USB stick | USB stick removed | No | USB stick is still inserted while all previous operations completed successfully. | Remove the USB stick. |
noError | USB stick handling failed - Remove USB stick | USB stick removed | No | USB stick is still inserted while there were errors with previous operations. | Remove the USB stick and retry. |
noError | Socket type 2 plug lifetime exceeded | No | Socket type 2 plug should be replaced. | ||
connectorLockFailure | Actuator emergency opener faulted | Actuator emergency opener failure solved | Yes | A mechanical problem may require a maintenance visit. | |
groundFailure | Ground check (PE) failed | Ground check (PE) failure solved | No | A wiring problem may require a maintenance visit. | |
underVoltage | L1 voltage is missing | L1 voltage is not missing (contactor opened) | No | L1 line is not energized when it should since the contactor is closed | Verify that the charger wiring is correctand that no RCD or MCB protection is active. |
underVoltage | No | Error occurs if issued power line is either not connected or the varistor at this line is defective. | Check varistor fault or mains outage. | ||
otherError | Message queue is full | Message queue works again | Yes | Error occurs when the parameter "OcppQueueFullAsErrorState" was set by the operator and the OCPP message queue is full and cannot store further items. | Check the connection to the OCPP backend. |
otherError | Internal communication error | Internal communication error resolved | Yes | Unexpected internal SW communication error. | A system reboot is required. |
otherError | OCPP meter failure | OCPP meter failure resolved | Yes | OCPP meter reported a failure in the power line supply. | Check the power lines voltage, frequency and current. |
internalError | 15118 module failure | 15118 module failure resolved | No | 15118 module failed to initialize. | Reboot the chargepoint or check for hardware issues. |
internalError | QCA7000 initialization failure | QCA7000 initialization failure resolved | No | QCA7000 initialization failure. | Reboot the chargepoint or check for hardware issues. |
weakSignal | eth interface had 0 link up-down sequences. | Too many eth link up-down sequences resolved | No | Ethernet interface is having frequent disconnection and connections. | Verify the LAN network settings and state. |
noError | Socket type 2 contactor lifetime exceeded | No | Socket type 2 contactor should be replaced. | ||
underVoltage | Contactor not closed | Contactor error solved | No | Contactor or main relay has failed to close or it opened during charging | Verify that the charger wiring is correctand that the relay is in good condition. |
otherError | CP ADC calibration aborted. (Value out of range) | CP ADC calibration failure solved | No | CP ADC calibration was aborted due to an out of range ADC value. | The board might need an inspection by a technician. |
otherError | WLAN SSID or PSK is incorrectly configured | WLAN SSID and PSK are now correctly configured | No | WLAN was enabled but the SSID or the PSK was wrong. | Verify that WLAN SSID and the PSK was set correctly. |
otherError | Fan defect, ventilation could not be started | Fan ventilation functionality recovered | Yes | ||
otherError | Shock detected | Shock is not longer detected | Yes | ||
otherError | Tilt detected | Tilt is not longer detected | Yes | ||
otherError | Humidity is too high | Humidity is back to normal | No | ||
otherError | HMI180 temperature too low | HMI180 temperature back to normal | No | ||
otherError | HMI180 USB error | HMI180 USB error solved | No | ||
otherError | HMI180 USB communication error | HMI180 USB communication error solved | Yes | ||
otherError | Phytec temperature too high | Phytec temperature back to normal | Yes | ||
otherError | Phytec LCD temperature too high | Phytec LCD temperature back to normal | Yes | ||
otherError | Phytec LCD temperature too low | Phytec LCD temperature back to normal | No | ||
otherError | HMI180 Phytec communication error | HMI180 Phytec communication error solved | No | ||
otherError | LED ring temperature too high | LED ring temperature back to normal | No | ||
otherError | LED ring temperature too low | LED ring temperature back to normal | No | ||
otherError | LED group failure | LED group failure solved | No | ||
otherError | Payter temperature too high | Payter temperature back to normal | No | ||
otherError | Payter temperature too low | Payter temperature back to normal | No | ||
otherError | Payter communication error | Payter communication error solved | No | ||
otherError | WIFI module communication error | WIFI module communication error solved | No | ||
otherError | WIFI temperature too high | WIFI temperature back to normal | No | ||
noError | Threshold contactor cycles under load exceeded | Threshold contactor cycles exceeded solved | No | Socket type 2 contactor should be replaced. | |
otherError | Meter is 1-phase, but system setting is 3-phase. | Meter is 1-ph, but sys setting is 3-ph resolved. | No | Meter is 1-phase, but system is 3-phase. | Change the installation setting to 1-phase. |
noError | Authorization failed. | No | |||
otherError | Firmware update failed. | No | Firmware update failed (internet connection?). | Retry or perform a manual update. | |
resetFailure | Unintended Reset - Power Outage? | No | |||
resetFailure | Terminated transaction after reset! Power Outage? | No | ChargePoint rebooted while a transaction (charging) was active. Transaction was implicitely terminated. | Restart the transaction. | |
otherError | Slave is unavailable (disconnected from Master). | No | A Slave disconnected from the master. | Replace cable, repair connection, and wait until slave reconnects to master. | |
otherError | Diagnostics failed. | No | Diagnostics failed (internet connection?). | Retry. | |
groundFailure | RCMB error. | No | |||
evCommunicationError | 15118 communication error (exi decoder) | No | 15118 communication failed | ||
evCommunicationError | 15118 communication error (exi encoder) | No | 15118 communication failed | ||
evCommunicationError | 15118 communication error (TLS cert) | No | 15118 communication failed | ||
evCommunicationError | 15118 communication error (V2G session id) | No | 15118 communication failed | ||
evCommunicationError | 15118 communication error (TCP) | No | 15118 communication failed | ||
otherError | 15118 authorization failed | No | 15118 authorization for PnC failed. The signature validation failed | Install a valid certificate in the car and the correct root CA in the chargepoint | |
otherError | 15118 authentication failed | No | 15118 authentication for PnC failed | Install a valid certificate in the car and the correct root CA in the chargepoint | |
otherError | 15118 certificate installation failed | No | 15118 Certificate Installation failed | Verify that car and backend are handling the certificates properly | |
noError | System not yet ready. | No |
4. OCPP Keys
Description: This section provides details for the OCPP Keys tab extracted from the documentation HTML.
Key Name | Master/Slave Scope | OCPP standard | Description | Reboot Required | Accessibility | Type | Range, Default or example |
---|---|---|---|---|---|---|---|
RCMBDelta | Both | No | Minimum residual current change (in tenth of a milliamp) for which an OCPP status notification is sent to the backend. A value of 0 disables notifications. | No | R/W | uint | [0..999] Def: 0 |
RCMBIEC62955Mode | Individual | No | Configures the RCMB to comply with IEC62955 or IEC62752. Important note: If set to 'IEC62955 (locked)', the option 'IEC62752' will be permanently disabled and cannot be selected anymore from then on! | Yes | R | Enum | (0) IEC 62752 (1) IEC 62955 (2) IEC 62955 (locked) Def: IEC 62955 |
RCMB_STATE | Individual | No | RDC-M (RCMB) protection state Maximum values of last transaction Current values | No | R | String | Def: "DC: OK, RDC-M (RCMB) Device Status (IEC 62955): OK Last transactio..." |
RCMBTransactionMaxRMS | Individual | No | Largest RMS value measured while a transaction was in progress | No | R | String | Def: " 0.0" |
RCMBTransactionMaxDC | Individual | No | Largest DC value measured while a transaction was in progress | No | R | String | Def: " 0.0" |
WeldCheck | Individual | No | Welded contactor detection. For the '230V input' with and without PE check options (if available) L1 must be connected before the contactor. In these two cases weld check is only done when the car is disconnected and not immediately on opening the contactor. | Yes | R | Enum | (0) Disable (1) Enabled 'Opto 1 In' (3) Enable via weld check input 230V WITHOUT PE check (4) Enable via weld check input 230V WITH PE check Def: Disable |
WeldCheckInType | Individual | No | Whether the welding detection input circuit is normally closed or normally open. | Yes | R | Enum | (0) Normally open (1) Normally closed Def: Normally open |
ChargePointVendor | Both | No | Mandatory, identifies the vendor of the ChargePoint. | Yes | R | String | Def: "Bender GmbH Co. KG" |
ChargePointModel | Not relevant | No | Mandatory, identifies the model of the ChargePoint. Please note that this must not match a different model of the generation of charge controllers. | Yes | R | String | Def: "CC613_ELM4PR_M" |
SSHAccessUsb | Individual | No | Disables SSH access to the controller via USB. | Yes | R | Enum | (0) Off (1) On Def: On |
SSHAccessWlanNetwork | Individual | No | Disables SSH access to the controller via WLAN. | Yes | R | Enum | (0) Off (1) On Def: On |
SSHAccessEth | Individual | No | Disables SSH access to the controller via Ethernet. | Yes | R | Enum | (0) Off (1) On Def: On |
SSHAccessGsm | Individual | No | Disables SSH access to the controller via GSM. | Yes | R | Enum | (0) Off (1) On Def: On |
InvalidRFIDFilter | Both | No | Set whether RFID tags with invalid UIDs shall be filtered out and thus not reported by the reader. | Yes | R/W | Enum | (0) Off (1) On Def: On |
RFIDEnable | Individual | No | Enables or disables the RFID reader. Allows preventing error messages if no reader is installed. | No | R | Enum | (0) Off (1) On Def: On |
EnforcePwdChange | Both | No | Force change of default operator password on login. | No | R | Enum | (0) Off (1) On Def: Off |
EnforceStrongLoginPwds | Both | No | Force selecting a strong secure login password when changing the operator password, the installer password, or the user password. | No | R | Enum | (0) Off (1) On Def: Off |
RFIDMode | Both | No | This parameter determines whether the RFID reader shall just be able to read RFID cards or also shall support NFC communication. If set to 'RFID only' only RFID cards can be read. If set to 'RFID/NFC hybrid' NFC communication is supported and RFID cards can be read. | Yes | R | Enum | (0) RFID only (1) RFID/NFC hybrid Def: RFID only |
EnforceMasterRFID | Both | No | When changing the default operator password the setting of RFID token(s) is forced that reset the system to its operator default settings if presented for 120 seconds. | No | R | Enum | (0) Off (1) On Def: Off |
EnforceSecureRFID | Both | No | This parameter determines whether all RFID cards are accepted to start charging (off) or if only secure RFID token compliant with VDE-AR-E 2532-100 will be accepted (on). | No | R/W | Enum | (0) Off (1) On Def: Off |
ChargeBoxSerialNumber | Individual | No | Overrides the serial number of the charge controller manufacturer. Named 'ChargeBOXSerialNumber' in OCPP BootNotification. Note: It can only be set once if the value is empty! This precondition is met for re-flashed charge controllers. | Yes | R | String | Def: "Not Set" |
ChargePointSerialNumber | Master | No | Set by the charge point manufacturer, not by the controller manufacturer. Sent as 'ChargePointSerialNumber' in OCPP BootNotification. If not set, the OCPP message value is replaced by the 'ChargeBoxIdentity' value. | Yes | R | String | Def: "Not Set" |
MasterRFIDtoReboot | Individual | No | RFID tag to reboot the system if presented for 30 seconds. Disable this feature by leaving this parameter empty. | No | R/W | String | Def: "" |
UserInstallerPasswordCheck | Master | No | No | R/W | uint | [0..4294967295] Def: 1 | |
MasterRFIDstoReset | Individual | No | RFID tokens that reset the system to its operator default settings if presented for 120 seconds. Up to 2 (colon separated) tokens can be defined. To disable this feature leave the input field empty. | No | R/W | String | Def: "" |
SSHClientKey | Master | No | Key for authorizing the user 'root' of the ChargePoint to connect to server via SSH. This authorization can then be used to establish reverse tunnels using customer-specific scripts. | No | R | String | Def: "ssh-rsa AAAAB3NzaC1yc2EAAAADAQABAAABAQCNqOyR/bAsG3s/rcj1ub+Zbeyds7DEP..." |
ErrorsList | Individual | No | List of errors currently present in the ChargePoint. | No | R | String | Def: "No errors" |
ErrorResolution | Individual | No | List of error resolutions currently present in the ChargePoint. | No | R | String | Def: "Error resolution will be displayed for every active error." |
EventsList | Individual | No | List of the last events and errors with their timestamp. | No | R | String | Def: "No events" |
OPKGInstallExtraOption | Both | No | No | R/W | String | Def: "" | |
AuthorizationInputMode | Not relevant | No | Set if the authorization input can just start or it can both start and stop a transaction. Note that Scheidt&Bachmann requires this to be set to Only start. | Yes | R | Enum | (0) Only start (1) Start and stop (2) Only stop (3) Charging while active Def: Only start |
AuthorizationInputType | Not relevant | No | Set if the authorization input switch is normally open or normally closed. Note that Scheidt&Bachmann requires this to be set to Normally open. | Yes | R | Enum | (0) Normally open (1) Normally closed Def: Normally open |
loglevel | Both | No | Level for the logging system. For security reasons you may be asked to re-enter your credentials to download the log. | No | R/W | Enum | (0) LOG_LEVEL_NONE (1) LOG_LEVEL_USER_ERR (2) LOG_LEVEL_USER_WARN (3) LOG_LEVEL_USER_INFO (4) LOG_LEVEL_ERR (5) LOG_LEVEL_WARN (6) LOG_LEVEL_INFO (7) LOG_LEVEL_DBG (8) LOG_LEVEL_VDBG (9) LOG_LEVEL_TRACE Def: LOG_LEVEL_DBG |
loglevelcomponents | Both | No | This parameter allows to set different log levels for different software components. The string entered consists of a comma-separated list of component names and component log levels. A full list of component names is available in the Documentation view. The possible log levels are: TRACE, VDBG, DBG, INFO, WARN, ERR, USER_INFO, USER_WARN, USER_ERR. For example, the string to set log level TRACE for the BACKEND component and log level VDBG for the RCMB component is: BACKEND=TRACE,RCMB=VDBG | No | R/W | String | Def: "" |
GiroEEnable | Individual | No | Enables or disables the GiroCard payment via Giro-e over OCPP. Requires a Giro-e capable OCPP backend. | No | R/W | Enum | (0) Off (1) On Def: Off |
PowerLineVoltage | Individual | No | Single phase RMS voltage of the power source feeding the ChargePoint in Volts. This is used for current calculation from power values from meter. | Yes | R/W | uint | [186..274] Def: 230 |
MasterSlaveMode | Not relevant | No | 'Master' controller handles the backend connection and may start and stop transaction for its slave. 'Slave' controller connects to a master as its backend. Some other parameters are automatically adjusted when turning this on. IMPORTANT NOTE: supported is a setup with 1 master and 1 slave. | Yes | R | Enum | (0) Off (1) Master (2) Slave Def: Off |
LedType | Not relevant | No | Type of LED device connected to the ChargePoint (if any). | No | R | Enum | (0) LED (default) (1) LED ring device (2) LED ring device with RFID always shown (3) LED ring with free charging (7) No LED Def: LED (default) |
DualLedMode | Not relevant | No | Behavior for dual LED boards. When set to 'On', the dual LED board shows independent states of master and slave for the left and right LEDs. 'On Inverted' is the same as 'On' but with master showing slave state and vice versa. When set to 'Off', LEDs operate in clone mode: the left and the right LEDs show the same pattern and colors, presenting the state of the main/master device. | No | R | Enum | (0) Off (1) On (2) On Inverted Def: Off |
DisplayType | Not relevant | No | Type of display connected to the ChargePoint (if any). | No | R | Enum | (0) Display not configured (1) Display not in use (2) Bender LCD-Module DPM2x16FP Def: Display not configured |
DisplayMode | Not relevant | No | Controls the display mode. When set to 'Master/Slave', the display shows independent states for master and slave. When set to 'Main (Master)' the display only presents the state of the main/master device. | No | R | Enum | (0) Main (Master) (1) Master/Slave Def: Main (Master) |
DisplayContentSelectorTime | Not relevant | No | If enabled the display shows charging time information. | No | R | Enum | (0) Off (1) On Def: On |
DisplayContentSelectorEnergy | Not relevant | No | If enabled the display shows charging energy information. | No | R | Enum | (0) Off (1) On Def: On |
DisplayContentSelectorPower | Not relevant | No | If enabled the display shows charging power information. | No | R | Enum | (0) Off (1) On Def: Off |
PatternOnRelayK2 | Not relevant | No | Behavior for the relay 2 (K2), to be used for an external indicator light such as an LED or blinking light. Use option 'On while vehicle connected' for integration with parking management system by Scheidt&Bachmann. To use two contactors in series that are to be controlled separately use option 'On while charging'. | No | R | Enum | (0) Disable (1) On while charging (2) Off while charging (3) On while vehicle connected (S&B) (4) Off while vehicle connected (5) Blink pattern 1 (6) On while Inoperative (7) On while Authorized (8) On while Faulted Def: Disable |
DisplayLanguage | Individual | No | The language of display texts on the LCD display, if available. Only has an effect if a LCD is configured. | No | R/W | Enum | (0) English (1) Deutsch/German (2) Italiano/Italian (3) Slovenský/Slovak (4) Multi-Language EN-DE-FR-NL (5) SR Multi-Language EN-DE-FR-IT Def: Multi-Language EN-DE-FR-NL |
EichrechtState | Individual | No | Eichrecht State | No | R | String | Def: "System without Eichrecht" |
OCPPSchuko | Not relevant | No | Use auxiliary input/output to support additional Schuko Socket | Yes | R | Enum | (0) Disable (1) Enable 'Opto 1 In' Def: Disable |
EOActuatorType | Not relevant | No | Configure the connected actuator type | Yes | R | Enum | (0) Mennekes Standard (2) Phoenix (3) Kuester Gen2 Def: Mennekes Standard |
Type2ContactorLifetime | Individual | No | Maximum number of operating cycles the contactor should be allowed to perform until a replacement is necessary. | Yes | R | uint | [0..100000000] Def: 10000000 |
Type2PlugLifetime | Individual | No | The maximum number of times the plug of the type2 socket can be plugged in safely.. | Yes | R | uint | [0..10000000] Def: 50000 |
SetType2PlugCycles | Individual | No | Use this field when the type2 socket is replaced and the counter for socket cycles must be reset to 0 for a new socket or to a number greater than 0 for a used one. | No | R/W | String | Def: "" |
Type2PlugCounter | Not relevant | No | Number of times the plug of the type2 socket was plugged in. | No | R | String | Def: "39/50,000" |
SetTypeContactorCycles | Individual | No | Use this field when the contactor is replaced and the counter for contactor cycles must be reset to 0 for a new contactor or to a number greater than 0 for a used one. | No | R/W | String | Def: "" |
ContactorCyclesType2 | Individual | No | The number of times the contactor of the type 2 socket was switching on and off. | No | R | String | Def: "7/10,000,000" |
ThresholdContactorCurrentUnderLoad | Individual | No | Set threshold contactor current under load (in Amperes) | Yes | R | uint | [6..80] Def: 6 |
ContactorCyclesUnderloadLimit | Individual | No | The maximum number of contactor cycles under load before receiving a system warning | Yes | R | uint | [0..50000] Def: 6000 |
SetCountContactorCyclesType2UnderLoad | Individual | No | Use this field when the contactor under load is replaced and the counter for contactor cycles must be reset to 0 for a new contactor or to a number greater than 0 for a used one. | No | R/W | String | Def: "" |
GetCountContactorCyclesType2UnderLoad | Individual | No | The number of times the contactor was switching on and off under load. | No | R | String | Def: "0/6,000" |
CableAttached | Not relevant | No | Setting this to on indicates that the charger has a fixed cable attached and does NOT need to lock a cable in a socket. ATTENTION: This is safety relevant! | Yes | R | Enum | (0) Off (1) On Def: Off |
CPDiodeDetection | Individual | No | Set this value to 'On' if you want to check before charging if the diode connected to the control pilot line is connected or not. | No | R/W | Enum | (0) Off (1) On Def: On |
PauseChargingStateD | Both | No | If set to On, charging transactions are paused in case State D is detected. While state D is detected an error is reported to the user. | No | R/W | Enum | (0) Off (1) On Def: Off |
AdcCpCalibrationCfg | Individual | No | This parameter allows to enable the ADC calibration for the control pilot line's states detection. Once calibrated, it is possible to trigger a re-calibration. Note that changes of this parameter require a reboot to take effect. | Yes | R/W | Enum | (0) Off (1) On (2) Recalibrate Def: Off |
CheckCarOverCurrentStopLimit | Both | No | When the charging current reported by the OCPP meter exceeds the signaled current by this percentage, charging will be stopped. | Yes | R/W | uint | [10..100] Def: 30 |
SocketType2State | Individual | No | State of TYPE2 socket at connector 1. | No | R | String | Def: "(A) Vehicle not connected Cable attached AMCC: (-/-/-)" |
SignaledCurrentLimit | Individual | No | Current (in Ampere) that is signaled to the vehicle via PWM. | No | R | String | Def: "0 A" |
HardwareCurrentLimit | Individual | No | Maximum current (in Amperes) the charge point hardware can support | Yes | R | int | [0..80] Def: 16 |
InstallationCurrentLimit | Individual | No | The 'Installation Current Limit' is the upper limit of the 'Operator Current Limit'. It must be below or equal to the 'Maximum Current' of the charge point. This parameter cannot be changed by the backend. | Yes | R | int | [0..80] Def: 16 |
OperatorCurrentLimit | Individual | No | Maximum current (in Amperes) that can be signaled to the vehicle for charging. If the parameter 'Installation Current Limit' exists, the 'Operator Current Limit' must be below or equal to the 'Installation Current Limit'. Otherwise, it must be below or equal to the 'Maximum Current'. It can be freely configured, even while charging. This parameter can be changed by the backend for energy management | No | R/W | int | [0..80] Def: 16 |
FreeCharging | Both | No | Allows charging without authorization via RFID or the backend. Charging is started immediately after a vehicle is connected. | No | R/W | Enum | (0) Off (1) On Def: Off |
CheckCarOverCurrent | Both | No | If set to On the current consumed by the vehicle will be checked against the signaled current. If the overload is above 10% the signaled current will be decreased by 10%. If the overload is above the configured percentage limit the charging will be stopped. | No | R/W | Enum | (0) Off (1) On Def: On |
RandomRestartAfterPowerLoss | Both | No | If this feature is enabled, the restart of charging will be randomized after a power loss. In case of many chargepoints connected to the same power line, this feature avoids a high peak of energy consumption in short period of time, which can result in another blackout. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
PDL_Power | Master | No | PDL Power | No | R/W | String | Def: "" |
EnergyManInputPowerLimitCfg | Individual | No | Enables energy Management from external input | Yes | R/W | Enum | (0) Disable (1) Enable 'Opto 1 In' Def: Disable |
ChargingScheduleAllowedChargingRateUnit | Master | Yes | List of supported quantities for use in a ChargingSchedule. | No | R | String | Def: "Current" |
PhasesConnected | Individual | No | Shows how the number of phases connected to the ChargePoint is configured. | No | R | String | Def: "Three-phase system" |
ASKIoverOCPPAllowedIP | Both | No | Configure a single IP address here that will be allowed to access the 'ASKI over OCPP-S' service. An empty field will allow no access! | Yes | R/W | String | Def: "" |
ConnectorPhaseRotation | Both | Yes | No | R/W | String | Def: "1.RST" | |
ConnectorPhaseRotationIT | Individual | No | No | R/W | String | Def: "L1-L2" | |
ConnectorSwitch3to1PhaseSupported | Master | Yes | If set the ChargePoint supports switching between 3 and 1 phases during a charging session. | Yes | R | bool | [0..1] Def: Off |
SmartChargingUseDisconnectedLimit | Individual | Yes | If enabled and the ChargePoint gets disconnected from the Backend, the 'Disconnected Upper Limit [A] for SmartCharging' will be applied despite the limitations set in stored charging profiles. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
ASKIoverOCPP | Master | No | Enable or disable support for receiving OCPP 1.5 SOAP 'Change Configuration Requests' for the LaMa parameter 'LaMa_ConnectionRate'. The SOAP server will listen on TCP port 13000 for connector 1. 'LaMa_ConnectionRate' can be changed in 10th of Amps. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
EnergyManInputPowerCurrentLim | Individual | No | Single phase RMS current limit (in A) for energy management from external input. Range: from 6 A to 80 A. Set to 0 A to pause charging. | Yes | R/W | uint | [0..80] Def: 16 |
LaMa_ConnectionRate | Individual | No | Secret key for Mennekes EnergyManager Input | No | R/W | uint | [0..100000] Def: 16 |
ConnectorPhaseRotationMaxLength | Individual | Yes | Maximum number of items in a ConnectorPhaseRotation Configuration Key. | No | R | uint | [0..0] Def: 3 |
ChargeProfileMaxStackLevel | Master | Yes | Max StackLevel of a ChargingProfile. | No | R | uint | [0..0] Def: 255 |
ChargingScheduleMaxPeriods | Master | Yes | Maximum number of periods that may be defined per ChargingSchedule. | No | R | uint | [0..0] Def: 255 |
MaxChargingProfilesInstalled | Master | Yes | Maximum number of Charging profiles installed at a time. | No | R | uint | [0..0] Def: 255 |
SmartChargingDisconnectedLimit | Individual | No | Disconnected Upper Limit applied to SmartCharging in case the ChargePoint is disconnected from the backend. | Yes | R/W | uint | [0..999] Def: 16 |
RCDRESET | Individual | No | RCD Reset | No | R/W | Enum | (0) Off (1) On Def: Off |
RCDAUTORECLOSURE | Both | No | Allows to enable the automatic reclosure of the RCD. The auxiliary relay output (on CC612: C3/4, on ICC1324: 23/24) or a dedicated output on ICC1612 is used. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
RCDENABLE | Both | No | Allows to enable RCD detection. It must be Off when there is no RCD connected to the controller. If there is an opto input, it could be used (e. g. C6/5 on CC612). On ICC1324 a lost communication with primary meter because of its power loss could be used. | Yes | R/W | Enum | (0) Off (1) Opto input Def: Off |
SPDCFG | Individual | No | Allows support for Surge Protection Devices (SPD). It must be 'Off' when there is no SPD connected to the controller. | Yes | R/W | Enum | (0) Off (1) On OPTO C6/5 (Normally closed) (2) On OPTO C6/5 (Normally open) Def: Off |
VentHeatingCtrlMode | Both | No | This parameter allows to enable the activation of an external fan or heater according to the housing temperature or vehicle state. | Yes | R/W | Enum | (0) Off (1) Status D (Ventilation Required by vehicle) (2) Charging (Ventilation) (3) Above threshold and charging (Ventilation) (4) Above threshold (Ventilation) (5) Below threshold (Heating) Def: Off |
WeldCheckAuxRelay | Both | No | When enabled, the auxiliary relay will be activated whenever the contactor is welded. If enabled on CC1612 the RCD test pin is not used but instead the selected Ex out output. | No | R/W | Enum | (0) Off (1) Relais 13/14 Def: Off |
MonitoringRelayInput | Individual | No | Use a unique input from a monitoring relay to trigger RCD/MCB. | Yes | R/W | Enum | (0) Disable (2) Enable 'Opto 1 In' (3) Via meter Def: Disable |
RCDAUTORECLOSUREDELAY | Both | No | RCD auto reclosure delay in seconds. | Yes | R/W | uint | [30..1800] Def: 900 |
RCDAUTORECLOSUREATTEMPTS | Both | No | RCD auto reclosure attempts. | Yes | R/W | uint | [1..10] Def: 3 |
VentHeatingHyst | Both | No | This delta in degree (Celsius) allows to add hysteresis to the fan or heater control. In order to switch off the fan/heater the temperature must be below/above the configured temperature threshold plus/minus this delta. | Yes | R | uint | [0..25] Def: 4 |
VentHeatingTempThr | Both | No | Temperature threshold necessary to start or stop the fan or heater. | Yes | R | int | [-40..100] Def: 85 |
AmbientCpuDelta | Individual | No | Temperature delta for measurements from temperature sensor. This value should be tuned according to the thermal characteristics of the charging station. | No | R | uint | [0..150] Def: 23 |
LocalScheduledReboots | Both | No | The local time of day used for house keeping reboots. The charge controller reboots after 30 days to ensure uninterrupted operation. Reboots only occur with no vehicle connected and no customer present. Select a full hour in the range 0 to 23. | Yes | R/W | uint | [0..23] Def: 0 |
DaysScheduledReboots | Both | No | Number of days that is used for house keeping reboots. The charge controller reboots after the number of days to ensure uninterrupted operation. Reboots only occur with no vehicle connected and no customer present. Select a number in range [1..99]. | No | R/W | uint | [1..30] Def: 30 |
ReducedCurrent | Individual | No | Charging current value in Ampere when temperature is above temperature threshold 1. | No | R | uint | [6..80] Def: 16 |
ReducedCurrentPct | Individual | No | How much (in %) of signaled current should be applied to reduce temperature when temperature is above temperature threshold 1. | No | R | uint | [0..100] Def: 100 |
TempDelta | Master | No | Temperature change in degrees Celsius for which a new temperature measurement report is sent to the backend system. A value of 0 switches the reporting off. | No | R | int | [0..50] Def: 5 |
TempStopThreshold2 | Individual | No | Temperature threshold necessary to stop charging. | No | R | int | [40..100] Def: 85 |
TempReduceThreshold1 | Individual | No | Temperature threshold necessary to start decreasing the current. | No | R | int | [40..100] Def: 85 |
MaxTimePerSession | Both | No | Time limit of the session. When Max Time limit is reached, the session is terminated and connector will be unlocked. If Backend is connected, and Time limit is reached, the transaction of the session is sent to backend with status 'SuspendedEV' followed by 'Finishing'. '0' corresponds to 'No limit'. | No | R/W | uint | [0..24] Def: 0 |
InputOutputBackendControlledMode | Both | No | Inputs (InputOptoC65 and InputOptoC87 on CC612 or InputOpto1 and InputOpto2 on others) and output (Output1, and if present, Output2) can be controlled via a backend. | Yes | R | Enum | (0) Off (1) On Def: Off |
InputChangeNotifyBackend | Both | No | Changes on inputs 1 and 2 will issue a status notification message to backend limited to not more then one message every 10 sec. Requires 'Backend controlled mode for inputs and outputs' set to 'On'. | No | R | Enum | (0) Off (1) On Def: Off |
TamperDetectionInputEnable | Individual | No | When enabled, the individual charge controller informs the backend with a status notification that the tamper detection sensor has been triggered. | Yes | R | Enum | (0) Off (1) On Opto1 In (Normally closed) (2) On Opto1 In (Normally open) Def: Off |
DataTransferTariffUsage | Both | No | Enables the DataTransfer messages that allow to show Tariff and Total Usage Information. Beware this feature only works with backend systems that support it. If the backend system does not support it, this will prevent all authorizations from being successful. | No | R/W | Enum | (0) Off (1) On Def: Off |
AuthorizeRemoteTxRequests | Both | Yes | This parameter determines whether a remote request to start a transaction in the form of a RemoteStartTransaction.req message should be authorized beforehand like a local action to start a transaction. Some backends require this as OCPP specification is not clear about this. Other backends are not working if this is parameter is enabled. | Yes | R/W | bool | [0..1] Def: On |
AllowOfflineTxForUnknownId | Both | Yes | This parameter determines whether a client is allowed to charge in case its authorization cannot be processed because the backend is offline or not reachable. If set to 'On', the client is allowed to charge even if it cannot get authenticated from the ocpp whitelist nor from local whitelist. If set to ImmediatelyWhenPlugged, then charging will be allowed in case ChargePoint is offline by just plugging the car and without RFID authorization. If 'Connection Type' is 'No Backend' then this parameter is ignored. | No | R/W | Enum | (0) Off (1) On (2) ImmediatelyWhenPlugged Def: Off |
InfoStatusNotifications | Both | No | This parameter determines whether OCPP status notifications that are meant just for informative purposes (such as a temperature report) should be sent to the backend system or not. | No | R/W | Enum | (0) Off (1) On Def: On |
ErrorStatusNotifications | Both | No | This parameter determines whether OCPP status notifications that are meant to report and error (such as when the plug locking system is broken) should be sent to the backend system or not. | Yes | R/W | Enum | (0) Off (1) On Def: On |
UsbErrorStatusNotifications | Individual | No | This parameter determines whether USB communication errors between master and slave are reported to backend. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
StatusNotificationStrategy | Both | No | This parameter determines on which conditions the ChargePoint changes into the OCCUPIED state. In 'Occupied on Charging' occupied is signaled only when authorization is there and a cable is plugged in. In 'Occupied on 'Authorized/Plugged' the state changes to occupied already when the charger is authorized with nothing connected or when a cable/vehicle is connected but no authorization has taken place yet. | Yes | R/W | Enum | (0) Occupied on Authorized/Plugged (1) Occupied on Charging Def: Occupied on Charging |
DisplayDisconnectAsError | Master | No | Parameter that determines whether an error is signaled to the user when the backend connection is interrupted. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
AuthorizationCacheEnabled | Master | Yes | Enables the use of the internal whitelist for storing RFID UID from the OCPP backend. If disabled, RFIDs even if reported from the backend with an expiry date are not added to an internal cache. | No | R/W | bool | [0..1] Def: On |
idTagLetterCase | Both | No | Parameter that makes the RFID tag management configurable to upper or lower case. | Yes | R/W | Enum | (0) Lower Case (1) Upper Case (2) Lower Case Reversed Byte Order (3) Upper Case Reversed Byte Order Def: Lower Case |
StopTransactionOnEVSideDisconnect | Both | Yes | When set to 'On' the Charge Point will stop a transaction when the cable is unplugged from the EV. | No | R | bool | [0..1] Def: On |
UnlockConnectorOnEVSideDisconnect | Both | Yes | When set to 'On' the Charge Point will unlock the cable on Charge Point side when the cable is unplugged at the EV. | No | R | bool | [0..1] Def: On |
ReserveConnectorZeroSupported | Master | Yes | If set to 'On' the ChargePoint supports reservations on connector 0. | No | R | bool | [0..1] Def: On |
FreeChargingMode | Both | No | Sets the OCPP behavior in free charging mode. Note that in case of a master/slave scenario the slave will be automatically configured to the same mode as used for the master. | Yes | R/W | Enum | (0) No OCPP (1) With OCPP status notif without auth (2) With OCPP status notif with auth (3) With OCPP Full fixed RFID with auth (4) With OCPP Full fixed RFID without auth (5) With OCPP Full any RFID Def: No OCPP |
AllowLongOcppGetConfKeys | Both | No | Allows OCPP keys in get configuration command to be longer than 500 characters. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
OcppGetConfBoolIsInt | Both | No | If activated, boolean OCPP keys are returned as integer values '0' or '1' in command 'GetConfiguration'. This is for compatibility. If not activated, boolean OCPP keys are returned as boolean values 'false' or 'true' in command 'GetConfiguration' according to the OCPP standard. The command 'ChangeConfiguration' accepts both types simultaneously. | No | R/W | bool | [0..1] Def: Off |
StopTransactionOnInvalidId | Individual | Yes | Determines if the ChargePoint will stop an ongoing transaction when it receives a non-Accepted authorization status in a StartTransaction response. | No | R/W | bool | [0..1] Def: On |
ChargeBoxIdentity | Individual | No | ID that is sent to the backend and used by the backend to identify the ChargePoint. | Yes | R/W | String | Def: "+4983900000000001" |
FirmwareVersion | Individual | No | Firmware version running on the ChargePoint. | No | R | String | Def: "5.33.5-21150" |
RCMBVersion | Individual | No | Version of the RCMB module connected to the ChargePoint. | No | R | String | Def: "D0660, V2.01" |
SupportedFeatureProfiles | Master | Yes | List of supported Feature Profiles. Possible profile identifiers: Core, FirmwareManagement, LocalAuthListManagement, Reservation, SmartCharging and RemoteTrigger. | No | R | String | Def: "Core,FirmwareManagement,LocalAuthListManagement,Reservation,SmartChar..." |
RfidTagFreeCharging | Individual | No | RFID Tag for Free Charging with OCPP Full, fixed RFID modes. Note that this RFID Tag is also used when 'If in doubt allow charging' is 'ImmediatelyWhenPlugged' | Yes | R/W | String | Def: "freecharging" |
BackendConnectionTimeout | Master | No | The time in seconds that is used for establishing an APN connection, establishing a Proxy or establishing a backend connection before a timeout will be recognized. Also determines the time period that is waited for answers from the backend for OCPP requests. Only reduce this value to a smaller value if you can assure a stable network connection. Increase the value to a larger value in case of bad network coverage. Increasing the value will result in longer user interaction delays. | Yes | R/W | uint | [3..300] Def: 60 |
ConnectionTimeOut | Both | Yes | Interval (from successful authorization) until incipient charging session is automatically canceled due to failure of the EV user to correctly insert the charging cable connector(s) into the appropriate connector(s). | Yes | R/W | uint | [4..300] Def: 45 |
NumberOfConnectors | Master | Yes | Number of physical charging connectors of this Charge Point. | No | R | uint | [0..0] Def: 1 |
GetConfigurationMaxKeys | Master | Yes | Maximum number of requested configuration keys in a GetConfiguration.req PDU. | No | R | uint | [0..0] Def: 352 |
TransactionMessageAttempts | Individual | Yes | Sets how often the ChargePoint tries to submit a transaction-related message when the backend fails to process it. 0 means infinite attempts. | Yes | R/W | uint | [0..5] Def: 5 |
EichrechtTransactionMessageAttempts | Individual | No | Sets how often the ChargePoint tries to submit an Eichrecht transaction-related message when the backend fails to process it. 0 means infinite attempts. -1 means that the value of the OCPP-key "TransactionMessageAttempts" should be used. | Yes | R/W | int | [-1..5] Def: 0 |
TransactionMessageRetryInterval | Individual | Yes | Sets how long the ChargePoint will wait before resubmitting a transaction-related message that the backend failed to process. | Yes | R/W | uint | [0..1000] Def: 0 |
ResetRetries | Individual | Yes | Number of times to retry an unsuccessful reset of the ChargePoint. | Yes | R/W | uint | [0..100] Def: 100 |
OcppQueueFullAsErrorState | Both | No | When set, a full OCPP message queue will cause an error state. Charging will be terminated. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
LocalPreAuthorize | Master | Yes | Sets if the Charge Point, when online, will start transactions for locally authorized identifiers without requesting an Authorize.conf from the Central System. | No | R/W | bool | [0..1] Def: On |
LocalAuthorizeOffline | Master | Yes | Sets if the Charge Point, when offline, will start transactions for locally authorized identifiers. | No | R/W | bool | [0..1] Def: On |
ForceHeartbeatRequestMessages | Not relevant | No | Sets if the Charge Point should send OCPP Heartbeat request messages despite other messages being sent. | Yes | R/W | Enum | (0) Off (1) On Def: On |
RetransmitMeterValues | Both | No | If enabled, MeterValue messages are retransmitted on errors. | No | R/W | Enum | (0) Off (1) On Def: On |
UPnPUUID | Individual | No | The UPnP UUID that this ChargePoint uses when announcing its presence on the local network. Only used if connected to a local network. | Yes | R | String | Def: "12b3074f-5f49-4368-b4d7-fe2ae0663b1c" |
HeartbeatInterval | Master | Yes | The interval in seconds with which OCPP heartbeat messages are sent to the backend system. Modifying this parameter may upset the backend system (OCPP 1.6). | No | R/W | int | [10..86400] Def: 240 |
StopTransactionModeUnplug | Both | No | This allows to modify the behavior of the charger at the end of a transaction. Normal unlocks and stops the transaction, when the plug is removed from the vehicle or the RFID used for authorization is used again. Stop after unplugging causes a transaction to be fully stopped only when the cable is pulled from the socket of the charging station. Only by RFID/Remote Stop only unlocks if RFID or a backend message is used for stopping the transaction. Pulling the cable out of the car will not end the transaction. | Yes | R/W | Enum | (0) Normal (1) Stop only by unplugging (2) Unlock only by RFID/RemoteStop (3) Normal + Mode D Def: Normal |
SupportedFileTransferProtocols | Master | Yes | List of supported file transfer protocols: FTP, FTPS, SCP, HTTP and HTTPS | No | R | String | Def: "FTP, FTPS, SCP, HTTP, HTTPS" |
LightIntensity | Both | Yes | Value range is 0 to 100 | No | R/W | uint | [0..100] Def: 100 |
StatusNotificationWebuiLogin | Both | No | Status notification will be sent to backend in case of login success/failure for webui. | No | R/W | Enum | (0) Off (1) On Def: Off |
USBFieldEngineer | Both | No | Allow getting diagnostics and configuration of the ChargePoint via USB stick. | Yes | R/W | Enum | (0) Off (1) On Def: On |
USBConfigUpdate | Both | No | Allow update of the charge point configuration via USB stick. | Yes | R/W | Enum | (0) Off (1) On Def: On |
USBFirmwareUpdate | Both | No | Allow update of the charge point firmware via USB stick. | Yes | R/W | Enum | (0) Off (1) On Def: On |
LocalAuthListEnabled | Master | Yes | Selects if the Local Authorization List is enabled | No | R/W | bool | [0..1] Def: Off |
LocalAuthListMaxLength | Master | Yes | Maximum number of identifications that can be stored in the Local Authorization List | No | R | uint | [0..1000000] Def: 1000000 |
SendLocalListMaxLength | Master | Yes | Maximum number of identifications that can be send in a single SendLocalList.req | No | R/W | uint | [0..45000] Def: 45000 |
fll | Master | No | Local whitelist of RFIDs independent of a backend connection. | No | R/W | Enum | (0) Off (1) On Def: Off |
fllUseOcppStartStop | Both | No | Send OCPP Start/Stop transaction for authorizations from the local white list. | No | R/W | Enum | (0) Off (1) On Def: On |
ConnectionType | Master | No | The type of data connection used to connect to the backend system. Choose 'No Backend' to disable backend communication completely. While using GSM the wallbox can be connected to LAN/WLAN at the same time. | Yes | R/W | Enum | (0) No Backend (1) GSM (2) Ethernet (3) USB (4) WLAN Def: No Backend |
DataConsumption | Master | No | Data Consumption (in bytes) for the running month. | No | R/W | uint | [0..9223372036854775807] Def: 0 |
DataConsumptionLastMonth | Master | No | Data Consumption (in bytes) for the previous month. | No | R/W | uint | [0..9223372036854775807] Def: 0 |
InterfacesList | Master | No | List of interfaces and their IPs | No | R | String | Def: "eth0: [E0:AE:B2:02:E9:8F] IP: 10.13.208.20 (ocpp)" |
APN | Master | No | Access Point Name of the mobile network to be used when establishing connections to the backend system via the built-in modem. | Yes | R/W | String | Def: "" |
ModemNetworkSelMode | Master | No | In 'Automatic' mode the modem chooses the operator. In 'Manual' mode the operator specified in requested operator name is used. In 'Manual/Auto' mode the automatic mode is used if manual selection fails. | Yes | R/W | Enum | (0) Auto (1) Manual (2) Manual/Auto Def: Auto |
ModemNetworkType | Master | No | The technology to be used to access the network 2G (GSM), 3G (UTRAN) or 4G (LTE). In auto mode the modem will choose the technology. | Yes | R/W | Enum | (0) Auto (1) 2G (2) 3G (3) 4G Def: Auto |
ModemNetworkOperFmt | Master | No | Indicates if the operator name format is alphanumeric or numeric. Long alphanumeric format can be up to 16 characters and short format up to 8 characters (refer to GSM MoU SE.13). | Yes | R/W | Enum | (0) Alphanumeric Long (1) Alphanumeric Short (2) Numeric Def: Alphanumeric Short |
ScanNetworkOperators | Master | No | Determines whether a search for available network operators is carried out upon boot. Set the 'Scan network operators at boot' parameter to 'On', then click on 'Save & Restart'. After boot the state page will show all the available operator names. The value is automatically set to 'Off' again after boot. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
APNUsername | Master | No | Username to be used for authenticating with the Access Point of the mobile network for connecting with the backend system. | Yes | R/W | String | Def: "" |
APNPassword | Master | No | Password to be used for authenticating with the Access Point of the mobile network for connecting with the backend system. | Yes | R/W | String | Def: "" |
Req3GNetworkOperator | Master | No | The name of the network operator to be used in manual 'Network selection mode'. | Yes | R/W | String | Def: "" |
SIMPIN | Master | No | PIN number that should be used to unlock the SIM card. This number is only used if the SIM card requires a PIN number. | Yes | R/W | String | Def: "" |
LASTWRONGSIMPIN | Master | No | The wrong PIN number that was used last time. | Yes | R/W | String | Def: "" |
GSMPPPMTU | Master | No | Maximum transmission unit size for GSM connections (in bytes)(valid value range: 68 - 1492). | Yes | R/W | String | Def: "" |
ModemNetworkState | Master | No | The current network registration mode of the modem which informs about the technology (2G, 3G, 4G) and about the registration (home network, roaming...) | No | R | Enum | (0) Disable (1) Enable (2) Enable with location (3) Not Available Def: Not Available |
OperatorSelectionMode | Master | No | Operator Selection Mode, Auto or Manual... | No | R | Enum | (0) Automatic (1) Manual (2) Deregister from network (3) Set Only (4) Manual/Automatic (5) Not Available Def: Not Available |
GSMState | Master | No | Registration state to the mobile network. | No | R | Enum | (0) Not Registered and Not Searching (1) Registered at Home Network (2) Not Registered and Searching (3) Registration Denied (4) Unknown (5) Registered (Roaming) (6) Not Available Def: Not Available |
IMSI | Master | No | International Mobile Subscriber Identity (IMSI), a value associated with the SIM card inserted into the built-in modem. If this number is properly read the SIM card is inserted correctly and can be read by the built-in modem. | No | R | String | Def: "" |
IMEI | Master | No | International Mobile Equipment Identification (IMEI). A number associated with the hardware of the built-in modem. If this number is present this device has a built-in modem and can properly communicate with the modem. | No | R | String | Def: "" |
ICCID | Master | No | Integrated Circuit Card Identifier (ICCID) of the SIM card inserted into the built-in modem. | No | R | String | Def: "" |
LAI | Master | No | Location Area Identity (LAI), composed of Mobile Country Code (MCC), Mobile Network Code (MNC) and Location Area Code (LAC). | No | R | String | Def: "" |
Used3GNetworkOperator | Master | No | Name of the network operator the built-in modem is currently connected to. | No | R | String | Def: "" |
AvailableNetworks | Master | No | List of network operators that are available and visible using the currently selected antenna. This value is only properly filled if requested via the 'Scan network operators at boot' configuration parameter. | No | R | String | Def: "" |
MODEMNETSTATE | Master | No | Show at which state in the connection sequence the modem is currently operating. Show OK when connected. Additionally, APN session duration and traffic are shown. | No | R | String | Def: "Not available" |
ModemInfo | Master | No | Shows the modem manufacturer, model and firmware revision. | No | R | String | Def: "Not available" |
ModemAccessTechnology | Master | No | Shows which access technology (2G, 3G, 4G) the modem is currently using. | No | R | String | Def: "" |
ModemLastConnError | Master | No | Reason for the last modem APN connection failure | No | R | String | Def: "" |
RSSI | Master | No | Received Signal Strength Indicator as reported by the modem. This parameter is an indication how well the built-in modem can receive signals from the base station. | No | R | String | Def: "0 (Extremely low)" |
MCC | Master | No | Mobile Country Code as determined from the SIM card. This tells you which country your SIM card comes from. | No | R | uint | [0..0] Def: 4294967295 |
MNC | Master | No | Mobile Network Code as determined from the SIM card. This tells you which mobile network operator your SIM card comes from. | No | R | uint | [0..0] Def: 4294967295 |
LAC | Master | No | Location Area Code as reported by the built-in modem, this value can be used to determine the location of the ChargePoint. | No | R | uint | [0..0] Def: 4294967295 |
CellID | Master | No | Cell ID as reported by the built-in modem, this value can be used to determine the location of the ChargePoint more accurately. | No | R | uint | [0..0] Def: 4294967295 |
GSMStateInfo | Master | No | Status of the GSM connection such as APN name, network type (LTE, EDGE), frequency/band (e.g. band 7, band 20), signal strength (RSSI) and signal quality (SINR). | No | R | String | Def: "Unknown APN (Not Available |
NetworkConfigMode | Master | No | Mode for ethernet configuration to be used for the ChargePoint. 'Auto' uses DHCP to configure the ChargePoint's ethernet connection; 'Static' uses the addresses as filled in static network configuration IP; 'DHCP server' assigns a predefined DHCP configuration to other DHCP clients in the same network (range 172.16.23.100-172.16.23.254]; netmask 255.255.255.0; gateway 172.16.23.1; DNS 172.16.23.1). The DHCP server's own IP is 172.16.23.1. Any static network configuration is ignored in case of DHCP server mode. Please consider to switch the 'WAN router' on if the DHCP server is enabled. | Yes | R/W | Enum | (0) Auto (DHCP client) (1) Static (2) DHCP server Def: Auto (DHCP client) |
StaticNetworkConfigAddress | Master | No | Static LAN IP of the ChargePoint. | Yes | R/W | String | Def: "192.168.0.100" |
StaticNetworkConfigNetmask | Master | No | Netmask to use for the LAN of the ChargePoint. | Yes | R/W | String | Def: "255.255.255.0" |
StaticNetworkConfigDNS | Master | No | DNS server to use for the LAN of the ChargePoint. | Yes | R/W | String | Def: "8.8.8.8" |
SSLModeClient | Master | No | Allows to set how strict SSL authentication is, from no authentication (encryption only) to full authentication. | Yes | R/W | Enum | (0) Normal SSL Auth (1) Allow expired certificate (2) Skip host check (3) Allow expired certificate and skip host check (4) Encrypt only - No authentication Def: Encrypt only - No authentication |
WANRouterInterface | Master | No | Selects the WAN (GSM/Ethernet/WLAN) interface. | Yes | R/W | Enum | (0) GSM Def: GSM |
WANRouter | Master | No | Enables access from LAN interfaces to the selected WAN (GSM/Ethernet/WLAN) interface. This will also enable the DNS forwarder. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
OCPPMode | Master | No | This parameter determines whether backend communication is done using the standard OCPP JSON variant or the proprietary Binary OCPP variant of Ebee Smart Technologies. The Binary OCPP variant is working across NAT networks and therefore does not require a private APN for remote messages to arrive at the charge point. Also Binary OCPP uses much less data (factor 20 to 50) than standard OCPP. Binary OCPP however requires a Binary OCPP proxy on the backend side. | Yes | R/W | Enum | (0) OCPP-J 1.6 (2) OCPP-B 1.5 (3) OCPP-B 1.6 Def: OCPP-J 1.6 |
ConnSettingsFallback | Individual | No | Restores last good connection settings when failed to reconnect to the backend after a reboot. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
HostnameBinaryOCPP | Master | No | The DNS hostname or IP address of the binary ocpp proxy server for the backend system. This parameter is only used if Binary OCPP is selected for the TCP/IP mode. | Yes | R/W | String | Def: "be.elinc.de" |
OCPPBackendJSONURL | Master | No | The WS/WSS URL of the OCPP backend system. This URL must be the WS/JSON endpoint and begin with "ws://" or "wss://". This parameter is only used if OCPP-J 1.6 or OCPP-J 2.0 mode is used. The ChargePoint's ID gets automatically appended when connecting to the backend. | Yes | R/W | String | Def: "ws://be.elinc.de:8080/OCPPJProxyQA/v16/" |
WebsocketsProxyURL | Master | No | Specify the websockets proxy to connect to in the format HOST:PORT, whereby PORT is optional and set to 80 when not specified. | Yes | R/W | String | Def: "" |
HTTPBasicAuthPassword | Master | No | The password to be used for HTTP Basic Authorization. If left empty, HTTP Basic Authorization is not used. | Yes | R/W | String | Def: "" |
OcppCertificate | Master | No | Certificate used for SSL connections to the backend. | No | R/W | String | Def: "" |
OcppCSR | Master | No | Certificate signing request (for OCPP) in PEM format that corresponds to the private key this charge point generated upon provisioning. | No | R | String | Def: "-----BEGIN CERTIFICATE REQUEST-----MIIBFjCBvAIBAjBaMRAwDgYDVQQDDAdaW..." |
OcppUserCaCertificate | Master | No | User CA Certificate (OCPP). | No | R/W | String | Def: "" |
NetworkConfigHostname | Master | No | Network hostname used for DHCP and mDNS. | Yes | R/W | String | Def: "" |
StaticNetworkConfigGateway | Master | No | Gateway to use for the LAN of the ChargePoint. | Yes | R/W | String | Def: "192.168.0.1" |
PortBinaryOCPP | Master | No | TCP port of the proxy server for binary OCPP communication with the backend. | Yes | R/W | uint | [1..65535] Def: 444 |
RegenerateOcppCertAndKey | Master | No | Trigger Regeneration of Private Key and Self Signed Certificate for OCPP. | No | R/W | String | Def: "" |
TcpWatchdogTimeout | Individual | No | This is the time in seconds in which the connection to the backend can be not working until the system reboots. Set it to 0 to disable rebooting. | Yes | R/W | uint | [0..100000] Def: 10800 |
NetworkConfigDHCPRetries | Master | No | DHCP request number of retries before giving up. | Yes | R/W | uint | [0..100000] Def: 10 |
NetworkConfigDHCPTimeout | Master | No | DHCP request timeout in seconds. | Yes | R/W | uint | [0..100000] Def: 10 |
NetworkConfigDHCPDelay | Master | No | DHCP request delay between multiple requests in seconds. | Yes | R/W | uint | [0..100000] Def: 10 |
WebSocketPingInterval | Master | Yes | WebSockets keep-alive interval in seconds or 0 when unused. Using keep-alive on WebSockets layer is especially useful when using a NAT router between ChargePoint and backend. The ping-pong being sent prevents the NAT router from closing the websockets connection. | No | R/W | uint | [0..100000] Def: 0 |
OcppConStrictTls | Master | No | If 'All ciphers' is selected, all recent TLS versions will be accepted. For 'Only secure ciphers' any OCPP connection will be forced to connect only via TLS 1.2 or higher and secure ciphers. Lower versions or weak ciphers will be refused. This is the most secure option currently. | Yes | R/W | Enum | (0) All ciphers (1) Only secure ciphers Def: All ciphers |
WLANSSID | Master | No | SSID of the WLAN the ChargePoint tries to connect to. | No | R/W | String | Def: "" |
WLANPassword | Master | No | Password of the WLAN the ChargePoint connectsto. The Chargepoint automatically chooses thecorrect encryption method of the WLAN. | No | R/W | String | Def: "" |
WLANStaticNetworkConfigAddress | Master | No | Static WLAN IP of the ChargePoint. | Yes | R/W | String | Def: "192.168.1.100" |
WLANStaticNetworkConfigNetmask | Master | No | Netmask to use for the WLAN of the ChargePoint. | Yes | R/W | String | Def: "255.255.255.0" |
WLANStaticNetworkConfigGateway | Master | No | Gateway to use for the WLAN of the ChargePoint. | Yes | R/W | String | Def: "192.168.1.1" |
WLANStaticNetworkConfigDNS | Master | No | DNS server to use for the WLAN of the ChargePoint. | Yes | R/W | String | Def: "8.8.8.8" |
WLANEnabled | Master | No | Enable or disable WLAN. | No | R/W | Enum | (0) Off (1) On Def: On |
WLANNetworkConfigMode | Master | No | Network configuration mode for the ChargePoint's WLAN connection. Set to 'Auto' to use DHCP to configure the WLAN network connection automatically. Use 'Static' to use a static IP address to be configured below (as well as a netmask, gateway, and DNS server). | Yes | R/W | Enum | (0) Auto (DHCP client) (1) Static Def: Auto (DHCP client) |
WLANNetworkConfigDHCPRetries | Master | No | Number of DHCP requests sent before giving up on the DHCP server. | No | R/W | uint | [0..100000] Def: 10 |
WLANNetworkConfigDHCPTimeout | Master | No | DHCP request timeout in seconds. | No | R/W | uint | [0..100000] Def: 10 |
WLANNetworkConfigDHCPDelay | Master | No | DHCP request delay (in seconds) between multiple requests . | No | R/W | uint | [0..100000] Def: 10 |
TcpdumpInterface | Individual | No | The type of interface we want to dump packet data into file. Choose 'Any' to listen on any network interface. | No | R/W | Enum | (1) Backend Host (0) Any (3) GSM (2) Ethernet (4) USB (5) WLAN Def: Any |
Tcpdump | Individual | No | Switch 'tcpdump' on or off for dumping packets data at the configured interface into the log file 'packets.pcap0'. Note: 'tcpdump' will log 20 MB data at most and switch off on its own. The log data file may be retrieved via the 'Download Log Files' function. A running 'tcpdump' will be stopped before. | No | R/W | Enum | (0) Off (1) On Def: Off |
Config15118 | Both | No | High Level (15118 protocol) Power Line Communication configuration. If set to 'Off' 15118 communication is disabled. If set to 'On (With PlugNCharge)' 15118 communication is enabled and plug and charge is supported. If set to 'On (No PlugNCharge)' 15118 communication is enabled but plug and charge is not supported. Configuration is only possible if output used for phase switching relay is set to 'Off'. | Yes | R/W | Enum | (0) Off (1) On (with PlugNCharge) (2) On (no PlugNCharge) Def: Off |
SeccCertExpireDate15118 | Individual | No | Supply Equipment Charge Controller Certificate expiry date. This is the expiry date of the certificate for the secure TLS communication with the car via power line communication (15118 protocol). | No | R | String | Def: "Not Available" |
Log15118 | Both | No | Enable the creation of the '15118_log.csv' file with the input and output exi stream messages. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
MACEVCCIDPrefix | Both | No | This prefix will be inserted in the EV's MAC address when used as authorization ID against the backend or local whitelist for autocharge. | Yes | R/W | String | Def: "" |
EVMACAddr | Individual | No | EV's MAC address. | No | R | String | Def: "" |
autochargeid | Both | No | This ID will be used for authorization in case the EV failed to communicate with the EVSE or does not support autocharge. | Yes | R/W | String | Def: "autochargeid" |
Autocharge | Both | No | Autocharge is an experimental and non-standard feature. Some vehicles may not work or show a charging error. The feature is improved continuously both on EVSE and EV side. Check if software updates are available to make use of improvements. If set to 'On (Fixed ID)' an autorization request will be done for the configured autocharge fixed ID in case the EV failed to communicate with the EVSE or does not support autocharge. | Yes | R/W | Enum | (0) Off (1) On (2) On (Fixed ID) Def: Off |
DepartureTime | Individual | No | Used to indicate when the vehicle intends to finish the charging process. | No | R | String | Def: "Not Available" |
EAmount | Individual | No | Amount of energy reflecting the EV's estimate of how much energy is needed to fulfill the user configured charging goal for the current charging session. This might include energy for other purposes than solely charging the HV battery of an EV. | No | R | String | Def: "Not Available" |
EVSEMaxCur | Individual | No | Value sent to the EV on Charging Status messages during the charging loop. | No | R | String | Def: "Not Available" |
SeccLeafSubjectCommonName | Both | No | Common Name of the SECC leaf certificate(s). It must be a SECCID. | No | R/W | String | Def: "DE-EBE-S-CHANGEME0000000000000000000000000000001" |
SeccLeafSubjectCountry | Both | No | Country of the SECC (EVSE) leaf certificate. Indicates in which country the CPO operates. Example: DE | No | R/W | String | Def: "DE" |
SeccLeafSubjectOrganization | Both | No | Organization of the SECC (EVSE) leaf certificate. Indicates which CPO operates this EVSE. Example: Hubject GmbH | No | R/W | String | Def: "Bender GmbH Co. KG" |
ConnectorEvseIds | Both | No | Comma separated EVSEIDs for OCPP connectors starting with connector 1 in one string. | Yes | R/W | String | Def: "" |
CertificateStoreMaxLength | Both | Yes | Maximum number of Root/CA certificates that can be installed in the Charge Point. | Yes | R | uint | [0..50] Def: 50 |
CentralContractValidationAllowed | Both | Yes | If this variable is true, then the contract certificate and chain will be sent to the server for validation and authorization. Otherwise, the certificate will be validated by the Charge Point and only the certificate's OCSP information will be sent to the server. | Yes | R/W | bool | [0..1] Def: On |
ContractValidationOffline | Both | Yes | If this variable is true, then the Charge Point will try to validate a contract certificate when it is offline. | Yes | R/W | bool | [0..1] Def: On |
ISO15118PnCEnabled | Both | Yes | If this variable set to true, then the Charge Point supports ISO 15118 plug and charge messages via the DataTransfer mechanism as described in the OCA OCPP 1.6 extension document. | No | R/W | bool | [0..1] Def: Off |
P15118ConStrictTls | Master | No | If 'Standard' is selected, any 15118 connection will be forced to connect only via TLS 1.2 or higher and secure ciphers according standard. Lower versions or weak ciphers will be refused. This is the most secure option currently. For 'All ciphers' all recent TLS versions and ciphers will be accepted. This should be used only to solve compatibility issues. | Yes | R/W | Enum | (0) All ciphers (1) Standard Def: Standard |
P15118EVSlacReqTimeout | Both | No | This time indicates how long the EVSE should signal 5% to wait for EV SLAC requests. When this timeout expires, it is assumed the EV does not support 15118 nor autocharge and nominal PWM is signaled if already authorized. This parameter is relevant only if 15118 or Autocharge are enabled. | Yes | R/W | int | [1..50] Def: 7 |
OCPPMeterType | Individual | No | Type of meter used for the charging socket and its connector. This is relevant for OCPP transactions. For Modbus/RTU meters the address must be 1. | Yes | R | Enum | (73) eHZ Meter via USB (75) eHZ-B Meter via USB (6) Modbus Meter ABB (47) Modbus ABB EV3 (44) Modbus Berg B23 (43) Modbus Berg BME 461 (19) Modbus TQ EM300-LR (41) Modbus TQ EM410/EM420 (25) Modbus TQ EM300-LR (TCP) (42) Modbus TQ EM410/EM420 (TCP) (81) Modbus IPD Control (TCP) (86) Modbus Meter Carlo Gavazzi EM111/112 (20) Modbus Meter Carlo Gavazzi EM200 (29) Modbus Meter Carlo Gavazzi EM210 (21) Modbus Meter Carlo Gavazzi EM340 (37) Modbus DZG DVH4013 (7) Modbus Meter Eastron SDM630 (58) Modbus Eastron SDM230 (8) Modbus Eastron SDM120_220 (39) Modbus Eastron SDM72D (68) Modbus Eastron SDM72D-M-V2 (32) Modbus ECS M3PRO (54) Modbus ECS M3PRO (TCP) (13) Modbus Meter Finder (12) Modbus Meter Garo EM270 (10) Modbus Meter Garo GNM1D (9) Modbus Meter Garo GNM3D (22) Modbus Meter Garo GNM3T (28) Modbus Meter Garo GNM3TD (11) Modbus Meter Garo GM3T (80) Modbus Meter Garo GMI3D-LP (38) Modbus Gossen Metrawatt EM2289 (27) Modbus Hager ECR380D (23) Modbus IME CE4DMID31 (87) Modbus IME CE4DF3DTMID (15) Modbus Inepro PRO1_2 (16) Modbus Inepro PRO380 (84) Modbus Wago 879-3000 (40) Modbus Iskra WM3M6 (78) Modbus Iskra IE38M (79) Modbus Meter Finder 7M38 (33) Modbus Janitza UMG 512/96 PRO (34) Modbus Janitza UMG 512/96 PRO (TCP) (85) Modbus Janitza UMG 604 PRO (TCP) (35) Modbus Janitza UMG 605 PRO (36) Modbus Janitza UMG 605 PRO (TCP) (64) Modbus NZR EcoCount S85/SL85 (17) Modbus Optec (45) Modbus Phoenix Contact EEM-EM357 (30) Modbus Phoenix Contact EEM-MB371 (TCP) (14) Modbus Saia ALE3 (83) Modbus Schneider Generic (TCP) (82) Modbus Schneider Generic (31) Modbus Schneider iEM3555 (26) Modbus Siemens 7KM2200 (TCP) (24) Modbus Siemens 7KT1666 (49) Modbus YTL DTS353F (50) EV Optimizer (53) Modbus SELEC EM2M-1P-C-100A (55) Modbus Lovato DMED 301 (56) Modbus Eetarp GEM630 (57) Modbus Eetarp GEM230 (65) Modbus DZG DWH4113 (66) Modbus ABB D1M (67) Modbus ABB D1M (TCP) (60) ER Eastron SDM630-EV (61) ER NZR EcoCount SL+SC 85 (63) ER NZR EcoCount SL+S 85 (62) ER Iskra WM3M4C (69) ER EMH iML (1) S0 Meter 'Opto 1 In' (72) Modbus Eichrecht (3) No Meter Def: No Meter |
SecondMeterType | Master | No | Energy Management: the type of second meter used only for input to manage the current on the grid. For Modbus/RTU meters the address must be 2. | Yes | R/W | Enum | (77) WiMOD IR Reader USB stick (6) Modbus Meter ABB (47) Modbus ABB EV3 (44) Modbus Berg B23 (43) Modbus Berg BME 461 (19) Modbus TQ EM300-LR (25) Modbus TQ EM300-LR (TCP) (41) Modbus TQ EM410/EM420 (42) Modbus TQ EM410/EM420 (TCP) (81) Modbus IPD Control (TCP) (86) Modbus Meter Carlo Gavazzi EM111/112 (20) Modbus Meter Carlo Gavazzi EM200 (29) Modbus Meter Carlo Gavazzi EM210 (21) Modbus Meter Carlo Gavazzi EM340 (7) Modbus Meter Eastron SDM630 (58) Modbus Eastron SDM230 (8) Modbus Eastron SDM120_220 (39) Modbus Eastron SDM72D (68) Modbus Eastron SDM72D-M-V2 (32) Modbus ECS M3PRO (54) Modbus ECS M3PRO (TCP) (13) Modbus Meter Finder (12) Modbus Meter Garo EM270 (10) Modbus Meter Garo GNM1D (9) Modbus Meter Garo GNM3D (22) Modbus Meter Garo GNM3T (28) Modbus Meter Garo GNM3TD (11) Modbus Meter Garo GM3T (80) Modbus Meter Garo GMI3D-LP (27) Modbus Hager ECR380D (23) Modbus IME CE4DMID31 (87) Modbus IME CE4DF3DTMID (15) Modbus Inepro PRO1_2 (16) Modbus Inepro PRO380 (84) Modbus Wago 879-3000 (40) Modbus Iskra WM3M6 (78) Modbus Iskra IE38M (79) Modbus Meter Finder 7M38 (33) Modbus Janitza UMG 512/96 PRO (34) Modbus Janitza UMG 512/96 PRO (TCP) (85) Modbus Janitza UMG 604 PRO (TCP) (35) Modbus Janitza UMG 605 PRO (36) Modbus Janitza UMG 605 PRO (TCP) (64) Modbus NZR EcoCount S85/SL85 (17) Modbus Optec (45) Modbus Phoenix Contact EEM-EM357 (30) Modbus Phoenix Contact EEM-MB371 (TCP) (14) Modbus Saia ALE3 (83) Modbus Schneider Generic (TCP) (82) Modbus Schneider Generic (31) Modbus Schneider iEM3555 (26) Modbus Siemens 7KM2200 (TCP) (24) Modbus Siemens 7KT1666 (49) Modbus YTL DTS353F (51) Modbus Sunspec Meter (52) Modbus Sunspec Meter (TCP) (50) EV Optimizer (53) Modbus SELEC EM2M-1P-C-100A (55) Modbus Lovato DMED 301 (56) Modbus Eetarp GEM630 (57) Modbus Eetarp GEM230 (59) Modbus Temco Controls SPM1-XX0-AC (88) SMA Commercial Energy Meter (TCP) (66) Modbus ABB D1M (67) Modbus ABB D1M (TCP) (1) S0 Meter 'Opto 1 In' (3) No Meter Def: No Meter |
OCPPViaLocalNetwork | Both | No | If 'On' is selected, the minimum value of parameter 'Meter Value Sample Interval (OCPP)' is reduced from '10' to '1'. | No | R/W | Enum | (0) Off (1) On Def: Off |
MeterValueSampleInterval | Both | Yes | Interval in seconds after which a new meter value is sent to the backend system during a charging transaction. Set 0 to turn off or to a value greater than or equal to 10 to turn on. | No | R/W | uint | [0..99999] Def: 0 |
MeterValueSampleMode | Both | No | According to the mode, meter values are sent under specific circumstances. 'WholeTransaction': only while transaction is active. 'ContactorClosed': only when contactor is closed.'CurrentFlowOnly': only when current is flowing to vehicle. | No | R/W | Enum | (0) Whole transaction (1) Contactor closed (2) Current flow only Def: Whole transaction |
ClockAlignedDataInterval | Both | Yes | Interval in seconds after which a new meter value is sent to the backend system regardless of whether a charging transaction is ongoing or not. The sending of these values is aligned with the full hour. Set it to 0 to turn off or a value of 10 or greater to turn on. | Yes | R/W | uint | [0..4294967295] Def: 0 |
ClockAlignedMeterRandomSendDelay | Both | No | The sending of the clock aligned values are delayed for a random time between 0 and the configured value. In case of large number of chargers, this can prevent backend problems on handling many messages at the same time. | Yes | R/W | uint | [0..4294967295] Def: 10 |
MeterValuesAlignedData | Both | Yes | Comma-separated list of types of meter values that should be sent as clock aligned data elements in separate meter values messages. Supported are: 'Energy.Active.Import.Register', 'Power.Active.Import', 'Current.Import', 'Current.Offered', 'Voltage', 'Soc', 'Frequency', and 'Temperature'. | No | R/W | String | Def: "Energy.Active.Import.Register" |
MeterValuesSampledData | Both | Yes | Comma-separated list of types of meter values that should be sent as sampled data elements in separate meter value messages. Supported are: 'Energy.Active.Import.Register', 'Power.Active.Import', 'Power.Offered', 'Current.Import', 'Current.Offered', 'Frequency', 'SoC', and 'Temperature'. | No | R/W | String | Def: "Energy.Active.Import.Register" |
StopTxnSampledData | Both | Yes | Not supported (included for compatibility). | No | R/W | String | Def: "" |
StopTxnAlignedData | Both | Yes | Not supported (included for compatibility). | No | R/W | String | Def: "" |
SecondMeterIPAddress | Master | No | Sets the IP address of the second meter. | Yes | R/W | String | Def: "" |
SecondMeterTCPPortNumber | Master | No | Specifies the TCP port of the second meter. | Yes | R/W | uint | [0..65535] Def: 502 |
MeterRestrictSecondaryTypes | Not relevant | No | Show complete list with all meter types for load management or limit list to meter models with Modbus TCP. | Yes | R | Enum | (0) All meter types (1) Modbus TCP meters only Def: All meter types |
RestartTransAfterPowerLoss | Both | No | Enable if a transaction that was interrupted by a power loss shall be continued once the power is restored. If disabled the authorization needs to be done again by the user and a new transaction will be started. Can't be enabled if sending signed meter values is enabled. | Yes | R/W | Enum | (0) Off (1) On (2) On (BYES specific) Def: Off |
CurrentDirSecondL1 | Individual | No | If set to 'Inverted', the current and power value reported by the second meter in line 1 will be inverted in sign. | Yes | R/W | Enum | (0) Standard (1) Inverted (2) Suppress-signed Def: Standard |
CurrentDirSecondL2 | Individual | No | If set to 'Inverted', the current and power value reported by the second meter in line 2 will be inverted in sign. | Yes | R/W | Enum | (0) Standard (1) Inverted (2) Suppress-signed Def: Standard |
CurrentDirSecondL3 | Individual | No | If set to 'Inverted', the current and power value reported by the second meter in line 3 will be inverted in sign. | Yes | R/W | Enum | (0) Standard (1) Inverted (2) Suppress-signed Def: Standard |
WrittenOfferAddress | Both | No | Configures the postal address part of the written offer that the user can write to in order to request the GPL software. (Multiple lines can be separated by commas.) | No | R | String | Def: "Ebee Smart Technologies GmbH, Torgauer Str. 12-15 (Haus 4), 10829 Ber..." |
ManufacturerURL | Master | No | Configures the uniform resource locator (URL) of the manufacturer. The manufacturer URL is used by various network services such as the SEMP interface. | No | R | String | Def: "https://www.bender.de" |
AuthorizationInput | Not relevant | No | Input used for authorization from an external switch/relay. If triggered, an AuthorizeRequest with a fixed idtag 'input_auth' will be sent to the backend. To authorize successfully, 'input_auth' needs to be configured in the backend. | Yes | R | Enum | (0) Disable (1) Enable 'Opto 1 In' Def: Disable |
RestInterfaceEnable | Both | No | This option enables the REST interface. It provides the status of the charge controller, error messages and charging session information. The interface can be used to show information on a customer-facing display of the charger. The option 'Enabled (without UID)' prevents access to user authentication information. 'Enabled (with UID)' shows user authentication information and may be used, when interfaces are protected against unauthorized access. | Yes | R/W | Enum | (0) Disabled (1) Enabled (with UID) (2) Enabled (without UID) Def: Disabled |
DlmHierarchicalMode | Master | No | If selected, this node will function as the DLM Coordinator (i.e. the "central" node) of the hierarchical DLM network. There can only be a single coordinator | Yes | R/W | Enum | (0) Disabled (1) Enabled (with local MQTT broker) (2) Enabled (with remote MQTT broker) Def: Disabled |
DlmcAddress | Master | No | This unique address identifies this controller in the hierarchical DLM network. The schema has to be the equivalent to the hierarchy in the constraints for this hierarchical DLM network. | Yes | R/W | String | Def: "" |
DlmcMqttBrokerAddress | Master | No | The IP address for the broker. On one of the controllers in the hierarchical DLM network has to be run the MQTT broker. Use the IP address of the controller where the value "Enabled (with local MQTT broker)" was set. | Yes | R/W | String | Def: "" |
DlmcMqttBrokerPort | Master | No | The port on which this controller connects to the MQTT broker. The default is 8883. | Yes | R/W | uint | [1024..65535] Def: 8883 |
DlmcMaximumFallbackCurrent1 DlmcMaximumFallbackCurrent2 DlmcMaximumFallbackCurrent3 | Master | No | When the connection to the DLM coordinator is lost then this fallback current (L1/L2/L3) [A] is set for the DLM master | Yes | R/W | Triple | [0..10000] Def: 20:20:20 |
DlmcPublishConstraints | Master | No | When enabled the constraints will be published to the MQTT broker | Yes | R/W | Enum | (0) Off (1) On Def: Off |
DlmState | Individual | No | DLM State | No | R | String | Def: "Disabled" |
DlmMode | Individual | No | Specifies the ChargePoint's role in a DLM network. There MUST be exactly one DLM Master in a DLM network managing multiple DLM-Slaves. Typically, a ChargePoint configured as DLM Master will also host an internal DLM-Slave. Note: A ChargePoint configured as standalone DLM Master will not host an internal DLM-Slave. If used for charging anyway, its power consumption will be not controlled by DLM! | Yes | R/W | Enum | (0) Disabled (1) DLM Master (With internal DLM-Slave) (2) DLM Master (Standalone) (3) DLM Slave (Master-Auto-Discovery) (4) DLM Slave (Master-Fixed-IP) Def: Disabled |
DlmSolarMode_dlm | Master | No | This DLM feature allows EVs on a group of DLM clients to be charged with excess PV power. Activate solar mode on one or more participating DLM clients. The function requires a meter at the grid connection point or at the solar inverter. In 'PV surplus' mode, the EV is charged when there is enough surplus power to charge at the defined minimum current. EVs in this mode charge mostly without energy from the grid. The 'PV surplus + grid support' mode uses a defined power contribution from the grid to enable charging when PV production is insufficient. This allows the vehicle to be charged primarily with self-produced energy. | No | R/W | Enum | (0) DLM standard (1) PV surplus (3) PV surplus + grid support Def: DLM standard |
DlmDiscoveryNetworkId | Master | No | Several DLM groupings might coexist in one physical LAN. In case of DLM Master-Auto-Discovery, they are distinguished by Master-Auto-Discovery Network Id. | Yes | R/W | uint | [0..255] Def: 0 |
DlmMasterIp | Master | No | DLM Master IP which is used for DLM-Slaves configured with Master-Fixed-IP. Additionally the connection port can be specified (IP[:port]). | Yes | R/W | String | Def: "" |
DlmTimeTableScheduleRandomization | Not relevant | No | Delay the scheduled activation of a specified current limit by a random number of seconds between 0 and this. Example: assume a value of 100 is set and the time table is set to restrict the current to 6 A at 2 pm. The limit would be enforced at 14:00:00 + a random number of seconds up to 100, effectively between 14:00:00 and 14:01:39 | No | R/W | uint | [0..1800] Def: 0 |
DlmPhase1Limit DlmPhase2Limit DlmPhase3Limit | Master | No | Overall current limit for DLM available for distribution to EVs. | Yes | R/W | Triple | [0..10000] Def: 16:16:16 |
DlmOperatorPhase1Limit DlmOperatorPhase2Limit DlmOperatorPhase3Limit | Master | No | Operator current limit for DLM available for distributionto EVs. The 'Operator EVSE Sub-Distribution Limit' is equal or smaller than the 'EVSE Sub-Distribution Limit'. It can be changed without rebooting the chargepoint. Thus a backend could use this parameter to alter the energy available for charging EVs dynamically. The backend will not be able to set a value higher than the 'EVSE Sub-Distribution Limit'. | No | R/W | Triple | [0..10000] Def: 16:16:16 |
DlmExtMeterMainDistributionLimitPhase1 DlmExtMeterMainDistributionLimitPhase2 DlmExtMeterMainDistributionLimitPhase3 | Master | No | Current limit for DLM available for distribution to EVs and additional energy loads. This value is typically higher than the 'EVSE Sub-Distribution Limit' above. An external meter is required to detect the energy consumption of the additional load. | Yes | R/W | Triple | [0..10000] Def: 100💯100 |
DlmExtLoadHeadroomPhase1 DlmExtLoadHeadroomPhase2 DlmExtLoadHeadroomPhase3 | Master | No | Safety margin to avoid transient overload situations. The algorithm will keep headroom towards 'Main Distribution Limit' | No | R/W | Triple | [0..10000] Def: 0:0:0 |
DlmExtLoadAvgLen | Master | No | Meter values will be averaged in order to avoid transients. | Yes | R/W | uint | [2..3600] Def: 5 |
DlmDisconnectedLimit | Both | No | Current limit when disconnected from DLM network. | Yes | R/W | uint | [0..100] Def: 6 |
DlmMinCurrentRating | Both | No | Minimum current limit that charging should not go below. | Yes | R/W | uint | [6..100] Def: 6 |
DlmSlaveSolarEnabled | Both | No | This parameter is used to signal to the DLM master that the charging station is participating in solar charging. The DLM master then checks whether there is sufficient excess PV power in the current solar charging mode to charge the vehicles connected to the station. Participation in solar charging can be terminated during a charging process if desired (setting: “Off”). In this case, the normal DLM algorithm is applied. | No | R/W | Enum | (0) Off (1) On Def: Off |
DlmCurrImbalanceLim | Master | No | Maximum allowed phase imbalance. DLM will not exceed the 'Current Imbalance Limit' between phases when assigning current to EVs. | Yes | R/W | uint | [0..255] Def: 20 |
DlmExtMeterLoadFallbackPhase1 DlmExtMeterLoadFallbackPhase2 DlmExtMeterLoadFallbackPhase3 | Master | No | In the error case, where the external meter is disconnected or fails, 'External Load Fallback' is assumed as consumption of an additional consumer. Setting to a high value will result in no current available for the EVSE sub-distribution in that particular situation. Thus, charging would stop | Yes | R/W | Triple | [0..10000] Def: 9999:9999:9999 |
DlmInput1CurrOffsetPhase1 DlmInput1CurrOffsetPhase2 DlmInput1CurrOffsetPhase3 | Master | No | Offset added to 'EVSE Sub-Distribution Limit' case external input 1 is high. Note: currently only negative values are supported. | Yes | R/W | Triple | [-10000..0] Def: 0:0:0 |
DlmInput3CurrOffsetPhase1 DlmInput3CurrOffsetPhase2 DlmInput3CurrOffsetPhase3 | Master | No | Offset added to 'EVSE Sub-Distribution Limit' case meter digital input is high. Note: currently only negative values are supported. | Yes | R/W | Triple | [-10000..0] Def: 0:0:0 |
DlmExtMeterEnabled | Master | No | If enabled, an external, secondary meter allows to also consider the power consumption of additional load. The power available for charging EVs will be adjusted accordingly. Please make sure, 'Meter configuration (Second)' is configured, preferrably to a 3-phase, phase aware meter. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
DlmExtMeterLocation | Master | No | Specifies how the external meter is connected depending on its location. Either at the grid entry point, between an external load and the rest of the installation, or to a renewable energy source such as a solar panel. | Yes | R/W | Enum | (0) Grid (1) External Load (2) Renewable Production Def: Grid |
DlmCurrImbalancePreventionEnabled | Master | No | If enabled, DLM will not exceed the 'Current Imbalance Limit' configured. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
DlmDisableDiscoveryBroadcast | Master | No | Disables the broadcasting of DLM Discovery beacons in the DLM master. If disabled, DLM slaves will not be able to find their DLM master automatically with the help of the DLM Master-Auto-Discovery feature. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
DlmRecalcInterval | Master | No | The DLM algorithm will not calculate and re-assign current to its DLM slaves any faster than at this configured rate. As an exception, EVs getting ready to charge will be considered and assigned current immedeately. | No | R/W | Enum | (1) 1 sec (2) 2 sec (5) 5 sec (15) 15 sec (30) 30 sec (60) 1 min (600) 10 min (999) 15 min Def: 30 sec |
DlmPersistentSlavesCount | Master | No | Number of persistent DLM slaves registered in DLM slave database | No | R | uint | [0..0] Def: 0 |
DlmClearPersistentSlaves | Master | No | Select 'Clear' and 'Save' to clear the database of known DLM slaves | No | R/W | Enum | (0) - (1) Clear Def: - |
DlmInput1CurrOffsetCfg | Master | No | Adds a configurable offset to 'EVSE Sub-Distribution Limit' based on GPI External Input 1. | Yes | R/W | Enum | (0) Disable (1) Enable 'Opto 1 In' Def: Disable |
DlmInput3CurrOffsetCfg | Master | No | Adds a configurable offset to 'EVSE Sub-Distribution Limit' based on the Meter's Digital Input register. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
DlmInput1Polarity | Master | No | Changes the polarity of the input signal 1. "Active high" does not change the polarity, "Active low" inverts the signal. | Yes | R/W | Enum | (0) Active high (1) Active low Def: Active high |
ModbusSlaveTCPConfigOnOff | Both | No | Activates the charging station's Modbus TCP Server function for connecting energy management systems via Ethernet. Through this interface control information and commands are transferred between charging station and energy manager. For detailed information on the Modbus registers, see the product documentation. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
ModbusSlaveRegAddrSet | Both | No | Choose the set of register addresses that the Modbus TCP Server device will expose to its Master device | Yes | R/W | Enum | (0) Phoenix (1) TQ-DM100 (2) Open Modbus Charge Control Interface (OMCCI) Def: TQ-DM100 |
ModbusSlaveAllowStartStop | Both | No | Allows transactions to be started/stopped from a Modbus Master device via the controller's Modbus TCP Server interface. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
ModbusSlaveAllowUIDDisclose | Both | No | Allows sending the UID via the Ebee Modbus TCP Server protocol | Yes | R/W | Enum | (0) Off (1) On Def: Off |
ModbusSlaveTCPPort | Master | No | Port number on which the Modbus TCP Server waits for incoming connections on connector 1. A second server waits on 'port + 100'. Its registers are read-only. In case a second connector is supported, the configured 'port + 1' and 'port + 101' will be used for that connector. | Yes | R/W | uint | [0..65434] Def: 502 |
ModbusSlaveCommTimeout | Both | No | Timeout in seconds between messages with a Modbus TCP Master device | Yes | R/W | uint | [1..2147483647] Def: 1200 |
ModbusSlaveDevAddr | Individual | No | Device address (0 to 255) to use for the Modbus TCP Server feature | Yes | R/W | uint | [0..255] Def: 10 |
SMAInterfaceOnOff | Master | No | The charging station can be networked with the SMA Sunny Home Manager 2.0 to charge primarily or exclusively with self-generated solar energy. | No | R/W | Enum | (0) Off (1) On Def: Off |
SMAChargingMode | Master | No | This option sets the directly applicable charging mode. In surplus charging mode, the vehicle charges primarily with self-generated electricity according to the setting in Sunny Portal. In immediate charging mode, control signals from the Sunny Home Manager 2.0 are ignored and the vehicle is charged with the maximum possible current regardless of the available solar power. In Manual Configuration mode, it is also possible to specify how much energy is to be charged at least until the preset departure time. This mode also uses energy from the electricity grid if not enough self-generated electricity can be provided. The expected amount of energy can be communicated to the energy manager via the maximum demand option. In each of the modes, charging continues until the vehicle is full. | No | R/W | Enum | (0) Manual configuration (1) Immediate charging (2) Surplus charging Def: Manual configuration |
SMACommunicationTimeout | Master | No | If the charging station cannot reach the energy manager for longer than set, the connection is considered to have failed. Possible value range: 60 s to 3600 s. | No | R/W | uint | [60..3600] Def: 600 |
SMACommunicationTimeoutCurrent | Master | No | If the connection to the energy manager fails, the charging current is set to the value set here. Settings between 6 A and 80 A are permissible. | No | R/W | uint | [6..80] Def: 6 |
SMAMaxEnergyDemand | Master | No | This value sets the maximum energy demand that is reported to the Energy Manager for the charging point. This value typically represents the maximum capacity of the vehicle battery. Permissible range of values: 1 kWh to 1000 kWh. | No | R/W | uint | [1..1000] Def: 30 |
SMAMinEnergyDemand | Master | No | This value sets the minimum amount of energy that is reported to the Energy Manager for the charge point. With manual configuration, at least the set amount of energy is charged by the preset time. Permissible value range: 0 kWh to 1000 kWh. | No | R/W | uint | [0..1000] Def: 5 |
SMAChargeCompleteTime | Master | No | This value configures the time of day until the charging process should be completed. At least the minimum configured energy requirement should be charged by this time. | No | R/W | String | Def: "08:00" |
EEBUSConfigOnOff | Master | No | Compatible energy managers can control the charging station via the EEBus interface. | No | R/W | Enum | (0) Off (1) On Def: Off |
EEBUSModuleVersion | Master | No | No | R/W | uint | [0..4294967295] Def: 0 | |
EEBUSModuleShipId | Master | No | No | R/W | String | Def: "" | |
EEBUSConfigCevcOnOff | Master | No | Compatible energy managers can control the charging station via the EEBus interface. | No | R/W | Enum | (0) Off (1) On Def: Off |
EEBUSFallbackCurrent | Master | No | If the connection to the energy manager fails, the charging current is set to the value set here. Settings between 6 A and 80 A are permissible. | No | R/W | uint | [6..80] Def: 6 |
EEBUSCommunicationTimeout | Master | No | If the charging station cannot reach the energy manager for longer than set, the connection is considered to have failed. If the energy manager serves to protect the main fuse from overload, a correspondingly short time is recommended. Possible value range: 4 s to 3600 s. | No | R/W | int | [4..3600] Def: 4 |
EEBUSPairedCemId | Master | No | Identifier issued by the coupled energy manager for identification purposes. | No | R/W | String | Def: "" |
EEBUSPairedCemSki | Master | No | Subject Key Identifier of the coupled energy manager for identification purposes. | No | R/W | String | Def: "" |
EEBUSPairedCemUri | Master | No | No | R/W | String | Def: "" | |
EEBUSPairedCemModelName | Master | No | No | R/W | String | Def: "" | |
EEBUSPairedCemIp | Master | No | No | R/W | String | Def: "" | |
EEBUSEnableKeoLogging | Master | No | Enable logging of KEO stack messages | No | R/W | Enum | (0) Off (1) On Def: Off |
EEBusLPCFailsafePowerUser | Master | No | If the connection to the energy manager fails, the failsafe power for LPC is set to the value set here. | No | R/W | uint | [0..66000] Def: 11040 |
EEBusLPCFailsafePowerEnergyGuard | Individual | No | If the connection to the energy manager fails, the power is set to the value set by the energy guard. | No | R/W | uint | [0..66000] Def: 11040 |
EEBusLPCFailsafeDurationMinUser | Master | No | The minimum duration that the system will remain in the LPC failsafe state if the connection to the energy manager fails. Possible value range: 7200 s to 86400 s. | No | R/W | uint | [7200..86400] Def: 7200 |
EEBusLPCFailsafeDurationMinEnergyGuard | Individual | No | The minimum duration that the system will remain in the failsafe state if the connection to the energy manager fails. The value is set by the energy guard. Possible value range: 7200 s to 86400 s. | No | R/W | uint | [7200..86400] Def: 7200 |
HemsConfigChargingMode | Master | No | This option allows to select the charging mode used by the EEBus system."Mains charging" configures the charging with mains power. The options "Solar charging" and "Solar surplus charging" configure the usage of self-produced solar power for charging. The first two options aim at optimizing the self-consumption whereas "Solar surplus charging" additionally configures the exclusive usage of solar surplus power for charging. | No | R/W | Enum | (0) Mains charging (1) Solar charging (2) Solar surplus charging Def: Mains charging |
HemsConfigMaxEnergyDemand | Master | No | This value sets the maximum energy demand that is reported to the Energy Manager for the charging point. This value typically represents the maximum capacity of the vehicle battery. Permissible range of values: 1 kWh to 1000 kWh. | No | R/W | uint | [1..1000] Def: 30 |
HemsConfigMinEnergyDemand | Master | No | This value sets the minimum amount of energy that is reported to the Energy Manager for the charge point. With manual configuration, at least the set amount of energy is charged by the preset time. Permissible value range: 0 kWh to 1000 kWh. | No | R/W | uint | [0..1000] Def: 5 |
HemsConfigOptEnergyDemand | Master | No | This value sets the optimal amount of energy that is reported to the Energy Manager for the charge point. With manual configuration, at least the set amount of energy is charged by the preset time. Permissible value range: 0 kWh to 1000 kWh. | No | R/W | uint | [0..1000] Def: 8 |
HemsConfigChargeCompleteTime | Master | No | This value configures the time of day until the charging process should be completed. At least the minimum configured energy requirement should be charged by this time. | No | R/W | String | Def: "08:00" |
HemsDeviceName | Master | No | Allows the configuration of an HEMS-specific device name for systems such as EEBus or SEMP. Please note that this value is not adopted immediately if the system in question is already coupled with an energy manager. | Yes | R/W | String | Def: "CC613_ELM4PR_M" |
SignedUpdates | Both | No | Enables or disables the signature verification for software updates. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
BannerEnabled | Not relevant | No | A Banner SureCross DX80-PB2 gateway can be connected via the charging station's external Modbus RTU interface. Each gateway can connect up to 47 M-GAGE wireless sensors for parking space occupancy detection. The charging station connected to the gateway sends the occupancy data for all connected sensors via OCPP DataTransfer to the set backend, which may evaluate the data. Note: Modbus ID 3 must be set in the DX80 gateway configuration. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
BannerReadAnalog | Not relevant | No | For testing and analysis purposes, raw analogue data from the parking sensor can be transmitted to the backend. As more data is transmitted, the data retrieval interval need to be increased. In normal operation, the transmission of raw data is not necessary. | Yes | R/W | Enum | (0) Off (1) On Def: Off |
BannerPollInterval | Not relevant | No | Specifies the interval in seconds at which the charging station retrieves sensor data from the gateway. New data can be retrieved after 20 seconds at the earliest. When retrieving raw analogue data, the interval must be at least 40 seconds. The interval should be extended if many sensors are connected and data from connected sensors is missing. | Yes | R/W | uint | [0..4294967295] Def: 20 |
BannerSendInterval | Not relevant | No | Specifies the interval in seconds at which sensor data is sent to the OCPP backend. The send interval should be at least 40 seconds and must not be shorter than the data retrieval interval. Intervals between 60 and a maximum of 600 seconds are recommended. | Yes | R/W | uint | [0..4294967295] Def: 60 |
BannerMaxNodeId | Not relevant | No | Parking sensors are integrated in the gateway with a consecutive number. The gateway has the number 0, the first sensor the number 1. Up to 47 sensors can be read via the gateway. | Yes | R/W | uint | [0..47] Def: 0 |
GeolocationUpdate | Master | No | Request or update the geolocation data | No | W | Button |
5. OCPP Keys Mapping
Description: This section provides details for the OCPP Keys Mapping tab extracted from the documentation HTML.
Web page key name | Master/Slave Scope | Reboot Required | OCPP Keys Name | OCPP Standard | Configuration File Name |
---|---|---|---|---|---|
RCMB Delta | Both | No | RCMBDelta | No | RCMBThreshold_rcmb |
Maximum RMS value of last transaction | Individual | No | RCMBTransactionMaxRMS | No | RCMBTransactionMaxRMS_rcmb |
Maximum DC value of last transaction | Individual | No | RCMBTransactionMaxDC | No | RCMBTransactionMaxDC_rcmb |
Welded contactor detection | Individual | Yes | WeldCheck | No | WeldCheck_rcmb |
Welded contactor input type | Individual | Yes | WeldCheckInType | No | WeldCheckInType_rcmb |
Time zone | Both | Yes | No | EbeeAppTimezone_custom | |
ChargePoint Vendor | Both | Yes | ChargePointVendor | No | ChargePointVendor_branding |
ChargePoint Model | Not relevant | Yes | ChargePointModel | No | ChargePointModel_branding |
SSH Access via USB | Individual | Yes | SSHAccessUsb | No | SSHAccessUsb_custom |
SSH Access via WLAN | Individual | Yes | SSHAccessWlanNetwork | No | SSHAccessWlanNetwork_custom |
SSH Access via Ethernet | Individual | Yes | SSHAccessEth | No | SSHAccessEthernet_custom |
SSH Access via GSM | Individual | Yes | SSHAccessGsm | No | SSHAccessGsm_custom |
Filter Out Invalid RFIDs | Both | Yes | InvalidRFIDFilter | No | InvalidRFIDFilter_custom |
Enforce Password change | Both | No | EnforcePwdChange | No | EnforcePwdChange_custom |
Enforce strong login passwords | Both | No | EnforceStrongLoginPwds | No | EnforceStrongLoginPwds_custom |
RFID Mode | Both | Yes | RFIDMode | No | RFIDMode_custom |
Enforce Master RFID | Both | No | EnforceMasterRFID | No | EnforceMasterRFID_custom |
Enforce using Secure RFID | Both | No | EnforceSecureRFID | No | EnforceSecureRFID_custom |
Controller serial number | Individual | Yes | ChargeBoxSerialNumber | No | SerialNumber_custom |
Manufacturer serial number | Master | Yes | ChargePointSerialNumber | No | SerialNumberManufacturer_custom |
User Password | Both | No | No | UserPwdPlain_custom | |
Installer Password | Both | No | No | InstallerPwdPlain_custom | |
Operator Password | Both | No | No | OperatorPwdPlain_custom | |
Manufacturer Password | Not relevant | No | No | ManufacturerPwdPlain_custom | |
Factory Reset by RFID | Individual | No | MasterRFIDstoReset | No | ResetToDefaultsRFID_custom |
Reset Password PUK | Individual | No | No | ResetPasswordPUK_custom | |
State page password protection | Both | Yes | No | StatePageLock_custom | |
Authorization Input Mode | Not relevant | Yes | AuthorizationInputMode | No | AuthorizationInputMode_custom |
Authorization Input Switch Type | Not relevant | Yes | AuthorizationInputType | No | AuthorizationInputType_custom |
Log Level | Both | No | loglevel | No | LogLevel_custom |
State 'unavailable' at FW update begin | Both | No | No | UnavailAtFwUpdateBegin_custom | |
Restore time | Not relevant | Yes | No | RestoreTime_custom | |
Power source voltage | Individual | Yes | PowerLineVoltage | No | PowerSourceVoltage_custom |
High frequency react threshold (mHz) | Both | Yes | No | FrequencyMonitorReactHigh_custom | |
Current at normal grid frequency (A) | Both | Yes | No | FreqMonNormalCurrent_custom | |
Low frequency react threshold (mHz) | Both | Yes | No | FrequencyMonitorReactLow_custom | |
Current at low grid frequency (A) | Both | Yes | No | FreqMonLowCurrent_custom | |
Low frequency stop threshold (mHz) | Both | Yes | No | FrequencyMonitorStopLow_custom | |
Frequency load management randomization (s) | Both | Yes | No | FreqLoadManagamentRandomization_custom | |
Master/Slave Mode | Not relevant | Yes | MasterSlaveMode | No | MasterSlaveMode_ms |
Email notification in case of errors | Master | Yes | No | EmailEnabled_mail | |
Email provider account username | Master | Yes | No | EmailUsername_mail | |
Email provider account password | Master | Yes | No | EmailPassword_mail | |
SMTP server and port | Master | Yes | No | EmailServerPort_mail | |
SMTP connection security | Master | No | No | EmailConnSecurity_mail | |
Location of charge point in outgoing emails | Master | Yes | No | EmailCpLocation_mail | |
'From:' address in outgoing emails | Master | Yes | No | EmailFromAddress_mail | |
'To:' address(es) in outgoing emails | Master | Yes | No | EmailToAddress_mail | |
Send test email | Master | No | No | EmailTestSend_mail | |
Resend last email session report | Master | No | No | EmailSessionReportResend_mail | |
Send email session report | Both | No | No | EmailSessionReport_mail | |
Session report format | Both | No | No | EmailAttachmentType_mail | |
Manufacturer specific mail server | Master | Yes | No | ManufacturerSpecificMailServer_mail | |
LED Type | Not relevant | No | LedType | No | LedType_hmi |
Dual LED board mode | Not relevant | No | DualLedMode | No | DualLedMode_hmi |
Type of Display | Not relevant | No | DisplayType | No | DisplayType_hmi |
Mode for Display | Not relevant | No | DisplayMode | No | DisplayMode_hmi |
Display charging time | Not relevant | No | DisplayContentSelectorTime | No | DisplayContentSelectorTime_hmi |
Display energy | Not relevant | No | DisplayContentSelectorEnergy | No | DisplayContentSelectorEnergy_hmi |
Display power | Not relevant | No | DisplayContentSelectorPower | No | DisplayContentSelectorPower_hmi |
HMI Pattern On Relay 2 (K2) | Not relevant | No | PatternOnRelayK2 | No | HMIPatternOnRelayK2_V2_hmi |
Language of Display | Individual | No | DisplayLanguage | No | DisplayLanguage_hmi |
CC613 Buzzer Test | Individual | No | No | CC613BuzzerTest_hmi | |
Schuko Socket | Not relevant | Yes | OCPPSchuko | No | Schuko_vehicleif |
Actuator type | Not relevant | Yes | EOActuatorType | No | EO_ActuatorType_vehicleif |
Type 2 Contactor Lifetime | Individual | Yes | Type2ContactorLifetime | No | Type2ContactorLifetime_vehicleif |
Type 2 Plug Lifetime | Individual | Yes | Type2PlugLifetime | No | Type2PlugLifetime_vehicleif |
Type 2 Plug Cycles | Individual | No | No | Type2PlugCounter_vehicleif | |
Set type 2 plug cycles to | Individual | No | SetType2PlugCycles | No | Type2PlugCounterWeb_vehicleif |
Type 2 Plug Cycles | Not relevant | No | Type2PlugCounter | No | Type2PlugCounterRO_vehicleif |
Contactor Cycles Type2 | Individual | No | No | Type2NumberContactorCycles_vehicleif | |
Set type 2 contactor cycles to | Individual | No | SetTypeContactorCycles | No | Type2NumberContactorCyclesWeb_vehicleif |
Contactor Cycles Type2 | Individual | No | ContactorCyclesType2 | No | Type2NumberContactorCyclesRO_vehicleif |
Threshold Contactor Current Under Load [A] | Individual | Yes | ThresholdContactorCurrentUnderLoad | No | ThresholdContactorCurrentUnderLoad_vehicleif |
Contactor Cycles Under Load Limit | Individual | Yes | ContactorCyclesUnderloadLimit | No | ContactorCyclesUnderLoadLimit_vehicleif |
Contactor Cycles Under Load | Individual | No | No | ResetCountforContactorCyclesUnderloadTo_vehicleif | |
Set contactor cycles under load to | Individual | No | SetCountContactorCyclesType2UnderLoad | No | Type2NumberContactorCyclesUnderLoadWeb_vehicleif |
Number of contactor cycles under load | Individual | No | GetCountContactorCyclesType2UnderLoad | No | CountContactorCyclesType2UnderLoad_vehicleif |
ADC CP line calibration reference value | Individual | No | No | AdcCpCalibrationVal_vehicleif | |
ADC CP line calibration reference value for 5% | Individual | No | No | AdcCpCal5PerCentVal_vehicleif | |
Fixed cable attached | Not relevant | Yes | CableAttached | No | CableAttached_vehicleif |
Detect Control Pilot Diode | Individual | No | CPDiodeDetection | No | DetectCPDiode_vehicleif |
Pause/prevent charging in state D | Both | No | PauseChargingStateD | No | PauseChargingStateD_vehicleif |
ADC calibration for CP line | Individual | Yes | AdcCpCalibrationCfg | No | AdcCpCalibrationCfg_vehicleif |
Stop limit in (%) for 'Check for car overload' | Both | Yes | CheckCarOverCurrentStopLimit | No | CheckCarOverCurrentStopLimit_vehicleif |
Maximum Current [A] | Individual | Yes | HardwareCurrentLimit | No | HardwareCurrentLimit_vehicleif |
Installation Current Limit [A] | Individual | Yes | InstallationCurrentLimit | No | InstallationCurrentLimit_vehicleif |
Operator Current Limit [A] | Individual | No | OperatorCurrentLimit | No | OperatorCurrentLimit_vehicleif |
Free Charging | Both | No | FreeCharging | No | FreeCharging_vehicleif |
Check for car overload | Both | No | CheckCarOverCurrent | No | CheckCarOverLoad_vehicleif |
Randomize charging after power loss | Both | Yes | RandomRestartAfterPowerLoss | No | RandomRestartAfterPowerLoss_vehicleif |
Type of phase switching relay (NO/NC) | Individual | Yes | No | PhaseSwitchingContactorType_vehicleif | |
Use phase switching relay (1ph <> 3ph) | Individual | Yes | No | PhaseSwitchingOutput_vehicleif | |
PDL Power | Master | No | PDL_Power | No | PDLPower_vehicleif |
Delay status update | Both | No | No | DelayStatusUpdateStartTrans_vehicleif | |
Phases connected to the ChargePoint | Individual | Yes | No | PhasesNumber_custom | |
Energy management from external input | Individual | Yes | EnergyManInputPowerLimitCfg | No | InputPowerLimit_energyman |
Phase rotation of the ChargePoint | Individual | Yes | No | PhaseRotationInternal_energyman | |
Phase rotation of the single phase IT ChargePoint | Individual | Yes | No | PhaseRotationITInternal_energyman | |
Current limit for energy management from external input | Individual | Yes | EnergyManInputPowerCurrentLim | No | InputCurrentLimit_energyman |
HawkBit client | Not relevant | Yes | No | HawkBitEnableConfiguration_hawkbit | |
HawkBit server base URL | Not relevant | Yes | No | HawkBitBaseUrl_hawkbit | |
HawkBit client controller ID | Not relevant | Yes | No | HawkBitControllerId_hawkbit | |
HawkBit client tenant ID | Not relevant | Yes | No | HawkBitTenantId_hawkbit | |
HawkBit client authorization token | Not relevant | Yes | No | HawkBitAuthToken_hawkbit | |
HawkBit client force HTTPS | Not relevant | No | No | HawkBitForceHttps_hawkbit | |
RCD Auto Reclosure | Both | Yes | RCDAUTORECLOSURE | No | RcdAutoReclosure_mon |
RCD Enable | Both | Yes | RCDENABLE | No | RcdEnable_mon |
SPD Config | Individual | Yes | SPDCFG | No | SPDConfig_mon |
Fan or heater control configuration | Both | Yes | VentHeatingCtrlMode | No | VentHeatingTempCtrlMode_mon |
Weld check output | Both | No | WeldCheckAuxRelay | No | WeldCheckAuxRelay_mon |
RCD auto reclosure delay | Both | Yes | RCDAUTORECLOSUREDELAY | No | RcdAutoReclosureDelay_mon |
RCD auto reclosure attempts | Both | Yes | RCDAUTORECLOSUREATTEMPTS | No | RcdAutoReclosureAttempts_mon |
Fan or heater control hysteresis configuration | Both | Yes | VentHeatingHyst | No | VentHeatingHyst_mon |
Temperature threshold for fan or heater control | Both | Yes | VentHeatingTempThr | No | VentHeatingTempThr_mon |
Charging Station temperature delta | Individual | No | AmbientCpuDelta | No | TempControlAmbientCpuDelta_mon |
Local time for housekeeping reboot | Both | Yes | LocalScheduledReboots | No | LocalTimeToReboot_mon |
Number of days for housekeeping reboot | Both | No | DaysScheduledReboots | No | DaysToReboot_mon |
Charging current to reduce temperature [A] | Individual | No | ReducedCurrent | No | TempControlReducedCurrent_custom |
Charging current (in % of signaled current) to reduce temperature | Individual | No | ReducedCurrentPct | No | TempControlReducedPercentage_custom |
Temperature Report Delta | Master | No | TempDelta | No | TempDelta_mon |
Temperature threshold 2 | Individual | No | TempStopThreshold2 | No | TempControlStopThr_mon |
Temperature threshold 1 | Individual | No | TempReduceThreshold1 | No | TempControlReduceThr_mon |
WLAN connection status | Master | No | No | WlanConnectionStatus_mon | |
Backend controlled mode for inputs and outputs | Both | Yes | InputOutputBackendControlledMode | No | InOutputBackendControlled_iom |
Backend notification for input changes | Both | No | InputChangeNotifyBackend | No | InputChangeNotifyBackend_iom |
Tamper detection sensor enable | Individual | Yes | TamperDetectionInputEnable | No | TamperDetectionInputEnable_tam |
DataTransfer for Tariff And Total Usage | Both | No | DataTransferTariffUsage | No | TariffAndUsageDataTransfer_ocpp |
Ignore OCPP ParentID | Both | Yes | No | IgnoreParentId_ocpp | |
Send Authorize for RemoteStart | Both | Yes | AuthorizeRemoteTxRequests | Yes | AuthorizeRemoteStarts_ocpp |
If in doubt allow charging | Both | No | AllowOfflineTxForUnknownId | Yes | IfInDoubtAllowCharging_ocpp |
Send informative StatusNotifications | Both | No | InfoStatusNotifications | No | InfoStatusNotifications_ocpp |
Send error StatusNotifications | Both | Yes | ErrorStatusNotifications | No | ErrorStatusNotifications_ocpp |
Send USB error StatusNotifications | Individual | Yes | UsbErrorStatusNotifications | No | UsbErrorStatusNotifications_ocpp |
Strategy for StatusNotification state transitions | Both | Yes | StatusNotificationStrategy | No | StatusNotificationStrategy_ocpp |
Display backend disconnect as error | Master | Yes | DisplayDisconnectAsError | No | DisconnectAsError_ocpp |
Enable OCPP whitelist | Master | No | AuthorizationCacheEnabled | Yes | UseCache_ocpp |
RFID Tag letter case | Both | Yes | idTagLetterCase | No | OCPPIDTagLetterCase_ocpp |
Stop Transaction On EV Side Disconnect | Both | No | StopTransactionOnEVSideDisconnect | Yes | StopTransactionOnEVSideDisconnect_ocpp |
Unlock Connector On EV Side Disconnect | Both | No | UnlockConnectorOnEVSideDisconnect | Yes | UnlockConnectorOnEVSideDisconnect_ocpp |
Free Charging Mode | Both | Yes | FreeChargingMode | No | FreeChargingMode_ocpp |
Allow long get configuration keys | Both | Yes | AllowLongOcppGetConfKeys | No | AllowLongOcppGetConfKeys_ocpp |
Integer values for boolean get configuration keys | Both | No | OcppGetConfBoolIsInt | No | OcppGetConfBoolIsInt_ocpp |
Stop Transaction on invalid ID | Individual | No | StopTransactionOnInvalidId | Yes | StopTransactionOnInvalidId_ocpp |
OCPP ChargeBoxIdentity (ChargePointID) | Individual | Yes | ChargeBoxIdentity | No | ChargePointID_ocpp |
RFID Tag for Free Charging with OCPP Full, fixed RFID modes | Individual | Yes | RfidTagFreeCharging | No | RfidTagFreeCharging_ocpp |
Backend connection timeout | Master | Yes | BackendConnectionTimeout | No | ConnectionTimeOut_ocpp |
Vehicle connection timeout [s] | Both | Yes | ConnectionTimeOut | Yes | VehicleConnectionTimeout_ocpp |
Number of transaction message attempts | Individual | Yes | TransactionMessageAttempts | Yes | TransactionMessageAttempts_ocpp |
Number of Eichrecht transaction message attempts | Individual | Yes | EichrechtTransactionMessageAttempts | No | EichrechtTransactionMessageAttempts_ocpp |
Transaction message retry interval (seconds) | Individual | Yes | TransactionMessageRetryInterval | Yes | TransactionMessageRetryInterval_ocpp |
Number of reset retries | Individual | Yes | ResetRetries | Yes | ResetRetries_ocpp |
Disallow charging if OCPP queue full | Both | Yes | OcppQueueFullAsErrorState | No | OcppQueueFullAsErrorState_ocpp |
Local Pre Authorize | Master | No | LocalPreAuthorize | Yes | LocalPreAuthorize_ocpp |
Local Authorize Offline | Master | No | LocalAuthorizeOffline | Yes | LocalAuthorizeOffline_ocpp |
Force OCPP connector state to available/unavailable | Both | No | No | ForceStateAvail_ocpp | |
Force Heartbeat request messages | Not relevant | Yes | ForceHeartbeatRequestMessages | No | ForceHeartBeat_ocpp |
Retransmit MeterValues | Both | No | RetransmitMeterValues | No | RetransmitMeterValues_ocpp |
ChargePoint UPnP UUID | Individual | Yes | UPnPUUID | No | ChargePointUUID_ocpp |
Heartbeat interval (OCPP 1.6) | Master | No | HeartbeatInterval | Yes | HeartBeatInterval_ocpp |
Stop Transaction Mode | Both | Yes | StopTransactionModeUnplug | No | StopTransactionMode_ocpp |
Hmi led light intensity control | Both | No | LightIntensity | Yes | LightIntensity_ocpp |
Send status notification to the backend for webui login event | Both | No | StatusNotificationWebuiLogin | No | StatusNotificationWebuiLogin_ocpp |
USB Field Engineer | Both | Yes | USBFieldEngineer | No | UsbFieldEngineer_usbhotplug |
USB Config update | Both | Yes | USBConfigUpdate | No | UsbConfigUpdate_usbhotplug |
USB Firmware update | Both | Yes | USBFirmwareUpdate | No | UsbFirmwareUpdate_usbhotplug |
USB script execution | Not relevant | Yes | No | UsbScriptExec_usbhotplug | |
USB Installer Password | Not relevant | No | No | UsbInstallerPasswordPlain_usbhotplug | |
Average energy per session | Individual | No | No | AveragekWh_sql | |
Average duration per session | Individual | No | No | AverageTransactionDurationStr_sql | |
Average duration per session | Individual | No | No | AverageTransactionDuration_sql | |
Average duration per session | Individual | No | No | AverageTransactionDurationSeconds_sql | |
Total Charging Sessions | Individual | No | No | TransactionsInDatabase_sql | |
This month's transaction count | Individual | No | No | TransactionsThisMonth_sql | |
This month's kWh consumption | Individual | No | No | TotalkWhThisMonth_sql | |
OCPP whitelist learning mode | Master | No | No | CacheFillMode_cache | |
OCPP whitelist expiry mode | Master | Yes | No | CacheExpiryOption_cache | |
Enable OCPP whitelist | Master | No | LocalAuthListEnabled | Yes | LocalAuthListEnabled_cache |
OCPP whitelist version number | Master | No | No | CacheVersion_cache | |
Local whitelist learning mode | Master | No | No | FLLFillMode_fll | |
Enable local whitelist | Master | No | fll | No | FllCfg_fll |
Send OCPP Start/Stop transaction | Both | No | fllUseOcppStartStop | No | FLLUseOcppStartStop_fll |
Connection Type | Master | Yes | ConnectionType | No | Type_dl |
Static USB network configuration additional IP | Not relevant | No | No | USBAdditionalIP_dl | |
Static USB network configuration gateway | Not relevant | No | No | USBAdditionalGW_dl | |
Static USB network configuration DNS | Individual | No | No | USBAdditionalDNS_dl | |
Data Consumption | Master | No | DataConsumption | No | DataConsumption_dl |
Data Consumption Last Month | Master | No | DataConsumptionLastMonth | No | DataConsumptionLastMonth_dl |
Access Point Name (APN) | Master | Yes | APN | No | APN_modem |
Network selection mode | Master | Yes | ModemNetworkSelMode | No | NetworkOperSelMode_modem |
Modem Access Technology | Master | Yes | ModemNetworkType | No | NetworkType_modem |
Network operator name format | Master | Yes | ModemNetworkOperFmt | No | NetworkOperNameFormat_modem |
Scan network operators at boot | Master | Yes | ScanNetworkOperators | No | ScanNetworkOps_modem |
APN Username | Master | Yes | APNUsername | No | APNUsername_modem |
APN Password | Master | Yes | APNPassword | No | APNPassword_modem |
Requested Network operator | Master | Yes | Req3GNetworkOperator | No | ReqNetworkOperator_modem |
Received Signal Strength Indicator (RSSI) | Master | No | RSSI | No | RSSI_modem |
Mode for ethernet configuration | Master | Yes | NetworkConfigMode | No | NetworkConfig_mode_tcpip |
Static network configuration IP | Master | Yes | StaticNetworkConfigAddress | No | NetworkConfigStaticAddress_tcpip |
Static network configuration netmask | Master | Yes | StaticNetworkConfigNetmask | No | NetworkConfigStaticNetmask_tcpip |
Static network configuration DNS | Master | Yes | StaticNetworkConfigDNS | No | NetworkConfigStaticDNS_tcpip |
SSL Strictness as client | Master | Yes | SSLModeClient | No | SSLAuthMode_tcpip |
WAN router interface | Master | Yes | WANRouterInterface | No | WANRouterInterface_tcpip |
WAN router | Master | Yes | WANRouter | No | WANRouter_tcpip |
OCPP Mode | Master | Yes | OCPPMode | No | TCP_IP_MODE_V2_tcpip |
Connection settings fallback | Individual | Yes | ConnSettingsFallback | No | ConnectionSettingsFallback_tcpip |
Hostname (Binary OCPP) | Master | Yes | HostnameBinaryOCPP | No | BinaryOCPPHostname_tcpip |
WebSockets JSON OCPP URL of the Backend | Master | Yes | OCPPBackendJSONURL | No | JsonOCPPBackendURL_tcpip |
Websockets proxy | Master | Yes | WebsocketsProxyURL | No | WebsocketsProxyURL_tcpip |
HTTP Basic Authentication password | Master | Yes | HTTPBasicAuthPassword | No | HTTPBasicAuthPassword_tcpip |
Certificate (OCPP) | Master | No | OcppCertificate | No | OcppCertificate_tcpip |
Certificate signing request (OCPP) | Master | No | OcppCSR | No | OcppCertificateSigningRequest_tcpip |
User CA Certificate (OCPP) | Master | No | OcppUserCaCertificate | No | OcppUserCaCertificate_tcpip |
Connection Type (Backend) | Master | No | No | BackendConnectionType_tcpip | |
Client hostname | Master | Yes | NetworkConfigHostname | No | NetworkConfigHostname_tcpip |
Static network configuration gateway | Master | Yes | StaticNetworkConfigGateway | No | NetworkConfigStaticGateway_tcpip |
Port number (Binary OCPP) | Master | Yes | PortBinaryOCPP | No | BinaryOCPPPort_tcpip |
TCP Watchdog Timeout | Individual | Yes | TcpWatchdogTimeout | No | TcpWatchdogTimeout_tcpip |
DHCP client request retries | Master | Yes | NetworkConfigDHCPRetries | No | NetworkConfigDHCPRetries_tcpip |
DHCP client request timeout | Master | Yes | NetworkConfigDHCPTimeout | No | NetworkConfigDHCPTimeout_tcpip |
DHCP client request delay | Master | Yes | NetworkConfigDHCPDelay | No | NetworkConfigDHCPDelay_tcpip |
WebSockets keep-alive interval | Master | No | WebSocketPingInterval | Yes | WebSocketsKeepAliveInterval_tcpip |
OCPP connection strictness | Master | Yes | OcppConStrictTls | No | OCPPConStrictTls_tcpip |
WLAN SSID | Master | No | WLANSSID | No | WLANSSID_wlan |
WLAN password | Master | No | WLANPassword | No | WLANPassword_wlan |
Static network configuration IP | Master | Yes | WLANStaticNetworkConfigAddress | No | NetworkConfigStaticAddress_wlan |
Static network configuration netmask | Master | Yes | WLANStaticNetworkConfigNetmask | No | NetworkConfigStaticNetmask_wlan |
Static network configuration gateway | Master | Yes | WLANStaticNetworkConfigGateway | No | NetworkConfigStaticGateway_wlan |
Static network configuration DNS | Master | Yes | WLANStaticNetworkConfigDNS | No | NetworkConfigStaticDNS_wlan |
WLAN enabled | Master | No | WLANEnabled | No | Enabled_wlan |
Mode for WLAN configuration | Master | Yes | WLANNetworkConfigMode | No | NetworkConfig_mode_wlan |
DHCP client request retries | Master | No | WLANNetworkConfigDHCPRetries | No | NetworkConfigDHCPRetries_wlan |
DHCP client request timeout | Master | No | WLANNetworkConfigDHCPTimeout | No | NetworkConfigDHCPTimeout_wlan |
DHCP client request delay | Master | No | WLANNetworkConfigDHCPDelay | No | NetworkConfigDHCPDelay_wlan |
Tcpdump Interface | Individual | No | TcpdumpInterface | No | TcpdumpInterface_diag |
Start and stop 'tcpdump' run | Individual | No | Tcpdump | No | Tcpdump_diag |
15118 Configuration | Both | Yes | Config15118 | No | HlcConfig_15118 |
SECC Certificate Expiry Date (15118 protocol) | Individual | No | SeccCertExpireDate15118 | No | SeccCertExpireDate_15118 |
Extra logging | Both | Yes | Log15118 | No | HlcLogging_15118 |
EVCCID or EV's MAC address prefix for OCPP authorization | Both | Yes | MACEVCCIDPrefix | No | MACEVCCIDPrefix_15118 |
EV's MAC address | Individual | No | EVMACAddr | No | EVMACAddr_15118 |
Autocharge fixed ID | Both | Yes | autochargeid | No | AutochargeFixedID_15118 |
Autocharge | Both | Yes | Autocharge | No | AutochargeConfig_15118 |
Retrieve OCSP certificate status | Both | Yes | No | CheckOCSPCertStatus_15118 | |
15118 connection strictness | Master | Yes | P15118ConStrictTls | No | P15118ConStrictTls_15118 |
15118 EV detection timeout [s] | Both | Yes | P15118EVSlacReqTimeout | No | P15118EVSlacReqTimeout_15118 |
Configuration | Individual | Yes | OCPPMeterType | No | Config_meter |
Meter configuration (Second) | Master | Yes | SecondMeterType | No | ConfigSecond_meter |
Baud Rate for Modbus/RTU | Individual | Yes | No | MeterModbusRTUBaud_meter | |
Baud Rate for Modbus/RTU (second bus) | Individual | Yes | No | MeterModbusRTUBaudSecond_meter | |
Parity for Modbus/RTU | Individual | Yes | No | MeterModbusRTUParity_meter | |
Parity for Modbus/RTU (second bus) | Individual | Yes | No | MeterModbusRTUParitySecond_meter | |
Stop bits for Modbus/RTU | Individual | Yes | No | MeterModbusRTUStop_meter | |
Stop bits for Modbus/RTU (second bus) | Individual | Yes | No | MeterModbusRTUStopSecond_meter | |
Modbus timeout [s] for Modbus/RTU | Individual | No | No | MeterModbusTimeout_meter | |
Modbus polling frequency [ms] | Individual | No | No | MeterModbusPollingFrequency_meter | |
Modbus address of OCPP meter | Individual | Yes | No | OcppMeterModbusAddr_meter | |
Modbus address of second meter | Individual | Yes | No | SecondMeterModbusAddr_meter | |
OCPP Via Local Network minimum value '1' | Both | No | OCPPViaLocalNetwork | No | OCPPViaLocalNetwork_meter |
Meter Value Sample Interval (OCPP) | Both | No | MeterValueSampleInterval | Yes | MeterValueSampleInterval_meter |
Meter Value Sample Mode (OCPP) | Both | No | MeterValueSampleMode | No | MeterValueSampleMode_meter |
Clock aligned data interval (OCPP) | Both | Yes | ClockAlignedDataInterval | Yes | ClockAlignedDataInterval_meter |
Clock aligned random sent delay in seconds (OCPP) | Both | Yes | ClockAlignedMeterRandomSendDelay | No | ClockAlignedMeterRandomSendDelay_meter |
Meter values aligned data (OCPP) | Both | No | MeterValuesAlignedData | Yes | MeterValuesAlignedData_meter |
Meter values sampled data (OCPP) | Both | No | MeterValuesSampledData | Yes | MeterValuesSampledData_meter |
Stop transaction sampled data (OCPP) | Both | No | StopTxnSampledData | Yes | StopTxnSampledData_meter |
Stop transaction aligned data (OCPP) | Both | No | StopTxnAlignedData | Yes | StopTxnAlignedData_meter |
IP address of OCPP meter | Individual | Yes | No | OcppMeterIPAddress_meter | |
IP address of second meter | Master | Yes | SecondMeterIPAddress | No | SecondMeterIPAddress_meter |
Port number of second meter | Master | Yes | SecondMeterTCPPortNumber | No | SecondMeterTCPPortNumber_meter |
Pulses per kWh (S0 meter) | Not relevant | No | No | S0MeterPulsesPerKWh_meter | |
Pulses per kWh (Second S0 meter) | Not relevant | No | No | S0MeterPulsesPerKWhSecond_meter | |
Restart transaction after power loss | Both | Yes | RestartTransAfterPowerLoss | No | RestartAfterPowerLoss_meter |
Current flow direction of L1 of second meter | Individual | Yes | CurrentDirSecondL1 | No | CurrentDirSecondL1_meter |
Current flow direction of L2 of second meter | Individual | Yes | CurrentDirSecondL2 | No | CurrentDirSecondL2_meter |
Current flow direction of L3 of second meter | Individual | Yes | CurrentDirSecondL3 | No | CurrentDirSecondL3_meter |
Line loss switch | Individual | No | No | MeterLineLossSwitch_meter | |
Line loss percentage | Individual | No | No | LineLossPercentage_meter | |
Charging cable name | Individual | No | No | ChargingCableName_meter | |
Charging cable contact resistance (mOhm) | Individual | No | No | CableContactResistance_meter | |
Lock charging cable contact resistance | Individual | No | No | LockContactResistance_meter | |
Charging cable resistance (mOhm) | Individual | Yes | No | ChargingCableResistance_meter | |
Cable loss energy configuration | Individual | Yes | No | CableLossEnergyConfig_meter | |
Line loss resistance (Ohm) | Individual | No | No | LineLossResistance_meter | |
Mode selection | Individual | No | No | EREastronModeSelect_meter | |
Enable HTTPS | Both | Yes | No | EnableHTTPS_encryption | |
Authorization Input | Not relevant | Yes | AuthorizationInput | No | AUTHORIZATION_INPUT_custom |
Custom web configuration title | Not relevant | Yes | No | WebUICustomTitle_web | |
Append manufacturer serial to configuration title | Not relevant | Yes | No | WebUITitleSerial_web | |
Hierarchical Dynamic Load Management - DLM Coordinator | Master | Yes | DlmHierarchicalMode | No | DlmCMode_dlmc |
DLM master fallback current | Master | Yes | DlmcMaximumFallbackCurrent1 DlmcMaximumFallbackCurrent2 DlmcMaximumFallbackCurrent3 | No | DlmcMaximumFallbackCurrent_dlmc |
Publish constraints for DLM coordinator | Master | Yes | DlmcPublishConstraints | No | DlmcPublishConstraints_dlmc |
Dynamic Load Management - DLM Master/Slave | Individual | Yes | DlmMode | No | DlmMode_dlm |
Configure solar charging mode | Master | No | DlmSolarMode_dlm | No | DlmSolarMode_dlm |
DLM Network Id | Master | Yes | DlmDiscoveryNetworkId | No | DlmDiscoveryNetworkId_dlm |
DLM Master IP and port | Master | Yes | DlmMasterIp | No | DlmMasterIp_dlm |
EVSE Sub-Distribution Limit (L1/L2/L3) [A] | Master | Yes | DlmPhase1Limit DlmPhase2Limit DlmPhase3Limit | No | DlmPhaseLimit_dlm |
Operator EVSE Sub-Distribution Limit (L1/L2/L3) [A] | Master | No | DlmOperatorPhase1Limit DlmOperatorPhase2Limit DlmOperatorPhase3Limit | No | DlmOperatorLimit_dlm |
Main Distribution Limit (L1/L2/L3) [A] | Master | Yes | DlmExtMeterMainDistributionLimitPhase1 DlmExtMeterMainDistributionLimitPhase2 DlmExtMeterMainDistributionLimitPhase3 | No | DlmExternalMeterMainDistLimit_dlm |
External Load Headroom (L1/L2/L3) [A] | Master | No | DlmExtLoadHeadroomPhase1 DlmExtLoadHeadroomPhase2 DlmExtLoadHeadroomPhase3 | No | DlmExternalLoadHeadroom_dlm |
External Load Averaging Length [s] | Master | Yes | DlmExtLoadAvgLen | No | DlmExternalLoadAvgLen_dlm |
Disconnected Limit [A] | Both | Yes | DlmDisconnectedLimit | No | DlmDisconnectedLimit_dlm |
Minimum Current Limit [A] | Both | Yes | DlmMinCurrentRating | No | DlmMinCurrentRating_dlm |
Use solar mode on this charger | Both | No | DlmSlaveSolarEnabled | No | DlmSlaveEnableSolar_dlm |
Solar Mode on this charger | Not relevant | No | No | DlmHemsChargingMode_dlm | |
Current Imbalance Limit [A] | Master | Yes | DlmCurrImbalanceLim | No | DlmCurrImbalanceLimit_dlm |
External Load Fallback (L1/L2/L3) [A] | Master | Yes | DlmExtMeterLoadFallbackPhase1 DlmExtMeterLoadFallbackPhase2 DlmExtMeterLoadFallbackPhase3 | No | DlmExternalLoadFallback_dlm |
Ext. Input 1 Current Offset (L1/L2/L3) [A] | Master | Yes | DlmInput1CurrOffsetPhase1 DlmInput1CurrOffsetPhase2 DlmInput1CurrOffsetPhase3 | No | DlmInput1OffsetPhase_dlm |
Meter Digital Input Current Offset (L1/L2/L3) [A] | Master | Yes | DlmInput3CurrOffsetPhase1 DlmInput3CurrOffsetPhase2 DlmInput3CurrOffsetPhase3 | No | DlmInput3OffsetPhase_dlm |
Charging Log | Master | Yes | No | DlmChargingLog_dlm | |
External Meter Log | Master | Yes | No | DlmExternalMeterLog_dlm | |
DLM Log | Master | No | No | DlmDlmLog_dlm | |
External Meter Support | Master | Yes | DlmExtMeterEnabled | No | DlmExternalMeterEnabled_dlm |
External Meter Location | Master | Yes | DlmExtMeterLocation | No | DlmExternalMeterLocation_dlm |
Current Imbalance Prevention | Master | Yes | DlmCurrImbalancePreventionEnabled | No | DlmCurrImbalanceLimitEnabled_dlm |
Disable Discovery Broadcasting | Master | Yes | DlmDisableDiscoveryBroadcast | No | DlmDiscoveryDisableBroadcast_dlm |
Maximum Current Scheduler | Master | Yes | No | DlmTimeTableEnabled_dlm | |
DLM Algorithm Sample Rate | Master | No | DlmRecalcInterval | No | DlmAlgoSampleRate_dlm |
IT Network | Master | Yes | No | DlmITNetworkEnabled_dlm | |
Persistent DLM slave count | Master | No | DlmPersistentSlavesCount | No | DlmPersistentSlavesCount_dlm |
Clear persistent DLM slave DB | Master | No | DlmClearPersistentSlaves | No | DlmClearPersistentSlaves_dlm |
External Input 1 Config | Master | Yes | DlmInput1CurrOffsetCfg | No | DlmInput1CurrOffsetConfig_dlm |
Meter Digital Input Config | Master | Yes | DlmInput3CurrOffsetCfg | No | DlmInput3CurrOffsetConfig_dlm |
External Input 1 Polarity | Master | Yes | DlmInput1Polarity | No | DlmInput1Polarity_dlm |
Maximum grid support current [A] | Master | No | No | DlmSolarMaximumGridSupplyCurrent_dlm | |
PV surplus monitoring time to resume charging [s] | Master | No | No | DlmSolarEvseSuspendedHoldTime_dlm | |
Solar DLM external meter power offset | Master | No | No | DlmSolarExternalMeterOffset_dlm | |
Show "DLM override" button in dashboard | Not relevant | Yes | No | DlmShowOverrideButtonOnDashboard_dlm | |
Hold time after 1ph<>3ph state switching [s] | Master | No | No | DlmPhaseSwitchingHoldTime_dlm | |
Solar mode pause | Master | No | No | DlmSolarModePausingEnable_dlm | |
Start time of the solar mode pause | Master | No | No | DlmSolarModePausingStartTime_dlm | |
End time of the solar mode pause | Master | No | No | DlmSolarModePausingEndTime_dlm | |
Modbus TCP Server for energy management systems | Both | Yes | ModbusSlaveTCPConfigOnOff | No | TCPConfigOnOff_modbus_slave |
Modbus TCP Server Register Address Set | Both | Yes | ModbusSlaveRegAddrSet | No | RegAddrSet_modbus_slave |
Modbus TCP Server Allow Start/Stop Transaction | Both | Yes | ModbusSlaveAllowStartStop | No | AllowStartStop_modbus_slave |
Modbus TCP Server Allow UID Disclose | Both | Yes | ModbusSlaveAllowUIDDisclose | No | AllowUIDDisclose_modbus_slave |
Modbus TCP Server Base Port | Master | Yes | ModbusSlaveTCPPort | No | TCPPortNumber_modbus_slave |
Modbus TCP Server Communication Timeout | Both | Yes | ModbusSlaveCommTimeout | No | CommTimeout_modbus_slave |
Modbus TCP Server Device Address | Individual | Yes | ModbusSlaveDevAddr | No | SlaveDeviceAddress_modbus_slave |
SEMP interface | Master | No | SMAInterfaceOnOff | No | SempGatewayConfigOnOff_semp_gateway |
Charging Mode | Master | No | SMAChargingMode | No | SempGatewayChargingMode_semp_gateway |
Time to connection failure [s] | Master | No | SMACommunicationTimeout | No | SempGatewayCommunicationTimeout_semp_gateway |
Current in case of connection failure [A] | Master | No | SMACommunicationTimeoutCurrent | No | SempGatewayFallbackCurrent_semp_gateway |
Maximum energy demand [kWh] | Master | No | SMAMaxEnergyDemand | No | SempGatewayMaxEnergyDemand_semp_gateway |
Minimum energy demand [kWh] | Master | No | SMAMinEnergyDemand | No | SempGatewayMinEnergyDemand_semp_gateway |
Scheduled departure time [hh:mm] | Master | No | SMAChargeCompleteTime | No | SempGatewayMaxChargingTime_semp_gateway |
EEBus interface | Master | No | EEBUSConfigOnOff | No | EEBUSConfigOnOff_eebus |
Coordinated Charging Mode | Master | No | EEBUSConfigCevcOnOff | No | EEBUSConfigCevcOnOff_eebus |
Current in case of connection failure [A] | Master | No | EEBUSFallbackCurrent | No | EEBUSFallbackCurrent_eebus |
Communication Timeout [s] | Master | No | EEBUSCommunicationTimeout | No | EEBUSCommunicationTimeout_eebus |
Connect or disconnect the energy manager | Master | No | No | EEBUSCoupledEnergyManager_eebus | |
Connect or disconnect the energy manager (used for REST API) | Master | No | No | EEBUSPairingActionSelector_eebus | |
Connect or disconnect the energy manager | Master | No | No | EEBUSPairingActionSelectorLegacy_eebus | |
Identifier of the coupled energy manager | Master | No | EEBUSPairedCemId | No | EEBUSPairedCemIdentification_eebus |
SKI of the coupled energy manager | Master | No | EEBUSPairedCemSki | No | EEBUSPairedCemSki_eebus |
Coupling status of the energy manager | Master | No | No | EEBUSPairingStatus_eebus | |
Charging Summary | Master | No | No | EEBUSChargingSummary_eebus | |
EEBus stack version | Master | No | No | EEBusStackVersion_eebus | |
Failsafe power in case of connection failure [W] | Master | No | EEBusLPCFailsafePowerUser | No | EEBusLPCFailsafePowerUser_eebus |
Energy guard failsafe power in case of connection failure [W] | Individual | No | EEBusLPCFailsafePowerEnergyGuard | No | EEBusLPCFailsafePowerEnergyGuard_eebus |
Minimum duration for failsafe state [s] | Master | No | EEBusLPCFailsafeDurationMinUser | No | EEBusLPCFailsafeDurationMinUser_eebus |
Energy guard minimum duration for LPC failsafe state [s] | Individual | No | EEBusLPCFailsafeDurationMinEnergyGuard | No | EEBusLPCFailsafeDurationMinEnergyGuard_eebus |
Fail-safe current | Individual | Yes | No | FailSafeCurrent_hems | |
HEMS Current Limit | Individual | Yes | No | CurrentLimit_hems | |
Charging Mode | Master | No | HemsConfigChargingMode | No | ChargingMode_hems |
Maximum energy demand [kWh] | Master | No | HemsConfigMaxEnergyDemand | No | MaxEnergyDemand_hems |
Minimum energy demand [kWh] | Master | No | HemsConfigMinEnergyDemand | No | MinEnergyDemand_hems |
Optimal energy demand [kWh] | Master | No | HemsConfigOptEnergyDemand | No | OptEnergyDemand_hems |
Scheduled departure time [hh:mm] | Master | No | HemsConfigChargeCompleteTime | No | MaxChargingTime_hems |
HEMS device name | Master | Yes | HemsDeviceName | No | DeviceName_hems |
Send parking space occupancy data to backend | Not relevant | Yes | BannerEnabled | No | BannerEnabled_banner |
Transmit additional analogue sensor values | Not relevant | Yes | BannerReadAnalog | No | BannerReadAnalog_banner |
Interval to retrieve data from the gateway (s) | Not relevant | Yes | BannerPollInterval | No | BannerPollInterval_banner |
Interval for sending data via OCPP (s) | Not relevant | Yes | BannerSendInterval | No | BannerSendInterval_banner |
Number of connected parking sensors | Not relevant | Yes | BannerMaxNodeId | No | BannerMaxNodeId_banner |
Update geolocation data | Master | No | GeolocationUpdate | No | UpdateGeolocationButton_custom |
Delete all Smart Charging profiles | Master | Yes | Not Available | No | DeleteAllSmChrgProfilesButton_custom |
EEBUSStartPairingButton | Master | No | Not Available | No | EEBUSStartPairingButton_eebus |
EEBUSClearPairingButton | Master | No | Not Available | No | EEBUSClearPairingButton_eebus |
Start | Individual | No | Not Available | No | StartChargeViaWebInterface_webcharging |
Stop | Individual | No | Not Available | No | StopChargeViaWebInterface_webcharging |
Start (Connector 2) | Individual | No | Not Available | No | StartChargeViaWebInterface_webcharging_2 |
Stop (Connector 2) | Individual | No | Not Available | No | StopChargeViaWebInterface_webcharging_2 |
6. OCPP REST
Description: This section provides details for the OCPP REST tab extracted from the documentation HTML.
Key name | Key values or example |
---|---|
conn_state | no_vehicle_connected vehicle_connected_schuko vehicle_charging_schuko vehicle_connected_type2 vehicle_charging_type2 vehicle_connector_error |
auth_state | not_authorized_for_charging wait_for_auth authorized_for_charging auth_timeout |
auth_uid | e.g: 046e453af012ca3 |
time_since_charging_start | e.g: 2127 |
meter_wh | e.g: 426416 |
power_w | e.g: 3600 |
transaction_wh | e.g: 13500 |
display_text | e.g: <tariffInfoResponse> <tariffEntry> <chargeMode> <maxPower>3.7</maxPower> <currentType>AC</currentType> </chargeMode> <hourPrice>60</hourPrice> </tariffEntry> <tariffEntry> <chargeMode> <maxPower>8.0</maxPower> <currentType>AC</currentType> </chargeMode> <hourPrice>120</hourPrice> </tariffEntry> <tariffEntry> <chargeMode> <maxPower>22.0</maxPower> <currentType>AC</currentType> </chargeMode> <hourPrice>300</hourPrice> </tariffEntry></tariffInfoResponse> |
cp_id | e.g: +4983900000000001 |
ocpp_state | available occupied reserved unavailable faulted preparing charging suspendedevse suspendedev finishing |
type2_state | a b c d e |
type2_proximity | no_cable 13 20 32 63 cable_attached short_circuit |
sig_current | e.g: 16 |
schuko_state | idle connected power_on |
backend_conn_state | not_connected connecting connecting_proxy_ok connected not_reacheable rejected pending |
free_charging | off on |
slave_state | available occupied reserved unavailable faulted preparing charging suspendedevse suspendedev finishing |
ocpp_meter_cfg | ehz_meter_rs232 s0_meter_opto_1 s0_meter_opto_2 no_meter s0_meter_dedicated_input internal_meter modbus_meter_abb modbus_meter_eastron_sdm630 modbus_meter_eastron_sdm120_220 modbus_meter_garo_gnm3d modbus_meter_garo_gnm1d modbus_meter_garo_gm3t modbus_meter_garo_EM270 modbus_meter_finder modbus_meter_saia_ale3 modbus_meter_inepro_pro1_2 modbus_meter_inepro_pro380 modbus_meter_optec |
ocpp_meter_serial | e.g: 65465484ds |
current_a | e.g: 14.0,14.5,14.1 |
energy_man_current | e.g: 12 |
ambient_temp | e.g: +25.30 |
firmware_ver | e.g: 5.33.5-21150 |
cc_serial_n | e.g: 1703512493/b94060007 |
manuf_serial_n | e.g: 1703512493 |
con_cycles_schuko | e.g: 560 |
con_cycles_type2 | e.g: 1450 |
max_current | e.g: 32 |
rcmb_state | triggered okay |
rcmb_max | e.g: 0.0, 0.0 |
rcmb_values | e.g: 0.0, 0.0 |
cable_attached | off on |
schuko_cfg | disable enable |
rcd_state | disable triggered okay |
mcb_type2_state | disable triggered okay |
mcb_schuko_state | disable triggered okay |
cp_vendor | e.g: Bender GmbH Co. KG |
errors | e.g: plug_locking_failed;;rfid_reader_not_communicating |
cp_model | e.g: CC612_2M3PR |
voltage_v | e.g: 230,230,230 |
wlan_state | wlan_disconnected wlan_connected |
7. Modbus Slave Registers
Description: This section provides details for the Modbus Slave Registers tab extracted from the documentation HTML.
Reg. Type | Address | Name | R/W | Nr. Regs. | Description |
---|---|---|---|---|---|
Holding | 1000 | Charge Point State | R | 1 | |
Holding | 1001 | Charge State | R | 1 | |
Holding | 1002 | EVSE State | R | 1 | |
Holding | 1004 | Cable State | R | 1 | |
Holding | 1006 | EVSE Error Code | R | 1 | |
Holding | 1008 | Current L1 | R | 1 | Returns the current of phase 1 of the ocpp meter in mA. |
Holding | 1010 | Current L2 | R | 1 | Returns the current of phase 2 of the ocpp meter in mA. |
Holding | 1012 | Current L3 | R | 1 | Returns the current of phase 3 of the ocpp meter in mA. |
Holding | 1020 | Active Power | R | 2 | |
Holding | 1024 | Active Power L1 | R | 2 | |
Holding | 1028 | Active Power L2 | R | 2 | |
Holding | 1032 | Active Power L3 | R | 2 | |
Holding | 1036 | Energy | R | 2 | |
Holding | 1100 | Hardware current limit | R | 1 | |
Holding | 1102 | Minimum current limit | R | 1 | |
Holding | 1104 | Max. Current from EVSE | R | 1 | |
Holding | 1106 | Max. Current from Cable | R | 1 | |
Holding | 1108 | Max. Current from EV | R | 1 | |
Holding | 1200 | User priority | R | 1 | |
Holding | 1300 | EV Battery State (% 0-100) | R | 1 | Returns an estimate of the SoC |
Holding | 1302 | EV Battery Capacity (Wh) | R | 2 | Returns an estimate of the EV Battery Capacity |
Holding | 1400 | Schedule Type | R | 1 | |
Holding | 1402 | Required Energy (Wh) | R | 2 | |
Holding | 1406 | Required Battery State (% 0-100) | R | 1 | |
Holding | 1408 | Scheduled Time (hhmmss) | R | 2 | |
Holding | 1412 | Scheduled Date (yymmdd) | R | 2 | |
Holding | 1502 | Charged Energy (Wh) | R | 1 | Sum of charged energy for the current session |
Holding | 1504 | Start Time (hhmmss) | R | 2 | Start time of charging process |
Holding | 1508 | Charging Time (seconds) | R | 2 | Duration since beginning of charge |
Holding | 1512 | End Time (hhmmss) | R | 2 | End time of charging process |
Holding | 1600 | User ID | R | 2 | User ID (OCPP IdTag) from the current session. Bytes 0 to 3. |
Holding | 1602 | User ID | R | 2 | User ID (OCPP IdTag) from the current session. Bytes 4 to 7. |
Holding | 1604 | User ID | R | 2 | User ID (OCPP IdTag) from the current session. Bytes 8 to 11. |
Holding | 1606 | User ID | R | 2 | User ID (OCPP IdTag) from the current session. Bytes 12 to 15. |
Holding | 1608 | User ID | R | 2 | User ID (OCPP IdTag) from the current session. Bytes 16 to 19. |
Holding | 1620 | 15118 Smart vehicle detected | R | 1 | Returns 1 if an EV currently connected is a smart vehicle, or 0 if no EV connected or it is not a smart vehicle |
Holding | 2000 | Safe Current (Amps.) | R/W | 1 | Max. charge current under communication failure |
Holding | 2002 | Comm. Timeout (seconds) | R/W | 1 | Communication timeout |
Holding | 5000 | Charge Power (W) | W | 2 | |
Holding | 5004 | Charge Current (A) | W | 1 | |
Holding | 5006 | Charge Control | 1 | Unimplemented | |
Holding | 5008 | Charge Release | 1 | Unimplemented | |
Holding | 5900 | Free Charging | R/W | 1 | Unimplemented |
Holding | 5902 | Free Charging Mode | R/W | 1 | Unimplemented |
Holding | 6000 | Life Bit | R/W | 1 | 0/1 Toggle-Bit |
8. Logging Components
Description: This section provides details for the Logging Components tab extracted from the documentation HTML.
Component number | Component name |
---|---|
0 | DEFAULT |
1 | LOGGING |
2 | DLM |
3 | PIC24 |
4 | SLAC |
5 | GPIO |
6 | MONITORING |
7 | QCA700X_FLASH |
8 | RCMB |
9 | METER |
10 | METER_EHZ |
11 | METER_S0 |
12 | METER_INTERNAL |
13 | METER_MODBUS |
14 | SQL |
15 | RFID |
16 | LOG_FILE |
17 | SYSCLOCK |
18 | SOCKETTYPE2 |
19 | SCHUKO |
20 | OCPP |
21 | GSM |
22 | P15118 |
23 | VEHICLEIF |
24 | ASN1 |
25 | HUMIDITY_SENSOR |
26 | NOR_STORE |
27 | ETHREAD |
28 | EEVT |
29 | MK_PIC24 |
30 | TIMER_POOL |
31 | COMPONENT_MGR |
32 | PLUG |
33 | I2C |
34 | AUTH_INPUT |
35 | HW_VARIANT_MGR |
36 | WEB_INTERFACE |
37 | WEB_INTERFACE_NG |
38 | STM32_EO |
39 | EICHRECHT |
40 | HEMS |
41 | BACKEND |
42 | ERROR_HANDLING |
43 | HMI |
44 | MASTER_SLAVE |
45 | PROTOCOLS |
46 | PARAMETERS |
47 | WEBDATA |
48 | NTP |
49 | MODBUS_RTU |
50 | MODBUS_DEVICE |
51 | TIMEZONE |
52 | CCS_MODE4 |
53 | USB_HOTPLUG |
54 | USBLIB_MOD |
55 | METER_DC_DZG |
56 | STM32_HMI |
57 | MS_COMM |
58 | SU_COMM |
59 | WS_SERVER |
60 | ENERGY_MAN |
61 | ALL |