Skip to main content
v5.33
operator
manufacturer
Last updated on

OCPP parameter table

This table is intended for Charging Station manufacturers to gather an overview of all parameters that are configurable or readable over OCPP.
Operators can access the embedded OCPP documentation tables through the Charge Controller's Config UI at: http://[controller-ip]/documentationOCPP Keys and OCPP Keys Mapping.

The reference includes:

  • All standard OCPP 1.6 parameters
  • Vendor-specific extensions (DLM, master-slave, Eichrecht)
  • Scope classifications (Both, Individual, Master)
  • Data types and default values
  • Config UI mappings
tip

Read up on parameter scopes here if unfamiliar.

Parameter Name
/Persistency Filename
Info
Connector Scope
Availability
Reboot Needed
Read-Write Permissions
Possible Values
Standard/Vendor
#
APN
APN_custom
Access Point Name of the mobile network to be used when establishing connections to the backend syst
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
APNPassword
APNPassword_custom
Password to be used for authenticating with the Access Point of the mobile network for connecting wi
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
APNUsername
APNUsername_custom
Username to be used for authenticating with the Access Point of the mobile network for connecting wi
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
ASKIoverOCPP
ASKIoverOCPP_custom
Enable or disable support for receiving OCPP 1.5 SOAP 'Change Configuration Requests' for the LaMa p
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
ASKIoverOCPPAllowedIP
ASKIoverOCPPAllowedIP_custom
Configure a single IP address here that will be allowed to access the 'ASKI over OCPP-S' service. An
Both
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
AdcCpCalibrationCfg
AdcCpCalibrationCfg_custom
This parameter allows to enable the ADC calibration for the control pilot line's states detection. O
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • (2) Recalibrate
  • Default: Off
Vendor
#
AllowLongOcppGetConfKeys
AllowLongOcppGetConfKeys_custom
Allows OCPP keys in get configuration command to be longer than 500 characters.
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
AllowOfflineTxForUnknownId
AllowOfflineTxForUnknownId_custom
This parameter determines whether a client is allowed to charge in case its authorization cannot be
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • (2) ImmediatelyWhenPlugged
  • Default: Off
Standard
#
AmbientCpuDelta
AmbientCpuDelta_custom
Temperature delta for measurements from temperature sensor. This value should be tuned according to
Individual
Config UI + OCPP
No
Read-only
[0..150] Default: 23
Vendor
#
AuthorizationCacheEnabled
AuthorizationCacheEnabled_custom
Enables the use of the internal whitelist for storing RFID UID from the OCPP backend. If disabled, R
Master
Config UI + OCPP
No
Read-write
[0..1] Default: On
Standard
#
AuthorizationInput
AuthorizationInput_custom
Input used for authorization from an external switch/relay. If triggered, an AuthorizeRequest with a
Not relevant
Config UI + OCPP
Yes
Read-only
  • (0) Disable
  • (1) Enable 'Opto 1 In'
  • Default: Disable
Vendor
#
AuthorizationInputMode
AuthorizationInputMode_custom
Set if the authorization input can just start or it can both start and stop a transaction. Note that
Not relevant
Config UI + OCPP
Yes
Read-only
  • (0) Only start
  • (1) Start and stop
  • (2) Only stop
  • (3) Charging while active
  • Default: Only start
Vendor
#
AuthorizationInputType
AuthorizationInputType_custom
Set if the authorization input switch is normally open or normally closed. Note that Scheidt&Bac
Not relevant
Config UI + OCPP
Yes
Read-only
  • (0) Normally open
  • (1) Normally closed
  • Default: Normally open
Vendor
#
AuthorizeRemoteTxRequests
AuthorizeRemoteTxRequests_custom
This parameter determines whether a remote request to start a transaction in the form of a RemoteSta
Both
Config UI + OCPP
Yes
Read-write
[0..1] Default: On
Standard
#
Autocharge
Autocharge_custom
Autocharge is an experimental and non-standard feature. Some vehicles may not work or show a chargin
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
AvailableNetworks
AvailableNetworks_custom
List of network operators that are available and visible using the currently selected antenna. This
Master
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
BackendConnectionTimeout
BackendConnectionTimeout_custom
The time in seconds that is used for establishing an APN connection, establishing a Proxy or establi
Master
Config UI + OCPP
Yes
Read-write
[3..300] Default: 60
Vendor
#
BannerEnabled
BannerEnabled_custom
A Banner SureCross DX80-PB2 gateway can be connected via the charging station's external Modbus RTU
Not relevant
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
BannerMaxNodeId
BannerMaxNodeId_custom
Parking sensors are integrated in the gateway with a consecutive number. The gateway has the number
Not relevant
Config UI + OCPP
Yes
Read-write
[0..47] Default: 0
Vendor
#
BannerPollInterval
BannerPollInterval_custom
Specifies the interval in seconds at which the charging station retrieves sensor data from the gatew
Not relevant
Config UI + OCPP
Yes
Read-write
[0..4294967295] Default: 20
Vendor
#
BannerReadAnalog
BannerReadAnalog_custom
For testing and analysis purposes, raw analogue data from the parking sensor can be transmitted to t
Not relevant
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
BannerSendInterval
BannerSendInterval_custom
Specifies the interval in seconds at which sensor data is sent to the OCPP backend. The send interva
Not relevant
Config UI + OCPP
Yes
Read-write
[0..4294967295] Default: 60
Vendor
#
CPDiodeDetection
CPDiodeDetection_custom
Set this value to 'On' if you want to check before charging if the diode connected to the control pi
Individual
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
CableAttached
CableAttached_custom
Setting this to on indicates that the charger has a fixed cable attached and does NOT need to lock a
Not relevant
Config UI + OCPP
Yes
Read-only
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
CellID
CellID_custom
Cell ID as reported by the built-in modem, this value can be used to determine the location of the C
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 4294967295
Vendor
#
CentralContractValidationAllowed
CentralContractValidationAllowed_custom
If this variable is true, then the contract certificate and chain will be sent to the server for val
Both
Config UI + OCPP
Yes
Read-write
[0..1] Default: On
Standard
#
CertificateStoreMaxLength
CertificateStoreMaxLength_custom
Maximum number of Root/CA certificates that can be installed in the Charge Point.
Both
Config UI + OCPP
Yes
Read-only
[0..50] Default: 50
Standard
#
ChargeBoxIdentity
ChargeBoxIdentity_custom
ID that is sent to the backend and used by the backend to identify the ChargePoint.
Individual
Config UI + OCPP
Yes
Read-write
Default: "+4983900000000001"
Vendor
#
ChargeBoxSerialNumber
ChargeBoxSerialNumber_custom
Overrides the serial number of the charge controller manufacturer. Named 'ChargeBOXSerialNumber' in
Individual
Config UI + OCPP
Yes
Read-only
Default: "Not Set"
Vendor
#
ChargePointModel
ChargePointModel_custom
Mandatory, identifies the model of the ChargePoint. Please note that this must not match a different
Not relevant
Config UI + OCPP
Yes
Read-only
Default: "CC613_ELM4PR_M"
Vendor
#
ChargePointSerialNumber
ChargePointSerialNumber_custom
Set by the charge point manufacturer, not by the controller manufacturer. Sent as 'ChargePointSerial
Master
Config UI + OCPP
Yes
Read-only
Default: "Not Set"
Vendor
#
ChargePointVendor
ChargePointVendor_custom
Mandatory, identifies the vendor of the ChargePoint.
Both
Config UI + OCPP
Yes
Read-only
Default: "Bender GmbH Co. KG"
Vendor
#
ChargeProfileMaxStackLevel
ChargeProfileMaxStackLevel_custom
Max StackLevel of a ChargingProfile.
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 255
Standard
#
ChargingScheduleAllowedChargingRateUnit
ChargingScheduleAllowedChargingRateUnit_custom
List of supported quantities for use in a ChargingSchedule.
Master
Config UI + OCPP
No
Read-only
Default: "Current"
Standard
#
ChargingScheduleMaxPeriods
ChargingScheduleMaxPeriods_custom
Maximum number of periods that may be defined per ChargingSchedule.
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 255
Standard
#
CheckCarOverCurrent
CheckCarOverCurrent_custom
If set to On the current consumed by the vehicle will be checked against the signaled current. If th
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
CheckCarOverCurrentStopLimit
CheckCarOverCurrentStopLimit_custom
When the charging current reported by the OCPP meter exceeds the signaled current by this percentage
Both
Config UI + OCPP
Yes
Read-write
[10..100] Default: 30
Vendor
#
ClockAlignedDataInterval
ClockAlignedDataInterval_custom
Interval in seconds after which a new meter value is sent to the backend system regardless of whethe
Both
Config UI + OCPP
Yes
Read-write
[0..4294967295] Default: 0
Standard
#
ClockAlignedMeterRandomSendDelay
ClockAlignedMeterRandomSendDelay_custom
The sending of the clock aligned values are delayed for a random time between 0 and the configured v
Both
Config UI + OCPP
Yes
Read-write
[0..4294967295] Default: 10
Vendor
#
Config15118
Config15118_custom
High Level (15118 protocol) Power Line Communication configuration. If set to 'Off' 15118 communicat
Both
Config UI + OCPP
Yes
Read-write
(0) Off (1) On (with PlugNCharge) (2) On (no PlugNCharge) Default: Off
Vendor
#
ConnSettingsFallback
ConnSettingsFallback_custom
Restores last good connection settings when failed to reconnect to the backend after a reboot.
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
ConnectionTimeOut
ConnectionTimeOut_custom
Interval (from successful authorization) until incipient charging session is automatically canceled
Both
Config UI + OCPP
Yes
Read-write
[4..300] Default: 45
Standard
#
ConnectionType
ConnectionType_custom
The type of data connection used to connect to the backend system. Choose 'No Backend' to disable ba
Master
Config UI + OCPP
Yes
Read-write
  • (0) No Backend
  • (1) GSM
  • (2) Ethernet
  • (3) USB
  • (4) WLAN
  • Default: No Backend
Vendor
#
ConnectorEvseIds
ConnectorEvseIds_custom
Comma separated EVSEIDs for OCPP connectors starting with connector 1 in one string.
Both
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
ConnectorPhaseRotation
ConnectorPhaseRotation_custom
Both
Config UI + OCPP
No
Read-write
Default: "1.RST, 2.RST"
Standard
#
ConnectorPhaseRotationIT
ConnectorPhaseRotationIT_custom
Individual
Config UI + OCPP
No
Read-write
Default: "L1-L2"
Vendor
#
ConnectorPhaseRotationMaxLength
ConnectorPhaseRotationMaxLength_custom
Maximum number of items in a ConnectorPhaseRotation Configuration Key.
Individual
Config UI + OCPP
No
Read-only
[0..0] Default: 3
Standard
#
ConnectorSwitch3to1PhaseSupported
ConnectorSwitch3to1PhaseSupported_custom
If set the ChargePoint supports switching between 3 and 1 phases during a charging session.
Master
Config UI + OCPP
Yes
Read-only
[0..1] Default: Off
Standard
#
ContactorCyclesType2
ContactorCyclesType2_custom
The number of times the contactor of the type 2 socket was switching on and off.
Individual
Config UI + OCPP
No
Read-only
Default: "12/10,000,000"
Vendor
#
ContactorCyclesUnderloadLimit
ContactorCyclesUnderloadLimit_custom
The maximum number of contactor cycles under load before receiving a system warning
Individual
Config UI + OCPP
Yes
Read-only
[0..50000] Default: 6000
Vendor
#
ContractValidationOffline
ContractValidationOffline_custom
If this variable is true, then the Charge Point will try to validate a contract certificate when it
Both
Config UI + OCPP
Yes
Read-write
[0..1] Default: On
Standard
#
CurrentDirSecondL1
CurrentDirSecondL1_custom
If set to 'Inverted', the current and power value reported by the second meter in line 1 will be inv
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Standard
  • (1) Inverted
  • (2) Suppress-signed
  • Default: Standard
Vendor
#
CurrentDirSecondL2
CurrentDirSecondL2_custom
If set to 'Inverted', the current and power value reported by the second meter in line 2 will be inv
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Standard
  • (1) Inverted
  • (2) Suppress-signed
  • Default: Standard
Vendor
#
CurrentDirSecondL3
CurrentDirSecondL3_custom
If set to 'Inverted', the current and power value reported by the second meter in line 3 will be inv
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Standard
  • (1) Inverted
  • (2) Suppress-signed
  • Default: Standard
Vendor
#
DataConsumption
DataConsumption_custom
Data Consumption (in bytes) for the running month.
Master
Config UI + OCPP
No
Read-write
[0..9223372036854775807] Default: 0
Vendor
#
DataConsumptionLastMonth
DataConsumptionLastMonth_custom
Data Consumption (in bytes) for the previous month.
Master
Config UI + OCPP
No
Read-write
[0..9223372036854775807] Default: 0
Vendor
#
DataTransferTariffUsage
DataTransferTariffUsage_custom
Enables the DataTransfer messages that allow to show Tariff and Total Usage Information. Beware this
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DaysScheduledReboots
DaysScheduledReboots_custom
Number of days that is used for house keeping reboots. The charge controller reboots after the numbe
Both
Config UI + OCPP
No
Read-write
[1..30] Default: 30
Vendor
#
DepartureTime
DepartureTime_custom
Used to indicate when the vehicle intends to finish the charging process.
Individual
Config UI + OCPP
No
Read-only
Default: "Not Available"
Vendor
#
DisplayContentSelectorEnergy
DisplayContentSelectorEnergy_custom
If enabled the display shows charging energy information.
Not relevant
Config UI + OCPP
No
Read-only
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
DisplayContentSelectorPower
DisplayContentSelectorPower_custom
If enabled the display shows charging power information.
Not relevant
Config UI + OCPP
No
Read-only
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DisplayContentSelectorTime
DisplayContentSelectorTime_custom
If enabled the display shows charging time information.
Not relevant
Config UI + OCPP
No
Read-only
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
DisplayDisconnectAsError
DisplayDisconnectAsError_custom
Parameter that determines whether an error is signaled to the user when the backend connection is in
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DisplayLanguage
DisplayLanguage_custom
The language of display texts on the LCD display, if available. Only has an effect if a LCD is confi
Individual
Config UI + OCPP
No
Read-write
  • (0) English
  • (1) Deutsch/German
  • (2) Italiano/Italian
  • (3) Slovenský/Slovak
  • (4) Multi-Language EN-DE-FR-NL
  • (5) SR Multi-Language EN-DE-FR-IT
  • Default: Multi-Language EN-DE-FR-NL
Vendor
#
DisplayMode
DisplayMode_custom
Controls the display mode. When set to 'Master/Slave', the display shows independent states for mast
Not relevant
Config UI + OCPP
No
Read-only
(0) Main (Master) (1) Master/Slave Default: Main (Master)
Vendor
#
DisplayType
DisplayType_custom
Type of display connected to the ChargePoint (if any).
Not relevant
Config UI + OCPP
No
Read-only
  • (0) Display not configured
  • (1) Display not in use
  • (2) Bender LCD-Module DPM2x16FP
  • Default: Display not configured
Vendor
#
DlmClearPersistentSlaves
DlmClearPersistentSlaves_custom
Select 'Clear' and 'Save' to clear the database of known DLM slaves
Master
Config UI + OCPP
No
Read-write
  • (0) -
  • (1) Clear
  • Default: -
Vendor
#
DlmCurrImbalanceLim
DlmCurrImbalanceLim_custom
Maximum allowed phase imbalance. DLM will not exceed the 'Current Imbalance Limit' between phases wh
Master
Config UI + OCPP
Yes
Read-write
[0..255] Default: 20
Vendor
#
DlmCurrImbalancePreventionEnabled
DlmCurrImbalancePreventionEnabled_custom
If enabled, DLM will not exceed the 'Current Imbalance Limit' configured.
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DlmDisableDiscoveryBroadcast
DlmDisableDiscoveryBroadcast_custom
Disables the broadcasting of DLM Discovery beacons in the DLM master. If disabled, DLM slaves will n
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DlmDisconnectedLimit
DlmDisconnectedLimit_custom
Current limit when disconnected from DLM network.
Both
Config UI + OCPP
Yes
Read-write
[0..100] Default: 6
Vendor
#
DlmDiscoveryNetworkId
DlmDiscoveryNetworkId_custom
Several DLM groupings might coexist in one physical LAN. In case of DLM Master-Auto-Discovery, they
Master
Config UI + OCPP
Yes
Read-write
[0..255] Default: 0
Vendor
#
DlmExtLoadAvgLen
DlmExtLoadAvgLen_custom
Meter values will be averaged in order to avoid transients.
Master
Config UI + OCPP
Yes
Read-write
[2..3600] Default: 5
Vendor
#
DlmExtMeterEnabled
DlmExtMeterEnabled_custom
If enabled, an external, secondary meter allows to also consider the power consumption of additional
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DlmExtMeterLocation
DlmExtMeterLocation_custom
Specifies how the external meter is connected depending on its location. Either at the grid entry po
Master
Config UI + OCPP
Yes
Read-write
  • (0) Grid
  • (1) External Load
  • (2) Renewable Production
  • Default: Grid
Vendor
#
DlmHierarchicalMode
DlmHierarchicalMode_custom
If selected, this node will function as the DLM Coordinator (i.e. the "central" node) of the hierarc
Master
Config UI + OCPP
Yes
Read-write
(0) Disabled (1) Enabled (with local MQTT broker) (2) Enabled (with remote MQTT broker) Default: Disa...
Vendor
#
DlmInput1CurrOffsetCfg
DlmInput1CurrOffsetCfg_custom
Adds a configurable offset to 'EVSE Sub-Distribution Limit' based on GPI External Input 1.
Master
Config UI + OCPP
Yes
Read-write
  • (0) Disable
  • (1) Enable 'Opto 1 In'
  • Default: Disable
Vendor
#
DlmInput1Polarity
DlmInput1Polarity_custom
Changes the polarity of the input signal 1. "Active high" does not change the polarity, "Active low"
Master
Config UI + OCPP
Yes
Read-write
  • (0) Active high
  • (1) Active low
  • Default: Active high
Vendor
#
DlmInput3CurrOffsetCfg
DlmInput3CurrOffsetCfg_custom
Adds a configurable offset to 'EVSE Sub-Distribution Limit' based on the Meter's Digital Input regis
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DlmMasterIp
DlmMasterIp_custom
DLM Master IP which is used for DLM-Slaves configured with Master-Fixed-IP. Additionally the connect
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
DlmMinCurrentRating
DlmMinCurrentRating_custom
Minimum current limit that charging should not go below.
Both
Config UI + OCPP
Yes
Read-write
[6..100] Default: 6
Vendor
#
DlmMode
DlmMode_custom
Specifies the ChargePoint's role in a DLM network. There MUST be exactly one DLM Master in a DLM net
Individual
Config UI + OCPP
Yes
Read-write
(0) Disabled (1) DLM Master (With internal DLM-Slave) (2) DLM Master (Standalone) (3) DLM Slave (...
Vendor
#
DlmPersistentSlavesCount
DlmPersistentSlavesCount_custom
Number of persistent DLM slaves registered in DLM slave database
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 1
Vendor
#
DlmRecalcInterval
DlmRecalcInterval_custom
The DLM algorithm will not calculate and re-assign current to its DLM slaves any faster than at this
Master
Config UI + OCPP
No
Read-write
  • (1) 1 sec
  • (2) 2 sec
  • (5) 5 sec
  • (15) 15 sec
  • (30) 30 sec
  • (60) 1 min
  • (600) 10 min
  • (999) 15 min
  • Default: 30 sec
Vendor
#
DlmSlaveSolarEnabled
DlmSlaveSolarEnabled_custom
This parameter is used to signal to the DLM master that the charging station is participating in sol
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DlmSolarMode_dlm
DlmSolarMode_dlm_custom
This DLM feature allows EVs on a group of DLM clients to be charged with excess PV power. Activate s
Master
Config UI + OCPP
No
Read-write
  • (0) DLM standard
  • (1) PV surplus
  • (3) PV surplus + grid support
  • Default: DLM standard
Vendor
#
DlmState
DlmState_custom
DLM State
Individual
Config UI + OCPP
No
Read-only
Default: "Role: DLM Master (with internal slave), 0 slave(s) connected"
Vendor
#
DlmTimeTableScheduleRandomization
DlmTimeTableScheduleRandomization_custom
Delay the scheduled activation of a specified current limit by a random number of seconds between 0
Not relevant
Config UI + OCPP
No
Read-write
[0..1800] Default: 0
Vendor
#
DlmcAddress
DlmcAddress_custom
DlmcAddress
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
DlmcMqttBrokerAddress
DlmcMqttBrokerAddress_custom
The IP address for the broker. On one of the controllers in the hierarchical DLM network has to be r
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
DlmcMqttBrokerPort
DlmcMqttBrokerPort_custom
The port on which this controller connects to the MQTT broker. The default is 8883.
Master
Config UI + OCPP
Yes
Read-write
[1024..65535] Default: 8883
Vendor
#
DlmcPublishConstraints
DlmcPublishConstraints_custom
When enabled the constraints will be published to the MQTT broker
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
DualLedMode
DualLedMode_custom
Behavior for dual LED boards. When set to 'On', the dual LED board shows independent states of maste
Not relevant
Config UI + OCPP
No
Read-only
  • (0) Off
  • (1) On
  • (2) On Inverted
  • Default: Off
Vendor
#
EAmount
EAmount_custom
Amount of energy reflecting the EV's estimate of how much energy is needed to fulfill the user confi
Individual
Config UI + OCPP
No
Read-only
Default: "Not Available"
Vendor
#
EEBUSCommunicationTimeout
EEBUSCommunicationTimeout_custom
If the charging station cannot reach the energy manager for longer than set, the connection is consi
Master
Config UI + OCPP
No
Read-write
[4..3600] Default: 4
Vendor
#
EEBUSConfigCevcOnOff
EEBUSConfigCevcOnOff_custom
Compatible energy managers can control the charging station via the EEBus interface.
Master
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
EEBUSConfigOnOff
EEBUSConfigOnOff_custom
Compatible energy managers can control the charging station via the EEBus interface.
Master
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
EEBUSEnableKeoLogging
EEBUSEnableKeoLogging_custom
Enable logging of KEO stack messages
Master
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
EEBUSFallbackCurrent
EEBUSFallbackCurrent_custom
If the connection to the energy manager fails, the charging current is set to the value set here. Se
Master
Config UI + OCPP
No
Read-write
[6..80] Default: 6
Vendor
#
EEBUSModuleShipId
EEBUSModuleShipId_custom
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
EEBUSModuleVersion
EEBUSModuleVersion_custom
Master
Config UI + OCPP
No
Read-write
[0..4294967295] Default: 0
Vendor
#
EEBUSPairedCemId
EEBUSPairedCemId_custom
Identifier issued by the coupled energy manager for identification purposes.
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
EEBUSPairedCemIp
EEBUSPairedCemIp_custom
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
EEBUSPairedCemModelName
EEBUSPairedCemModelName_custom
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
EEBUSPairedCemSki
EEBUSPairedCemSki_custom
Subject Key Identifier of the coupled energy manager for identification purposes.
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
EEBUSPairedCemUri
EEBUSPairedCemUri_custom
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
EEBusLPCFailsafeDurationMinEnergyGuard
EEBusLPCFailsafeDurationMinEnergyGuard_custom
The minimum duration that the system will remain in the failsafe state if the connection to the ener
Individual
Config UI + OCPP
No
Read-write
[7200..86400] Default: 7200
Vendor
#
EEBusLPCFailsafeDurationMinUser
EEBusLPCFailsafeDurationMinUser_custom
The minimum duration that the system will remain in the LPC failsafe state if the connection to the
Master
Config UI + OCPP
No
Read-write
[7200..86400] Default: 7200
Vendor
#
EEBusLPCFailsafePowerEnergyGuard
EEBusLPCFailsafePowerEnergyGuard_custom
If the connection to the energy manager fails, the power is set to the value set by the energy guard
Individual
Config UI + OCPP
No
Read-write
[0..66000] Default: 11040
Vendor
#
EEBusLPCFailsafePowerUser
EEBusLPCFailsafePowerUser_custom
If the connection to the energy manager fails, the failsafe power for LPC is set to the value set he
Master
Config UI + OCPP
No
Read-write
[0..66000] Default: 11040
Vendor
#
EOActuatorType
EOActuatorType_custom
Configure the connected actuator type
Not relevant
Config UI + OCPP
Yes
Read-only
  • (0) Mennekes Standard
  • (2) Phoenix
  • (3) Kuester Gen2
  • Default: Mennekes Standard
Vendor
#
EVMACAddr
EVMACAddr_custom
EV's MAC address.
Individual
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
EVSEMaxCur
EVSEMaxCur_custom
Value sent to the EV on Charging Status messages during the charging loop.
Individual
Config UI + OCPP
No
Read-only
Default: "Not Available"
Vendor
#
EichrechtState
EichrechtState_custom
Eichrecht State
Individual
Config UI + OCPP
No
Read-only
Default: "System without Eichrecht"
Vendor
#
EichrechtTransactionMessageAttempts
EichrechtTransactionMessageAttempts_custom
Sets how often the ChargePoint tries to submit an Eichrecht transaction-related message when the bac
Individual
Config UI + OCPP
Yes
Read-write
[-1..5] Default: 0
Vendor
#
EnergyManInputPowerCurrentLim
EnergyManInputPowerCurrentLim_custom
Single phase RMS current limit (in A) for energy management from external input. Range: from 6 A to
Individual
Config UI + OCPP
Yes
Read-write
[0..80] Default: 16
Vendor
#
EnergyManInputPowerLimitCfg
EnergyManInputPowerLimitCfg_custom
Enables energy Management from external input
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Disable
  • (1) Enable 'Opto 1 In'
  • Default: Disable
Vendor
#
EnforcePwdChange
EnforcePwdChange_custom
Force change of default operator password on login.
Both
Config UI + OCPP
No
Read-only
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
EnforceStrongLoginPwds
EnforceStrongLoginPwds_custom
Force selecting a strong secure login password when changing the operator password, the installer pa
Both
Config UI + OCPP
No
Read-only
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
ErrorResolution
ErrorResolution_custom
List of error resolutions currently present in the ChargePoint.
Individual
Config UI + OCPP
No
Read-only
Default: "Error resolution will be displayed for every active error."
Vendor
#
ErrorStatusNotifications
ErrorStatusNotifications_custom
This parameter determines whether OCPP status notifications that are meant to report and error (such
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
ErrorsList
ErrorsList_custom
List of errors currently present in the ChargePoint.
Individual
Config UI + OCPP
No
Read-only
Default: "No errors"
Vendor
#
EventsList
EventsList_custom
List of the last events and errors with their timestamp.
Individual
Config UI + OCPP
No
Read-only
Default: "Thu, 01 Jan 00:00:47 1970 : Unintended Reset - Power Outage? "
Vendor
#
FirmwareVersion
FirmwareVersion_custom
Firmware version running on the ChargePoint.
Individual
Config UI + OCPP
No
Read-only
Default: "5.33.5-21150"
Vendor
#
ForceHeartbeatRequestMessages
ForceHeartbeatRequestMessages_custom
Sets if the Charge Point should send OCPP Heartbeat request messages despite other messages being se
Not relevant
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
FreeCharging
FreeCharging_custom
Allows charging without authorization via RFID or the backend. Charging is started immediately after
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
FreeChargingMode
FreeChargingMode_custom
Sets the OCPP behavior in free charging mode. Note that in case of a master/slave scenario the slave
Both
Config UI + OCPP
Yes
Read-write
  • (0) No OCPP
  • (1) With OCPP status notif without auth
  • (2) With OCPP status notif with auth
  • (3) With OCPP Full fixed RFID with auth
  • (4) With OCPP Full fixed RFID without auth
  • (5) With OCPP Full any RFID
  • Default: No OCPP
Vendor
#
GSMPPPMTU
GSMPPPMTU_custom
Maximum transmission unit size for GSM connections (in bytes)(valid value range: 68 - 1492).
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
GSMState
GSMState_custom
Registration state to the mobile network.
Master
Config UI + OCPP
No
Read-only
  • (0) Not Registered and Not Searching
  • (1) Registered at Home Network
  • (2) Not Registered and Searching
  • (3) Registration Denied
  • (4) Unknown
  • (6) Not Available
  • Default: Not Available
Vendor
#
GSMStateInfo
GSMStateInfo_custom
Status of the GSM connection such as APN name, network type (LTE, EDGE), frequency/band (e.g. band 7
Master
Config UI + OCPP
No
Read-only
Default: "Unknown APN (Not Available | Unknown band | RSSI: ≤ -113 dBm | SINR..."
Vendor
#
GeolocationUpdate
GeolocationUpdate_custom
Request or update the geolocation data
Master
Config UI + OCPP
No
W
N/A
Vendor
#
GetConfigurationMaxKeys
GetConfigurationMaxKeys_custom
Maximum number of requested configuration keys in a GetConfiguration.req PDU.
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 366
Standard
#
GetCountContactorCyclesType2UnderLoad
GetCountContactorCyclesType2UnderLoad_custom
The number of times the contactor was switching on and off under load.
Individual
Config UI + OCPP
No
Read-only
Default: "1/6,000"
Vendor
#
GiroEEnable
GiroEEnable_custom
Enables or disables the GiroCard payment via Giro-e over OCPP. Requires a Giro-e capable OCPP backen
Individual
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
HTBSendMeterPublicKey
HTBSendMeterPublicKey_custom
Set whether to send the meter's public key to backend. If 'On', the meter's public key gets embedded
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
HTTPBasicAuthPassword
HTTPBasicAuthPassword_custom
The password to be used for HTTP Basic Authorization. If left empty, HTTP Basic Authorization is not
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
HardwareCurrentLimit
HardwareCurrentLimit_custom
Maximum current (in Amperes) the charge point hardware can support
Individual
Config UI + OCPP
Yes
Read-only
[0..80] Default: 16
Vendor
#
HeartbeatInterval
HeartbeatInterval_custom
The interval in seconds with which OCPP heartbeat messages are sent to the backend system. Modifying
Master
Config UI + OCPP
No
Read-write
[10..86400] Default: 240
Standard
#
HemsConfigChargeCompleteTime
HemsConfigChargeCompleteTime_custom
This value configures the time of day until the charging process should be completed. At least the m
Master
Config UI + OCPP
No
Read-write
Default: "08:00"
Vendor
#
HemsConfigChargingMode
HemsConfigChargingMode_custom
This option allows to select the charging mode used by the EEBus system."Mains charging" configures
Master
Config UI + OCPP
No
Read-write
  • (0) Mains charging
  • (1) Solar charging
  • (2) Solar surplus charging
  • Default: Mains charging
Vendor
#
HemsConfigMaxEnergyDemand
HemsConfigMaxEnergyDemand_custom
This value sets the maximum energy demand that is reported to the Energy Manager for the charging po
Master
Config UI + OCPP
No
Read-write
[1..1000] Default: 30
Vendor
#
HemsConfigMinEnergyDemand
HemsConfigMinEnergyDemand_custom
This value sets the minimum amount of energy that is reported to the Energy Manager for the charge p
Master
Config UI + OCPP
No
Read-write
[0..1000] Default: 5
Vendor
#
HemsConfigOptEnergyDemand
HemsConfigOptEnergyDemand_custom
This value sets the optimal amount of energy that is reported to the Energy Manager for the charge p
Master
Config UI + OCPP
No
Read-write
[0..1000] Default: 8
Vendor
#
HemsDeviceName
HemsDeviceName_custom
Allows the configuration of an HEMS-specific device name for systems such as EEBus or SEMP. Please n
Master
Config UI + OCPP
Yes
Read-write
Default: "CC613_ELM4PR_M"
Vendor
#
HostnameBinaryOCPP
HostnameBinaryOCPP_custom
The DNS hostname or IP address of the binary ocpp proxy server for the backend system. This paramete
Master
Config UI + OCPP
Yes
Read-write
Default: "be.elinc.de"
Vendor
#
ICCID
ICCID_custom
Integrated Circuit Card Identifier (ICCID) of the SIM card inserted into the built-in modem.
Master
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
IMEI
IMEI_custom
International Mobile Equipment Identification (IMEI). A number associated with the hardware of the b
Master
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
IMSI
IMSI_custom
International Mobile Subscriber Identity (IMSI), a value associated with the SIM card inserted into
Master
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
ISO15118PnCEnabled
ISO15118PnCEnabled_custom
If this variable set to true, then the Charge Point supports ISO 15118 plug and charge messages via
Both
Config UI + OCPP
No
Read-write
[0..1] Default: Off
Standard
#
InfoStatusNotifications
InfoStatusNotifications_custom
This parameter determines whether OCPP status notifications that are meant just for informative purp
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
InputChangeNotifyBackend
InputChangeNotifyBackend_custom
Changes on inputs 1 and 2 will issue a status notification message to backend limited to not more th
Both
Config UI + OCPP
No
Read-only
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
InputOutputBackendControlledMode
InputOutputBackendControlledMode_custom
Inputs (InputOptoC65 and InputOptoC87 on CC612 or InputOpto1 and InputOpto2 on others) and output (O
Both
Config UI + OCPP
Yes
Read-only
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
InterfacesList
InterfacesList_custom
List of interfaces and their IPs
Master
Config UI + OCPP
No
Read-only
Default: "eth0: [E0:AE:B2:02:E9:8F] IP: 10.13.208.20 (ocpp)"
Vendor
#
LAC
LAC_custom
Location Area Code as reported by the built-in modem, this value can be used to determine the locati
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 4294967295
Vendor
#
LAI
LAI_custom
Location Area Identity (LAI), composed of Mobile Country Code (MCC), Mobile Network Code (MNC) and L
Master
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
LASTWRONGSIMPIN
LASTWRONGSIMPIN_custom
The wrong PIN number that was used last time.
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
LaMa_ConnectionRate
LaMa_ConnectionRate_custom
Secret key for Mennekes EnergyManager Input
Individual
Config UI + OCPP
No
Read-write
[0..100000] Default: 16
Vendor
#
LedType
LedType_custom
Type of LED device connected to the ChargePoint (if any).
Not relevant
Config UI + OCPP
No
Read-only
  • (1) LED ring device
  • (2) LED ring device with RFID always shown
  • (3) LED ring with free charging
  • (7) No LED
  • Default: LED (default)
Vendor
#
LightIntensity
LightIntensity_custom
Value range is 0 to 100
Both
Config UI + OCPP
No
Read-write
[0..100] Default: 100
Standard
#
LocalAuthListEnabled
LocalAuthListEnabled_custom
Selects if the Local Authorization List is enabled
Master
Config UI + OCPP
No
Read-write
[0..1] Default: Off
Standard
#
LocalAuthListMaxLength
LocalAuthListMaxLength_custom
Maximum number of identifications that can be stored in the Local Authorization List
Master
Config UI + OCPP
No
Read-only
[0..1000000] Default: 1000000
Standard
#
LocalAuthorizeOffline
LocalAuthorizeOffline_custom
Sets if the Charge Point, when offline, will start transactions for locally authorized identifiers.
Master
Config UI + OCPP
No
Read-write
[0..1] Default: On
Standard
#
LocalPreAuthorize
LocalPreAuthorize_custom
Sets if the Charge Point, when online, will start transactions for locally authorized identifiers wi
Master
Config UI + OCPP
No
Read-write
[0..1] Default: On
Standard
#
LocalScheduledReboots
LocalScheduledReboots_custom
The local time of day used for house keeping reboots. The charge controller reboots after 30 days to
Both
Config UI + OCPP
Yes
Read-write
[0..23] Default: 0
Vendor
#
Log15118
Log15118_custom
Enable the creation of the '15118_log.csv' file with the input and output exi stream messages.
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
MACEVCCIDPrefix
MACEVCCIDPrefix_custom
This prefix will be inserted in the EV's MAC address when used as authorization ID against the backe
Both
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
MCC
MCC_custom
Mobile Country Code as determined from the SIM card. This tells you which country your SIM card come
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 4294967295
Vendor
#
MNC
MNC_custom
Mobile Network Code as determined from the SIM card. This tells you which mobile network operator yo
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 4294967295
Vendor
#
MODEMNETSTATE
MODEMNETSTATE_custom
Show at which state in the connection sequence the modem is currently operating. Show OK when connec
Master
Config UI + OCPP
No
Read-only
Default: "Not available"
Vendor
#
ManufacturerURL
ManufacturerURL_custom
Configures the uniform resource locator (URL) of the manufacturer. The manufacturer URL is used by v
Master
Config UI + OCPP
No
Read-only
Vendor
#
MasterSlaveMode
MasterSlaveMode_custom
'Master' controller handles the backend connection and may start and stop transaction for its slave.
Not relevant
Config UI + OCPP
Yes
Read-only
  • (0) Off
  • (1) Master
  • (2) Slave
  • Default: Off
Vendor
#
MaxChargingProfilesInstalled
MaxChargingProfilesInstalled_custom
Maximum number of Charging profiles installed at a time.
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 255
Standard
#
MaxEnergyPerSession
MaxEnergyPerSession_custom
Energy limit of the session. When Max Energy limit is reached, the session is terminated and connect
Both
Config UI + OCPP
No
Read-write
[0..100] Default: 0
Vendor
#
MaxTimePerSession
MaxTimePerSession_custom
Time limit of the session. When Max Time limit is reached, the session is terminated and connector w
Both
Config UI + OCPP
No
Read-write
[0..24] Default: 0
Vendor
#
MeterPublicKey
MeterPublicKey_custom
Public key of the cryptography engine of the connected meter used for billing if available.
Individual
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
MeterRestrictSecondaryTypes
MeterRestrictSecondaryTypes_custom
Show complete list with all meter types for load management or limit list to meter models with Modbu
Not relevant
Config UI + OCPP
Yes
Read-only
  • (0) All meter types
  • (1) Modbus TCP meters only
  • Default: All meter types
Vendor
#
MeterSerialNumber
MeterSerialNumber_custom
Serial number as reported by the eHZ or ModBus meter.
Individual
Config UI + OCPP
No
Read-write
Default: "No Id read yet"
Vendor
#
MeterValueSampleInterval
MeterValueSampleInterval_custom
Interval in seconds after which a new meter value is sent to the backend system during a charging tr
Both
Config UI + OCPP
No
Read-write
[0..99999] Default: 0
Standard
#
MeterValueSampleMode
MeterValueSampleMode_custom
According to the mode, meter values are sent under specific circumstances. 'WholeTransaction': only
Both
Config UI + OCPP
No
Read-write
  • (0) Whole transaction
  • (1) Contactor closed
  • (2) Current flow only
  • Default: Whole transaction
Vendor
#
MeterValuesAlignedData
MeterValuesAlignedData_custom
Comma-separated list of types of meter values that should be sent as clock aligned data elements in
Both
Config UI + OCPP
No
Read-write
Default: "Energy.Active.Import.Register"
Standard
#
MeterValuesSampledData
MeterValuesSampledData_custom
Comma-separated list of types of meter values that should be sent as sampled data elements in separa
Both
Config UI + OCPP
No
Read-write
Default: "Energy.Active.Import.Register"
Standard
#
ModbusSlaveAllowStartStop
ModbusSlaveAllowStartStop_custom
Allows transactions to be started/stopped from a Modbus Master device via the controller's Modbus TC
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
ModbusSlaveAllowUIDDisclose
ModbusSlaveAllowUIDDisclose_custom
Allows sending the UID via the Ebee Modbus TCP Server protocol
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
ModbusSlaveCommTimeout
ModbusSlaveCommTimeout_custom
Timeout in seconds between messages with a Modbus TCP Master device
Both
Config UI + OCPP
Yes
Read-write
[1..2147483647] Default: 1200
Vendor
#
ModbusSlaveDevAddr
ModbusSlaveDevAddr_custom
Device address (0 to 255) to use for the Modbus TCP Server feature
Individual
Config UI + OCPP
Yes
Read-write
[0..255] Default: 10
Vendor
#
ModbusSlaveRegAddrSet
ModbusSlaveRegAddrSet_custom
Choose the set of register addresses that the Modbus TCP Server device will expose to its Master dev
Both
Config UI + OCPP
Yes
Read-write
  • (0) Phoenix
  • (1) TQ-DM100
  • Default: TQ-DM100
Vendor
#
ModbusSlaveTCPConfigOnOff
ModbusSlaveTCPConfigOnOff_custom
Activates the charging station's Modbus TCP Server function for connecting energy management systems
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
ModbusSlaveTCPPort
ModbusSlaveTCPPort_custom
Port number on which the Modbus TCP Server waits for incoming connections on connector 1. A second s
Master
Config UI + OCPP
Yes
Read-write
[0..65434] Default: 502
Vendor
#
ModemAccessTechnology
ModemAccessTechnology_custom
Shows which access technology (2G, 3G, 4G) the modem is currently using.
Master
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
ModemInfo
ModemInfo_custom
Shows the modem manufacturer, model and firmware revision.
Master
Config UI + OCPP
No
Read-only
Default: "Not available"
Vendor
#
ModemLastConnError
ModemLastConnError_custom
Reason for the last modem APN connection failure
Master
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
ModemNetworkOperFmt
ModemNetworkOperFmt_custom
Indicates if the operator name format is alphanumeric or numeric. Long alphanumeric format can be up
Master
Config UI + OCPP
Yes
Read-write
  • (0) Alphanumeric Long
  • (1) Alphanumeric Short
  • (2) Numeric
  • Default: Alphanumeric Short
Vendor
#
ModemNetworkSelMode
ModemNetworkSelMode_custom
In 'Automatic' mode the modem chooses the operator. In 'Manual' mode the operator specified in reque
Master
Config UI + OCPP
Yes
Read-write
  • (0) Auto
  • (1) Manual
  • (2) Manual/Auto
  • Default: Auto
Vendor
#
ModemNetworkState
ModemNetworkState_custom
The current network registration mode of the modem which informs about the technology (2G, 3G, 4G) a
Master
Config UI + OCPP
No
Read-only
  • (0) Disable
  • (1) Enable
  • (2) Enable with location
  • (3) Not Available
  • Default: Not Available
Vendor
#
ModemNetworkType
ModemNetworkType_custom
The technology to be used to access the network 2G (GSM), 3G (UTRAN) or 4G (LTE). In auto mode the m
Master
Config UI + OCPP
Yes
Read-write
  • (0) Auto
  • (1) 2G
  • (2) 3G
  • (3) 4G
  • Default: Auto
Vendor
#
MonitoringRelayInput
MonitoringRelayInput_custom
Use a unique input from a monitoring relay to trigger RCD/MCB.
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Disable
  • (2) Enable 'Opto 1 In'
  • (3) Via meter
  • Default: Disable
Vendor
#
NetworkConfigDHCPDelay
NetworkConfigDHCPDelay_custom
DHCP request delay between multiple requests in seconds.
Master
Config UI + OCPP
Yes
Read-write
[0..100000] Default: 10
Vendor
#
NetworkConfigDHCPRetries
NetworkConfigDHCPRetries_custom
DHCP request number of retries before giving up.
Master
Config UI + OCPP
Yes
Read-write
[0..100000] Default: 10
Vendor
#
NetworkConfigDHCPTimeout
NetworkConfigDHCPTimeout_custom
DHCP request timeout in seconds.
Master
Config UI + OCPP
Yes
Read-write
[0..100000] Default: 10
Vendor
#
NetworkConfigHostname
NetworkConfigHostname_custom
Network hostname used for DHCP and mDNS.
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
NetworkConfigMode
NetworkConfigMode_custom
Mode for ethernet configuration to be used for the ChargePoint. 'Auto' uses DHCP to configure the Ch
Master
Config UI + OCPP
Yes
Read-write
  • (1) Static
  • (2) DHCP server
  • Default: Auto (DHCP client)
Vendor
#
NumberOfConnectors
NumberOfConnectors_custom
Number of physical charging connectors of this Charge Point.
Master
Config UI + OCPP
No
Read-only
[0..0] Default: 1
Standard
#
OCPPBackendJSONURL
OCPPBackendJSONURL_custom
The WS/WSS URL of the OCPP backend system. This URL must be the WS/JSON endpoint and begin with "ws:
Master
Config UI + OCPP
Yes
Read-write
Default: "ws://be.elinc.de:8080/OCPPJProxyQA/v16/"
Vendor
#
OCPPMeterType
OCPPMeterType_custom
Type of meter used for the charging socket and its connector. This is relevant for OCPP transactions
Individual
Config UI + OCPP
Yes
Read-only
  • (73) eHZ Meter via USB
  • (75) eHZ-B Meter via USB
  • (6) Modbus Meter ABB
  • (47) Modbus ABB EV3
  • (44) Modbus Berg B23
  • (43) Modbus Berg BME 461
  • (19) Modbus TQ EM300-LR
  • (41) Modbus TQ EM410/EM420
  • (86) Modbus Meter Carlo Gavazzi EM111/112
  • (20) Modbus Meter Carlo Gavazzi EM200
  • (29) Modbus Meter Carlo Gavazzi EM210
  • (21) Modbus Meter Carlo Gavazzi EM340
  • (37) Modbus DZG DVH4013
  • (7) Modbus Meter Eastron SDM630
  • (58) Modbus Eastron SDM230
  • (8) Modbus Eastron SDM120_220
  • (39) Modbus Eastron SDM72D
  • (68) Modbus Eastron SDM72D-M-V2
  • (32) Modbus ECS M3PRO
  • (13) Modbus Meter Finder
  • (12) Modbus Meter Garo EM270
  • (10) Modbus Meter Garo GNM1D
  • (9) Modbus Meter Garo GNM3D
  • (22) Modbus Meter Garo GNM3T
  • (28) Modbus Meter Garo GNM3TD
  • (11) Modbus Meter Garo GM3T
  • (80) Modbus Meter Garo GMI3D-LP
  • (38) Modbus Gossen Metrawatt EM2289
  • (27) Modbus Hager ECR380D
  • (23) Modbus IME CE4DMID31
  • (87) Modbus IME CE4DF3DTMID
  • (15) Modbus Inepro PRO1_2
  • (16) Modbus Inepro PRO380
  • (84) Modbus Wago 879-3000
  • (40) Modbus Iskra WM3M6
  • (78) Modbus Iskra IE38M
  • (79) Modbus Meter Finder 7M38
  • (33) Modbus Janitza UMG 512/96 PRO
  • (35) Modbus Janitza UMG 605 PRO
  • (64) Modbus NZR EcoCount S85/SL85
  • (17) Modbus Optec
  • (45) Modbus Phoenix Contact EEM-EM357
  • (14) Modbus Saia ALE3
  • (82) Modbus Schneider Generic
  • (31) Modbus Schneider iEM3555
  • (24) Modbus Siemens 7KT1666
  • (49) Modbus YTL DTS353F
  • (50) EV Optimizer
  • (53) Modbus SELEC EM2M-1P-C-100A
  • (55) Modbus Lovato DMED 301
  • (56) Modbus Eetarp GEM630
  • (57) Modbus Eetarp GEM230
  • (65) Modbus DZG DWH4113
  • (66) Modbus ABB D1M
  • (60) ER Eastron SDM630-EV
  • (61) ER NZR EcoCount SL+SC 85
  • (63) ER NZR EcoCount SL+S 85
  • (62) ER Iskra WM3M4C
  • (69) ER EMH iML
  • (1) S0 Meter 'Opto 1 In'
  • (72) Modbus Eichrecht
  • (3) No Meter
  • Default: No Meter
Vendor
#
OCPPMode
OCPPMode_custom
This parameter determines whether backend communication is done using the standard OCPP JSON variant
Master
Config UI + OCPP
Yes
Read-write
  • (0) OCPP-J 1.6
  • (2) OCPP-B 1.5
  • (3) OCPP-B 1.6
  • Default: OCPP-J 1.6
Vendor
#
OCPPSchuko
OCPPSchuko_custom
Use auxiliary input/output to support additional Schuko Socket
Not relevant
Config UI + OCPP
Yes
Read-only
  • (0) Disable
  • (1) Enable 'Opto 1 In'
  • Default: Disable
Vendor
#
OCPPViaLocalNetwork
OCPPViaLocalNetwork_custom
If 'On' is selected, the minimum value of parameter 'Meter Value Sample Interval (OCPP)' is reduced
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
OPKGInstallExtraOption
OPKGInstallExtraOption_custom
Both
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
OcppCertificate
OcppCertificate_custom
Certificate used for SSL connections to the backend.
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
OcppConStrictTls
OcppConStrictTls_custom
If 'All ciphers' is selected, all recent TLS versions will be accepted. For 'Only secure ciphers' an
Master
Config UI + OCPP
Yes
Read-write
  • (0) All ciphers
  • (1) Only secure ciphers
  • Default: All ciphers
Vendor
#
OcppGetConfBoolIsInt
OcppGetConfBoolIsInt_custom
If activated, boolean OCPP keys are returned as integer values '0' or '1' in command 'GetConfigurati
Both
Config UI + OCPP
No
Read-write
[0..1] Default: Off
Vendor
#
OcppMeterCurrent
OcppMeterCurrent_custom
Phases Current in Ampere measured by OCPP meter.
Individual
Config UI + OCPP
No
Read-only
Default: "Not available"
Vendor
#
OcppMeterEnergy
OcppMeterEnergy_custom
Computed energy consumption in Wh.
Individual
Config UI + OCPP
No
Read-only
Default: "Not available"
Vendor
#
OcppMeterPower
OcppMeterPower_custom
Computed power consumption in Watt from OCPP meter.
Individual
Config UI + OCPP
No
Read-only
Default: "Not available"
Vendor
#
OcppMeterVoltage
OcppMeterVoltage_custom
Phases Voltage in Volts measured by OCPP meter.
Individual
Config UI + OCPP
No
Read-only
Default: "Not available"
Vendor
#
OcppQueueFullAsErrorState
OcppQueueFullAsErrorState_custom
When set, a full OCPP message queue will cause an error state. Charging will be terminated.
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
OcppUserCaCertificate
OcppUserCaCertificate_custom
User CA Certificate (OCPP).
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
OperatorCurrentLimit
OperatorCurrentLimit_custom
Maximum current (in Amperes) that can be signaled to the vehicle for charging. If the parameter 'Ins
Individual
Config UI + OCPP
No
Read-write
[0..80] Default: 16
Vendor
#
OperatorSelectionMode
OperatorSelectionMode_custom
Operator Selection Mode, Auto or Manual...
Master
Config UI + OCPP
No
Read-only
  • (0) Automatic
  • (1) Manual
  • (2) Deregister from network
  • (3) Set Only
  • (4) Manual/Automatic
  • (5) Not Available
  • Default: Not Available
Vendor
#
P15118ConStrictTls
P15118ConStrictTls_custom
If 'Standard' is selected, any 15118 connection will be forced to connect only via TLS 1.2 or higher
Master
Config UI + OCPP
Yes
Read-write
  • (0) All ciphers
  • (1) Standard
  • Default: Standard
Vendor
#
P15118EVSlacReqTimeout
P15118EVSlacReqTimeout_custom
This time indicates how long the EVSE should signal 5% to wait for EV SLAC requests. When this timeo
Both
Config UI + OCPP
Yes
Read-write
[1..50] Default: 7
Vendor
#
PDL_Power
PDL_Power_custom
PDL Power
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
PatternOnRelayK2
PatternOnRelayK2_custom
Behavior for the relay 2 (K2), to be used for an external indicator light such as an LED or blinking
Not relevant
Config UI + OCPP
No
Read-only
  • (0) Disable
  • (1) On while charging
  • (2) Off while charging
  • (4) Off while vehicle connected
  • (5) Blink pattern 1
  • (6) On while Inoperative
  • (7) On while Authorized
  • (8) On while Faulted
  • Default: Disable
Vendor
#
PauseChargingStateD
PauseChargingStateD_custom
If set to On, charging transactions are paused in case State D is detected. While state D is detecte
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
PhasesConnected
PhasesConnected_custom
Shows how the number of phases connected to the ChargePoint is configured.
Individual
Config UI + OCPP
No
Read-only
Default: "Three-phase system"
Vendor
#
PortBinaryOCPP
PortBinaryOCPP_custom
TCP port of the proxy server for binary OCPP communication with the backend.
Master
Config UI + OCPP
Yes
Read-write
[1..65535] Default: 444
Vendor
#
PowerLineVoltage
PowerLineVoltage_custom
Single phase RMS voltage of the power source feeding the ChargePoint in Volts. This is used for curr
Individual
Config UI + OCPP
Yes
Read-write
[186..274] Default: 230
Vendor
#
RCDAUTORECLOSURE
RCDAUTORECLOSURE_custom
Allows to enable the automatic reclosure of the RCD. The auxiliary relay output (on CC612: C3/4, on
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
RCDAUTORECLOSUREATTEMPTS
RCDAUTORECLOSUREATTEMPTS_custom
RCD auto reclosure attempts.
Both
Config UI + OCPP
Yes
Read-write
[1..10] Default: 3
Vendor
#
RCDAUTORECLOSUREDELAY
RCDAUTORECLOSUREDELAY_custom
RCD auto reclosure delay in seconds.
Both
Config UI + OCPP
Yes
Read-write
[30..1800] Default: 900
Vendor
#
RCDENABLE
RCDENABLE_custom
Allows to enable RCD detection. It must be Off when there is no RCD connected to the controller. If
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) Opto input
  • Default: Off
Vendor
#
RCDRESET
RCDRESET_custom
RCD Reset
Individual
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
RCMBDelta
RCMBDelta_custom
Minimum residual current change (in tenth of a milliamp) for which an OCPP status notification is se
Both
Config UI + OCPP
No
Read-write
[0..999] Default: 0
Vendor
#
RCMBIEC62955Mode
RCMBIEC62955Mode_custom
Configures the RCMB to comply with IEC62955 or IEC62752. Important note: If set to 'IEC62955 (locked
Individual
Config UI + OCPP
Yes
Read-only
  • (0) IEC 62752
  • (1) IEC 62955
  • Default: IEC 62955
Vendor
#
RCMBTransactionMaxDC
RCMBTransactionMaxDC_custom
Largest DC value measured while a transaction was in progress
Individual
Config UI + OCPP
No
Read-only
Default: " 0.0"
Vendor
#
RCMBTransactionMaxRMS
RCMBTransactionMaxRMS_custom
Largest RMS value measured while a transaction was in progress
Individual
Config UI + OCPP
No
Read-only
Default: " 0.0"
Vendor
#
RCMBVersion
RCMBVersion_custom
Version of the RCMB module connected to the ChargePoint.
Individual
Config UI + OCPP
No
Read-only
Default: "D0660, V2.01"
Vendor
#
RCMB_STATE
RCMB_STATE_custom
RDC-M (RCMB) protection state; Maximum values of last transaction; Current values
Individual
Config UI + OCPP
No
Read-only
Default: "DC: OK, RDC-M (RCMB) Device Status (IEC 62955): OK Last transactio..."
Vendor
#
RFIDEnable
RFIDEnable_custom
Enables or disables the RFID reader. Allows preventing error messages if no reader is installed.
Individual
Config UI + OCPP
No
Read-only
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
RSSI
RSSI_custom
Received Signal Strength Indicator as reported by the modem. This parameter is an indication how wel
Master
Config UI + OCPP
No
Read-only
Default: "0 (Extremely low)"
Vendor
#
RandomRestartAfterPowerLoss
RandomRestartAfterPowerLoss_custom
If this feature is enabled, the restart of charging will be randomized after a power loss. In case o
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
ReducedCurrent
ReducedCurrent_custom
Charging current value in Ampere when temperature is above temperature threshold 1.
Individual
Config UI + OCPP
No
Read-only
[6..80] Default: 16
Vendor
#
ReducedCurrentPct
ReducedCurrentPct_custom
How much (in %) of signaled current should be applied to reduce temperature when temperature is abov
Individual
Config UI + OCPP
No
Read-only
[0..100] Default: 100
Vendor
#
RegenerateOcppCertAndKey
RegenerateOcppCertAndKey_custom
Trigger Regeneration of Private Key and Self Signed Certificate for OCPP.
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
Req3GNetworkOperator
Req3GNetworkOperator_custom
The name of the network operator to be used in manual 'Network selection mode'.
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
ReserveConnectorZeroSupported
ReserveConnectorZeroSupported_custom
If set to 'On' the ChargePoint supports reservations on connector 0.
Master
Config UI + OCPP
No
Read-only
[0..1] Default: Off
Standard
#
ResetRetries
ResetRetries_custom
Number of times to retry an unsuccessful reset of the ChargePoint.
Individual
Config UI + OCPP
Yes
Read-write
[0..100] Default: 100
Standard
#
RestInterfaceEnable
RestInterfaceEnable_custom
This option enables the REST interface. It provides the status of the charge controller, error messa
Both
Config UI + OCPP
Yes
Read-write
(0) Disabled (1) Enabled (with UID) (2) Enabled (without UID) Default: Disabled
Vendor
#
RestartTransAfterPowerLoss
RestartTransAfterPowerLoss_custom
Enable if a transaction that was interrupted by a power loss shall be continued once the power is re
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
RetransmitMeterValues
RetransmitMeterValues_custom
If enabled, MeterValue messages are retransmitted on errors.
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
RfidTagFreeCharging
RfidTagFreeCharging_custom
RFID Tag for Free Charging with OCPP Full, fixed RFID modes. Note that this RFID Tag is also used wh
Individual
Config UI + OCPP
Yes
Read-write
Default: "freecharging"
Vendor
#
SIMPIN
SIMPIN_custom
PIN number that should be used to unlock the SIM card. This number is only used if the SIM card requ
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
SMAChargeCompleteTime
SMAChargeCompleteTime_custom
This value configures the time of day until the charging process should be completed. At least the m
Master
Config UI + OCPP
No
Read-write
Default: "08:00"
Vendor
#
SMAChargingMode
SMAChargingMode_custom
This option sets the directly applicable charging mode. In surplus charging mode, the vehicle charge
Master
Config UI + OCPP
No
Read-write
  • (0) Manual configuration
  • (1) Immediate charging
  • (2) Surplus charging
  • Default: Manual configuration
Vendor
#
SMACommunicationTimeout
SMACommunicationTimeout_custom
If the charging station cannot reach the energy manager for longer than set, the connection is consi
Master
Config UI + OCPP
No
Read-write
[60..3600] Default: 600
Vendor
#
SMACommunicationTimeoutCurrent
SMACommunicationTimeoutCurrent_custom
If the connection to the energy manager fails, the charging current is set to the value set here. Se
Master
Config UI + OCPP
No
Read-write
[6..80] Default: 6
Vendor
#
SMAInterfaceOnOff
SMAInterfaceOnOff_custom
The charging station can be networked with the SMA Sunny Home Manager 2.0 to charge primarily or exc
Master
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
SMAMaxEnergyDemand
SMAMaxEnergyDemand_custom
This value sets the maximum energy demand that is reported to the Energy Manager for the charging po
Master
Config UI + OCPP
No
Read-write
[1..1000] Default: 30
Vendor
#
SMAMinEnergyDemand
SMAMinEnergyDemand_custom
This value sets the minimum amount of energy that is reported to the Energy Manager for the charge p
Master
Config UI + OCPP
No
Read-write
[0..1000] Default: 5
Vendor
#
SPDCFG
SPDCFG_custom
Allows support for Surge Protection Devices (SPD). It must be 'Off' when there is no SPD connected t
Individual
Config UI + OCPP
Yes
Read-write
(0) Off (1) On OPTO C6/5 (Normally closed) (2) On OPTO C6/5 (Normally open) Default: Off
Vendor
#
SSHAccessEth
SSHAccessEth_custom
Disables SSH access to the controller via Ethernet.
Individual
Config UI + OCPP
Yes
Read-only
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
SSHAccessGsm
SSHAccessGsm_custom
Disables SSH access to the controller via GSM.
Individual
Config UI + OCPP
Yes
Read-only
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
SSHAccessUsb
SSHAccessUsb_custom
Disables SSH access to the controller via USB.
Individual
Config UI + OCPP
Yes
Read-only
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
SSHAccessWlanNetwork
SSHAccessWlanNetwork_custom
Disables SSH access to the controller via WLAN.
Individual
Config UI + OCPP
Yes
Read-only
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
SSHClientKey
SSHClientKey_custom
Key for authorizing the user 'root' of the ChargePoint to connect to server via SSH. This authorizat
Master
Config UI + OCPP
No
Read-only
Default: "ssh-rsa AAAAB3NzaC1yc2EAAAADAQABAAABAQCNqOyR/bAsG3s/rcj1ub+Zbeyds7DEP..."
Vendor
#
SSLModeClient
SSLModeClient_custom
Allows to set how strict SSL authentication is, from no authentication (encryption only) to full aut
Master
Config UI + OCPP
Yes
Read-write
  • (0) Normal SSL Auth
  • (1) Allow expired certificate
  • (2) Skip host check
  • (3) Allow expired certificate and skip host check
  • (4) Encrypt only - No authentication
  • Default: Encrypt only - No authentication
Vendor
#
ScanNetworkOperators
ScanNetworkOperators_custom
Determines whether a search for available network operators is carried out upon boot. Set the 'Scan
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
SeccCertExpireDate15118
SeccCertExpireDate15118_custom
Supply Equipment Charge Controller Certificate expiry date. This is the expiry date of the certifica
Individual
Config UI + OCPP
No
Read-only
Default: "Not Available"
Vendor
#
SeccLeafSubjectCommonName
SeccLeafSubjectCommonName_custom
Common Name of the SECC leaf certificate(s). It must be a SECCID.
Both
Config UI + OCPP
No
Read-write
Default: "DE-EBE-S-CHANGEME0000000000000000000000000000001"
Vendor
#
SeccLeafSubjectCountry
SeccLeafSubjectCountry_custom
Country of the SECC (EVSE) leaf certificate. Indicates in which country the CPO operates. Example: D
Both
Config UI + OCPP
No
Read-write
Default: "DE"
Vendor
#
SeccLeafSubjectOrganization
SeccLeafSubjectOrganization_custom
Organization of the SECC (EVSE) leaf certificate. Indicates which CPO operates this EVSE. Example: H
Both
Config UI + OCPP
No
Read-write
Default: "Bender GmbH Co. KG"
Vendor
#
SecondMeterIPAddress
SecondMeterIPAddress_custom
Sets the IP address of the second meter.
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
SecondMeterTCPPortNumber
SecondMeterTCPPortNumber_custom
Specifies the TCP port of the second meter.
Master
Config UI + OCPP
Yes
Read-write
[0..65535] Default: 502
Vendor
#
SecondMeterType
SecondMeterType_custom
Energy Management: the type of second meter used only for input to manage the current on the grid. F
Master
Config UI + OCPP
Yes
Read-write
  • (77) WiMOD IR Reader USB stick
  • (6) Modbus Meter ABB
  • (47) Modbus ABB EV3
  • (44) Modbus Berg B23
  • (43) Modbus Berg BME 461
  • (19) Modbus TQ EM300-LR
  • (41) Modbus TQ EM410/EM420
  • (86) Modbus Meter Carlo Gavazzi EM111/112
  • (20) Modbus Meter Carlo Gavazzi EM200
  • (29) Modbus Meter Carlo Gavazzi EM210
  • (21) Modbus Meter Carlo Gavazzi EM340
  • (7) Modbus Meter Eastron SDM630
  • (58) Modbus Eastron SDM230
  • (8) Modbus Eastron SDM120_220
  • (39) Modbus Eastron SDM72D
  • (68) Modbus Eastron SDM72D-M-V2
  • (32) Modbus ECS M3PRO
  • (13) Modbus Meter Finder
  • (12) Modbus Meter Garo EM270
  • (10) Modbus Meter Garo GNM1D
  • (9) Modbus Meter Garo GNM3D
  • (22) Modbus Meter Garo GNM3T
  • (28) Modbus Meter Garo GNM3TD
  • (11) Modbus Meter Garo GM3T
  • (80) Modbus Meter Garo GMI3D-LP
  • (27) Modbus Hager ECR380D
  • (23) Modbus IME CE4DMID31
  • (87) Modbus IME CE4DF3DTMID
  • (15) Modbus Inepro PRO1_2
  • (16) Modbus Inepro PRO380
  • (84) Modbus Wago 879-3000
  • (40) Modbus Iskra WM3M6
  • (78) Modbus Iskra IE38M
  • (79) Modbus Meter Finder 7M38
  • (33) Modbus Janitza UMG 512/96 PRO
  • (35) Modbus Janitza UMG 605 PRO
  • (64) Modbus NZR EcoCount S85/SL85
  • (17) Modbus Optec
  • (45) Modbus Phoenix Contact EEM-EM357
  • (14) Modbus Saia ALE3
  • (82) Modbus Schneider Generic
  • (31) Modbus Schneider iEM3555
  • (24) Modbus Siemens 7KT1666
  • (49) Modbus YTL DTS353F
  • (51) Modbus Sunspec Meter
  • (50) EV Optimizer
  • (53) Modbus SELEC EM2M-1P-C-100A
  • (55) Modbus Lovato DMED 301
  • (56) Modbus Eetarp GEM630
  • (57) Modbus Eetarp GEM230
  • (59) Modbus Temco Controls SPM1-XX0-AC
  • (66) Modbus ABB D1M
  • (1) S0 Meter 'Opto 1 In'
  • (3) No Meter
  • Default: No Meter
Vendor
#
SendLocalListMaxLength
SendLocalListMaxLength_custom
Maximum number of identifications that can be send in a single SendLocalList.req
Master
Config UI + OCPP
No
Read-write
[0..45000] Default: 45000
Standard
#
SetCountContactorCyclesType2UnderLoad
SetCountContactorCyclesType2UnderLoad_custom
Use this field when the contactor under load is replaced and the counter for contactor cycles must b
Individual
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
SetType2PlugCycles
SetType2PlugCycles_custom
Use this field when the type2 socket is replaced and the counter for socket cycles must be reset to
Individual
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
SetTypeContactorCycles
SetTypeContactorCycles_custom
Use this field when the contactor is replaced and the counter for contactor cycles must be reset to
Individual
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
SignaledCurrentLimit
SignaledCurrentLimit_custom
Current (in Ampere) that is signaled to the vehicle via PWM.
Individual
Config UI + OCPP
No
Read-only
Default: "0 A"
Vendor
#
SignedUpdates
SignedUpdates_custom
Enables or disables the signature verification for software updates.
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
SmartChargingDisconnectedLimit
SmartChargingDisconnectedLimit_custom
Disconnected Upper Limit applied to SmartCharging in case the ChargePoint is disconnected from the b
Individual
Config UI + OCPP
Yes
Read-write
[0..999] Default: 16
Vendor
#
SmartChargingUseDisconnectedLimit
SmartChargingUseDisconnectedLimit_custom
If enabled and the ChargePoint gets disconnected from the Backend, the 'Disconnected Upper Limit [A]
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Standard
#
SocketType2State
SocketType2State_custom
State of TYPE2 socket at connector 1.
Individual
Config UI + OCPP
No
Read-only
Default: "(A) Vehicle not connected Cable attached AMCC: (-/-/-)"
Vendor
#
StaticNetworkConfigAddress
StaticNetworkConfigAddress_custom
Static LAN IP of the ChargePoint.
Master
Config UI + OCPP
Yes
Read-write
Default: "192.168.0.100"
Vendor
#
StaticNetworkConfigDNS
StaticNetworkConfigDNS_custom
DNS server to use for the LAN of the ChargePoint.
Master
Config UI + OCPP
Yes
Read-write
Default: "8.8.8.8"
Vendor
#
StaticNetworkConfigGateway
StaticNetworkConfigGateway_custom
Gateway to use for the LAN of the ChargePoint.
Master
Config UI + OCPP
Yes
Read-write
Default: "192.168.0.1"
Vendor
#
StaticNetworkConfigNetmask
StaticNetworkConfigNetmask_custom
Netmask to use for the LAN of the ChargePoint.
Master
Config UI + OCPP
Yes
Read-write
Default: "255.255.255.0"
Vendor
#
StatusNotificationStrategy
StatusNotificationStrategy_custom
This parameter determines on which conditions the ChargePoint changes into the OCCUPIED state. In 'O
Both
Config UI + OCPP
Yes
Read-write
  • (0) Occupied on Authorized/Plugged
  • (1) Occupied on Charging
  • Default: Occupied on Charging
Vendor
#
StatusNotificationWebuiLogin
StatusNotificationWebuiLogin_custom
Status notification will be sent to backend in case of login success/failure for webui.
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
StopTransactionModeUnplug
StopTransactionModeUnplug_custom
This allows to modify the behavior of the charger at the end of a transaction. Normal unlocks and st
Both
Config UI + OCPP
Yes
Read-write
  • (0) Normal
  • (1) Stop only by unplugging
  • (2) Unlock only by RFID/RemoteStop
  • (3) Normal + Mode D
  • Default: Normal
Vendor
#
StopTransactionOnEVSideDisconnect
StopTransactionOnEVSideDisconnect_custom
When set to 'On' the Charge Point will stop a transaction when the cable is unplugged from the EV.
Both
Config UI + OCPP
No
Read-only
[0..1] Default: On
Standard
#
StopTransactionOnInvalidId
StopTransactionOnInvalidId_custom
Determines if the ChargePoint will stop an ongoing transaction when it receives a non-Accepted autho
Individual
Config UI + OCPP
No
Read-write
[0..1] Default: On
Standard
#
StopTxnAlignedData
StopTxnAlignedData_custom
Not supported (included for compatibility).
Both
Config UI + OCPP
No
Read-write
Default: ""
Standard
#
StopTxnSampledData
StopTxnSampledData_custom
Not supported (included for compatibility).
Both
Config UI + OCPP
No
Read-write
Default: ""
Standard
#
SupportedFeatureProfiles
SupportedFeatureProfiles_custom
List of supported Feature Profiles. Possible profile identifiers: Core, FirmwareManagement, LocalAut
Master
Config UI + OCPP
No
Read-only
Default: "Core,FirmwareManagement,LocalAuthListManagement,Reservation,SmartChar..."
Standard
#
SupportedFileTransferProtocols
SupportedFileTransferProtocols_custom
List of supported file transfer protocols: FTP, FTPS, SCP, HTTP and HTTPS
Master
Config UI + OCPP
No
Read-only
Default: "FTP, FTPS, SCP, HTTP, HTTPS"
Standard
#
TamperDetectionInputEnable
TamperDetectionInputEnable_custom
When enabled, the individual charge controller informs the backend with a status notification that t
Individual
Config UI + OCPP
Yes
Read-only
(0) Off (1) On Opto1 In (Normally closed) (2) On Opto1 In (Normally open) Default: Off
Vendor
#
TcpWatchdogTimeout
TcpWatchdogTimeout_custom
This is the time in seconds in which the connection to the backend can be not working until the syst
Individual
Config UI + OCPP
Yes
Read-write
[0..100000] Default: 10800
Vendor
#
Tcpdump
Tcpdump_custom
Switch 'tcpdump' on or off for dumping packets data at the configured interface into the log file 'p
Individual
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
TcpdumpInterface
TcpdumpInterface_custom
The type of interface we want to dump packet data into file. Choose 'Any' to listen on any network i
Individual
Config UI + OCPP
No
Read-write
  • (1) Backend Host
  • (0) Any
  • (3) GSM
  • (2) Ethernet
  • (4) USB
  • (5) WLAN
  • Default: Any
Vendor
#
TempDelta
TempDelta_custom
Temperature change in degrees Celsius for which a new temperature measurement report is sent to the
Master
Config UI + OCPP
No
Read-only
[0..50] Default: 5
Vendor
#
TempReduceThreshold1
TempReduceThreshold1_custom
Temperature threshold necessary to start decreasing the current.
Individual
Config UI + OCPP
No
Read-only
[40..100] Default: 85
Vendor
#
TempStopThreshold2
TempStopThreshold2_custom
Temperature threshold necessary to stop charging.
Individual
Config UI + OCPP
No
Read-only
[40..100] Default: 85
Vendor
#
ThresholdContactorCurrentUnderLoad
ThresholdContactorCurrentUnderLoad_custom
Set threshold contactor current under load (in Amperes)
Individual
Config UI + OCPP
Yes
Read-only
[6..80] Default: 6
Vendor
#
TransactionMessageAttempts
TransactionMessageAttempts_custom
Sets how often the ChargePoint tries to submit a transaction-related message when the backend fails
Individual
Config UI + OCPP
Yes
Read-write
[0..5] Default: 5
Standard
#
TransactionMessageRetryInterval
TransactionMessageRetryInterval_custom
Sets how long the ChargePoint will wait before resubmitting a transaction-related message that the b
Individual
Config UI + OCPP
Yes
Read-write
[0..1000] Default: 0
Standard
#
Type2ContactorLifetime
Type2ContactorLifetime_custom
Maximum number of operating cycles the contactor should be allowed to perform until a replacement is
Individual
Config UI + OCPP
Yes
Read-only
[0..100000000] Default: 10000000
Vendor
#
Type2PlugCounter
Type2PlugCounter_custom
Number of times the plug of the type2 socket was plugged in.
Not relevant
Config UI + OCPP
No
Read-only
Default: "44/50,000"
Vendor
#
Type2PlugLifetime
Type2PlugLifetime_custom
The maximum number of times the plug of the type2 socket can be plugged in safely..
Individual
Config UI + OCPP
Yes
Read-only
[0..10000000] Default: 50000
Vendor
#
UPnPUUID
UPnPUUID_custom
The UPnP UUID that this ChargePoint uses when announcing its presence on the local network. Only use
Individual
Config UI + OCPP
Yes
Read-only
Default: "12b3074f-5f49-4368-b4d7-fe2ae0663b1c"
Vendor
#
USBConfigUpdate
USBConfigUpdate_custom
Allow update of the charge point configuration via USB stick.
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
USBFieldEngineer
USBFieldEngineer_custom
Allow getting diagnostics and configuration of the ChargePoint via USB stick.
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
USBFirmwareUpdate
USBFirmwareUpdate_custom
Allow update of the charge point firmware via USB stick.
Both
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
UnlockConnectorOnEVSideDisconnect
UnlockConnectorOnEVSideDisconnect_custom
When set to 'On' the Charge Point will unlock the cable on Charge Point side when the cable is unplu
Both
Config UI + OCPP
No
Read-only
[0..1] Default: On
Standard
#
UsbErrorStatusNotifications
UsbErrorStatusNotifications_custom
This parameter determines whether USB communication errors between master and slave are reported to
Individual
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
Used3GNetworkOperator
Used3GNetworkOperator_custom
Name of the network operator the built-in modem is currently connected to.
Master
Config UI + OCPP
No
Read-only
Default: ""
Vendor
#
UserInstallerPasswordCheck
UserInstallerPasswordCheck_custom
Master
Config UI + OCPP
No
Read-write
[0..4294967295] Default: 1
Vendor
#
VentHeatingCtrlMode
VentHeatingCtrlMode_custom
This parameter allows to enable the activation of an external fan or heater according to the housing
Both
Config UI + OCPP
Yes
Read-write
(0) Off (1) Status D (Ventilation Required by vehicle) (2) Charging (Ventilation) (3) Above thres...
Vendor
#
VentHeatingHyst
VentHeatingHyst_custom
This delta in degree (Celsius) allows to add hysteresis to the fan or heater control. In order to sw
Both
Config UI + OCPP
Yes
Read-only
[0..25] Default: 4
Vendor
#
VentHeatingTempThr
VentHeatingTempThr_custom
Temperature threshold necessary to start or stop the fan or heater.
Both
Config UI + OCPP
Yes
Read-only
[-40..100] Default: 85
Vendor
#
WANRouter
WANRouter_custom
Enables access from LAN interfaces to the selected WAN (GSM/Ethernet/WLAN) interface. This will also
Master
Config UI + OCPP
Yes
Read-write
  • (0) Off
  • (1) On
  • Default: Off
Vendor
#
WANRouterInterface
WANRouterInterface_custom
Selects the WAN (GSM/Ethernet/WLAN) interface.
Master
Config UI + OCPP
Yes
Read-write
(0) GSM Default: GSM
Vendor
#
WLANEnabled
WLANEnabled_custom
Enable or disable WLAN.
Master
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) On
  • Default: On
Vendor
#
WLANNetworkConfigDHCPDelay
WLANNetworkConfigDHCPDelay_custom
DHCP request delay (in seconds) between multiple requests .
Master
Config UI + OCPP
No
Read-write
[0..100000] Default: 10
Vendor
#
WLANNetworkConfigDHCPRetries
WLANNetworkConfigDHCPRetries_custom
Number of DHCP requests sent before giving up on the DHCP server.
Master
Config UI + OCPP
No
Read-write
[0..100000] Default: 10
Vendor
#
WLANNetworkConfigDHCPTimeout
WLANNetworkConfigDHCPTimeout_custom
DHCP request timeout in seconds.
Master
Config UI + OCPP
No
Read-write
[0..100000] Default: 10
Vendor
#
WLANNetworkConfigMode
WLANNetworkConfigMode_custom
Network configuration mode for the ChargePoint's WLAN connection. Set to 'Auto' to use DHCP to confi
Master
Config UI + OCPP
Yes
Read-write
(0) Auto (DHCP client) (1) Static Default: Auto (DHCP client)
Vendor
#
WLANPassword
WLANPassword_custom
Password of the WLAN the ChargePoint connectsto. The Chargepoint automatically chooses thecorrect en
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
WLANSSID
WLANSSID_custom
SSID of the WLAN the ChargePoint tries to connect to.
Master
Config UI + OCPP
No
Read-write
Default: ""
Vendor
#
WLANStaticNetworkConfigAddress
WLANStaticNetworkConfigAddress_custom
Static WLAN IP of the ChargePoint.
Master
Config UI + OCPP
Yes
Read-write
Default: "192.168.1.100"
Vendor
#
WLANStaticNetworkConfigDNS
WLANStaticNetworkConfigDNS_custom
DNS server to use for the WLAN of the ChargePoint.
Master
Config UI + OCPP
Yes
Read-write
Default: "8.8.8.8"
Vendor
#
WLANStaticNetworkConfigGateway
WLANStaticNetworkConfigGateway_custom
Gateway to use for the WLAN of the ChargePoint.
Master
Config UI + OCPP
Yes
Read-write
Default: "192.168.1.1"
Vendor
#
WLANStaticNetworkConfigNetmask
WLANStaticNetworkConfigNetmask_custom
Netmask to use for the WLAN of the ChargePoint.
Master
Config UI + OCPP
Yes
Read-write
Default: "255.255.255.0"
Vendor
#
WebSocketPingInterval
WebSocketPingInterval_custom
WebSockets keep-alive interval in seconds or 0 when unused. Using keep-alive on WebSockets layer is
Master
Config UI + OCPP
No
Read-write
[0..100000] Default: 0
Standard
#
WebsocketsProxyURL
WebsocketsProxyURL_custom
Specify the websockets proxy to connect to in the format HOST
, whereby PORT is optional and set
Master
Config UI + OCPP
Yes
Read-write
Default: ""
Vendor
#
WeldCheck
WeldCheck_custom
Welded contactor detection. For the '230V input' with and without PE check options (if available) L1
Individual
Config UI + OCPP
Yes
Read-only
  • (0) Disable
  • (1) Enabled 'Opto 1 In'
  • (3) Enable via weld check input 230V WITHOUT PE check
  • (4) Enable via weld check input 230V WITH PE check
  • Default: Disable
Vendor
#
WeldCheckAuxRelay
WeldCheckAuxRelay_custom
When enabled, the auxiliary relay will be activated whenever the contactor is welded. If enabled on
Both
Config UI + OCPP
No
Read-write
  • (0) Off
  • (1) Relais 13/14
  • Default: Off
Vendor
#
WeldCheckInType
WeldCheckInType_custom
Whether the welding detection input circuit is normally closed or normally open.
Individual
Config UI + OCPP
Yes
Read-only
  • (0) Normally open
  • (1) Normally closed
  • Default: Normally open
Vendor
#
WrittenOfferAddress
WrittenOfferAddress_custom
Configures the postal address part of the written offer that the user can write to in order to reque
Both
Config UI + OCPP
No
Read-only
Default: "Ebee Smart Technologies GmbH, Torgauer Str. 12-15 (Haus 4), 10829 Ber..."
Vendor
#
autochargeid
autochargeid_custom
This ID will be used for authorization in case the EV failed to communicate with the EVSE or does no
Both
Config UI + OCPP
Yes
Read-write
Default: "autochargeid"
Vendor
#
fll
fll_custom
Local whitelist of RFIDs independent of a backend connection.
Master
Config UI + OCPP
No
Read-write
Vendor
#
idTagLetterCase
idTagLetterCase_custom
Parameter that makes the RFID tag management configurable to upper or lower case.
Both
Config UI + OCPP
Yes
Read-write
Vendor
#
loglevel
loglevel_custom
Level for the logging system. For security reasons you may be asked to re-enter your credentials to
Both
Config UI + OCPP
No
Read-write
Vendor
#
loglevelcomponents
loglevelcomponents_custom
This parameter allows to set different log levels for different software components. The string ente
Both
Config UI + OCPP
No
Read-write
Default: ""
Vendor