OCPP error reference

OCPP StatusNotification error codes for Charge Controller, with activation and resolution messages and corrective actions

v6.2.2
Applies to
operatorsmanufacturers
UpdatedNov 10, 2026

OCPP error reference

This page lists the error messages the Charge Controller sends in OCPP StatusNotification requests, with the activation and resolution messages for each error and the corrective actions to take.

The error activation message is sent when an error occurs. The error resolution message, where defined, is sent when the error is cleared. Some errors clear automatically when an external condition returns to normal, for example when the temperature drops again. Others only clear after a reset, a power cycle, or replacement of a faulty part.

OCPP Error code⬍
Error activation message⬍
Error resolution message⬍
Transaction and charging is stopped⬍
Notes⬍
Corrective actions⬍
#
groundFailure
Residual current detected via sensor
Residual current situation resolved
Yes
Internal RCMB device (yellow coil). This detects also DC residual current.
The safety mechanism is reset to its original state every time the cable is unplugged from the chargepoint. Otherwise the error is automatically reset after a delay of 10 seconds if the EV was unplugged. In case the RCMB version is older than or equal to D0469, the delay is 15 minutes. If the problem persists, please check the yellow current transformer (coil) and its connection.
#
evCommunicationError
Vehicle signals error
Vehicle error resolved
No
Mode3 errors.
Disconnect EV and try again. If that doesn’t help, follow EV’s instructions.
#
evCommunicationError
Vehicle diode check failed - tamper detection
Vehicle with diode problem disconnected
Yes
Mode3 errors.
Disconnect EV and try again. If that doesn’t help, follow EV’s instructions.
#
overCurrentFailure
MCB of type 2 socket triggered
MCB type 2 reconnected
Yes
MCB needs to be re-armed, requires a maintenance visit.
#
overCurrentFailure
MCB of domestic socket triggered
MCB domestic socket reconnected
Yes
MCB needs to be re-armed, requires a maintenance visit.
#
groundFailure
RCD triggered
RCD reconnected
Yes
External RCD Device.
Up to a certain point this will be corrected automatically.
#
groundFailure
RCD may be triggered (OCPP meter power loss)
RCD may be reconnected (OCPP meter recovered)
Yes
External RCD Device.
Up to a certain point this will be corrected automatically.
#
otherError
Surge Protection Device (SPD) tripped. Replace.
Surge Protection Device (SPD) issue solved
No
External SPD Device.
Surge Protection Devices (SPD) needs to be replaced.
#
powerSwitchFailure
Contactor welded
Contactor weld resolved
Yes
Very likely requires a maintenance visit with high priority as it is an indication there might now be a not properly disconnected socket while no plug is inserted.
#
powerSwitchFailure
Phase relay welded or dropped
Phase relay weld or drop resolved
Yes
If still present after reboot may require a high priority maintenance visit, as it may be caused by a damaged power board.
#
powerSwitchFailure
Inconsistent phase configuration
Yes
Inconsistent phase configuration, e.g. system is configured to be connected to three phases, but a power board that can only be connected to a single phase is also configured. Please fix the configuration and reboot.
#
powerSwitchFailure
Phase relay can't be set for required config
Phase relays can again be set as required
Yes
If still present after reboot may require a high priority maintenance visit, as it may be caused by a damaged power board. As an intermediate solution for a system connected to three phases you may try to set this to a single phase.
#
connectorLockFailure
Plug locking failed
Plug locking failure solved
No
Typically caused by not fully inserted plugs, unplugging and attempting to plug again in most cases resolves the problem.
#
connectorLockFailure
Type 2 actuator stuck, cannot unlock
Type 2 locking actuator recovered
Yes
A mechanical problem may require a maintenance visit. An Unlock Connector or Hard Reset triggers another attempt to unlock.
#
connectorLockFailure
Could not detect type 2 locking actuator
Type 2 locking actuator detected
Yes
A mechanical problem may require a maintenance visit. A Hard Reset triggers another attempt to redetect the actuator type.
#
powerMeterFailure
OCPP meter not communicating
OCPP meter communication recovered
Yes
#
powerMeterFailure
External meter not communicating
External meter communication recovered
No
#
noError
Meter eichrecht not supported
Meter eichrecht supported
No
Meter eichrecht not supported, connecting the eichrecht meter is necessary for OCMF generation.
Check if meter supports eichrecht (public key should be displayed in state page).
#
otherError
EVSE and EV are incompatible
Incompatible EV disconnected
Yes
EVSE and EV are incompatible. The voltage, current or power values or transfer mode of the EV are not compatible with the ones from EVSE.
#
readerFailure
RFID reader not communicating
RFID reader recovered
No
#
highTemperature
Cannot read temperature sensor
Temp sensor recovered
No
#
highTemperature
Cannot read critical temperature sensor
Critical temp sensor recovered
Yes
#
otherError
Voltage drop on HMICP detected
Voltage drop on HMICP recovered
No
#
otherError
Light sensor on HMICP failure
Light sensor on HMICP failure solved
No
#
otherError
Temperature sensor on HMICP failure
Temperature sensor on HMICP failure solved
No
#
otherError
Proximity sensor on HMICP failure
Proximity sensor on HMICP failure solved
No
#
otherError
Communication with HMICP failed
Communication with HMICP failed solved
No
#
otherError
HMICP controller failed
HMICP controller failed solved
No
#
highTemperature
Housing temperature too high - charging paused
Housing temp. below critical - charging resumed
No
#
noError
Housing temp. approaching limit - current reduced
Housing temp. back to normal - current restored
No
#
noError
Temperature is too low - charging paused
Temp. above minimum threshold - charging resumed
No
Ambient temperature is below the configured minimum threshold defined by the Temperature Minimum Threshold parameter. Charging will be paused if an ongoing session exists.
Wait until ambient temperature rises into the configured chargeable range defined by the Temperature Minimum Threshold parameter. Charging will be automatically resumed if ongoing.
#
highTemperature
Relay temperature too high - charging paused
Relay temp. below critical - charging resumed
No
#
noError
Relay temp. approaching limit - current reduced
Relay temp. back to normal - current restored
No
#
otherError
Temperature reaches safety limit - emergency stop
Temperature below safety limit - resume
Yes
#
weakSignal
SignalWeak:0//Not Availa/0
SignalGood:0//Not Availa/0
No
Low RSSI limit is 12 and high limit is 14.
#
otherError
GSM SIM card is missing
GSM SIM card inserted
No
GSM SIM card is missing.
Insert a SIM card in the dedicated slot.
#
otherError
FW Update in progress
FW Update finished
Yes
FW update command issued while update is already in progress.
Try again after first command was processed. Otherwise carry out a hard reset.
#
otherError
FW/USB Update failure deleted
No
Firmware update failed.
Try again.
#
noError
USB communication errors.
USB communication working properly.
No
USB communication errors.
Wait until application recovers from this error.
#
otherError
The ChargePoint is tilted.
The ChargePoint no longer is tilted.
Yes
The ChargePoint has been tilted.
A physical inspection and maintenance is required at the chargepoint location.
#
otherError
Possible CP and PR wiring issue.
Possible CP and PR wiring issue is solved.
Yes
A car is detected but no cable is detected.
Check the wiring of CP and PR cables, they may be swapped or the plug may be broken.
#
otherError
PR disconnected while car is connected.
PR disconnection issue is solved.
Yes
The proximity cable is disconnected while the car is plugged
Check the plug and socket PR contact, it may be defect. Check the internal PR wiring of the charging station and the charging cable.
#
otherError
OCPP Master and Slave have different SW version.
OCPP Master and Slave have same SW version.
No
The master and slave have different SW versions.
Maybe the firmware update has failed or a manual update was performed incorrectly.Check what is the expected FW version and update firmware.
#
otherError
RCMB measurement out of range.
Yes
The current transformer on the Chargepoint has a defect if this condition persists.
Replace the current transformer on the ChargePoint.
#
otherError
Car current is higher than expected.
Car is charging at nominal current.
No
The car is charging with 10% more than expected according to the signaled current. The charge point will try to solve it by decreasing the signaled current
Check the car.
#
otherError
Car current overload, charging stopped.
Car is charging at nominal current again.
Yes
The car is charging with a too high current. Charging will be stopped
Check the car.
#
connectorLockFailure
Actuator unlocked while charging
Actuator unlocked while charging solved
Yes
For some reason the actuator was unplugged during charging.
Verify the actuator and actuator wiring
#
otherError
The chargepoint was previously tilted
Chargepoint tilted issue deleted
Yes
The chargepoint was previously tilted.
It is not allowed to charge until the charge point is rebooted.
#
otherError
The chargepoint was previously shocked
Chargepoint shocked issue deleted
Yes
The chargepoint was previously shocked.
It is not allowed to charge until the charge point is rebooted.
#
otherError
Not all DLM Slaves connected
All DLM Slaves are connected again
No
Some DLM slaves are disconnected from DLM master.
Reconnect the DLM slaves to the DLM master again.
#
otherError
DLM Slave disconnected and not charging
DLM Slave is connected again
No
The DLM slave is disconnected from DLM master and its DisconnectedLimit is set to zero.
Reconnect the DLM slave to the DLM master again or increase its DisconnectedLimit.
#
otherError
USB stick handling finished
Yes
USB stick is inserted and is being handled.
Wait until all operations have finished.
#
otherError
Phase rotation failure.
Phase rotation direction normal.
Yes
A different phase rotation dir. has been detected from the option selected in the configuration. Phases have either been incorrectly installed, or misconfigured.
Configuration has to be changed consistently according to detected phase rotation dir., or the phases have to be correctly installed. A physical inspection and maintenance may be required at the chargepoint location.
#
underVoltage
There is no power on mains.
Grid power restored.
Yes
No power on mains has been detected.
A physical inspection and maintenance is required at the chargepoint location.
#
otherError
No
A component or set of components failed to initialize correctly.
An inspection and maintenance is required for the chargepoint, issue probably has to be escalated to be handled by a support engineer.
#
otherError
State D detected, charging is paused
Car no longer in state D, charging is resumed
No
Charging is paused because state D is detected.
Check the reason why car goes to state D.
#
underVoltage
Low voltage detected, charging is paused
Normal voltage detected, charging is resumed
No
Charging is paused because low voltage is detected. Charging will resume one minute after the electric grid stabilizes
Wait until the electric grid stabilizes.
#
overVoltage
High voltage detected, charging is paused
Normal voltage detected, charging is resumed
No
Charging is paused because high voltage is detected. Charging will resume one minute after the electric grid stabilizes
Wait until the electric grid stabilizes.
#
otherError
Low frequency detected, charging is paused
Normal frequency detected, charging is resumed
No
Charging is paused because low frequency is detected. Charging will resume one minute after the electric grid stabilizes
Wait until the electric grid stabilizes.
#
overCurrentFailure
RCD-MCB triggered from unique input
RCD-MCB from unique input reconnected
Yes
RCD-MCB needs to be re-armed.
#
noError
USB stick handling: Finalized - Remove USB stick
USB stick removed
No
USB stick is still inserted while all previous operations completed successfully.
Remove the USB stick.
#
noError
USB stick handling failed - Remove USB stick
USB stick removed
No
USB stick is still inserted while there were errors with previous operations.
Remove the USB stick and retry.
#
noError
Socket type 2 plug lifetime exceeded
Type 2 plug lifetime issue solved
No
Socket type 2 plug should be replaced.
#
connectorLockFailure
Actuator emergency opener faulted
Actuator emergency opener failure solved
Yes
A mechanical problem may require a maintenance visit.
#
groundFailure
Ground check (PE) failed
Ground check (PE) failure solved
No
A wiring problem may require a maintenance visit.
#
underVoltage
L1 voltage is missing
L1 voltage is not missing (contactor opened)
No
L1 line is not energized when it should since the contactor is closed
Verify that the charger wiring is correctand that no RCD or MCB protection is active.
#
underVoltage
No
Error occurs if issued power line is either not connected or the varistor at this line is defective.
Check varistor fault or mains outage.
#
otherError
Message queue is full
Message queue works again
Yes
Error occurs when the parameter "OcppQueueFullAsErrorState" was set by the operator and the OCPP message queue is full and cannot store further items.
Check the connection to the OCPP backend.
#
otherError
Internal communication error
Internal communication error resolved
Yes
Unexpected internal SW communication error.
A system reboot is required.
#
otherError
OCPP meter failure
OCPP meter failure resolved
Yes
OCPP meter reported a failure in the power line supply.
Check the power lines voltage, frequency and current.
#
internalError
15118 module failure
15118 module failure resolved
No
15118 module failed to initialize.
Reboot the chargepoint or check for hardware issues.
#
internalError
QCA7000 initialization failure
QCA7000 initialization failure resolved
No
QCA7000 initialization failure.
Reboot the chargepoint or check for hardware issues.
#
weakSignal
eth interface had 0 link up-down sequences.
Too many eth link up-down sequences resolved
No
Ethernet interface is having frequent disconnection and connections.
Verify the LAN network settings and state.
#
noError
Socket type 2 contactor lifetime exceeded
Type 2 contactor lifetime exceeded issue solved
No
Socket type 2 contactor should be replaced.
#
evCommunicationError
Socket type 2 contactor or CP handling error
Type 2 contactor or CP handling error issue solved
No
If this issue recurs, escalate it to a support engineer for further investigation.
#
underVoltage
Contactor not closed
Contactor error solved
No
Contactor or main relay has failed to close or it opened during charging
Verify that the charger wiring is correctand that the relay is in good condition.
#
otherError
CP ADC calibration aborted. (Value out of range)
CP ADC calibration failure solved
No
CP ADC calibration was aborted due to an out of range ADC value.
The board might need an inspection by a technician.
#
otherError
WLAN SSID or PSK is incorrectly configured
WLAN SSID and PSK are now correctly configured
No
WLAN was enabled but the SSID or the PSK was wrong.
Verify that WLAN SSID and the PSK was set correctly.
#
otherError
Fan defect, ventilation could not be started
Fan ventilation functionality recovered
Yes
#
otherError
Error config parameter: (null)
Yes
At least one config parameter is wrong and the charge point will not operate as expected.
Correct a wrong config parameter and reboot the controller. More information about the error cause could be found in the log file.
#
noError
Threshold contactor cycles under load exceeded
Threshold contactor cycles exceeded solved
No
Socket type 2 contactor should be replaced.
#
otherError
Meter is 1-phase, but system setting is 3-phase.
Meter is 1-ph, but sys setting is 3-ph resolved.
No
Meter is 1-phase, but system is 3-phase.
Change the installation setting to 1-phase.
#
otherError
Max Energy on invalid ID limit reached
Transaction with max energy on invalid ID ended
No
Max Energy on invalid ID limit reached - charging paused.
#
otherError
HMICP Power Reset detected.
HMICP Power Reset resolved.
No
HMICP Power Reset detected.
Check power supply and reset HMICP.
#
otherError
HMICP Watchdog Reset detected.
HMICP Watchdog Reset resolved.
No
HMICP Watchdog Reset detected.
Check HMICP and reset if necessary.
#
otherError
HMICP External Reset detected.
HMICP External Reset resolved.
No
HMICP External Reset detected.
Check external reset source and HMICP.
#
internalError
Hardware initialization failed
Hardware initialization recovered
Yes
Hardware required for charging could not be initialized. Charging is blocked, but the charge point stays reachable for diagnostics and software updates.
Check the log file for the failing module, then reboot the controller. If the error persists, replace the faulty hardware.
#
noError
Authorization failed.
No
#
otherError
Firmware update failed.
No
Firmware update failed (internet connection?).
Retry or perform a manual update.
#
otherError
Stopped transaction after restart! Power Outage?
No
ChargePoint rebooted while a transaction (charging) was active. Transaction was implicitely terminated.
Restart the transaction.
#
otherError
Slave is unavailable (disconnected from Master).
No
A Slave disconnected from the master.
Replace cable, repair connection, and wait until slave reconnects to master.
#
otherError
Diagnostics failed.
No
Diagnostics failed (internet connection?).
Retry.
#
groundFailure
RCMB error.
No
#
evCommunicationError
15118 communication error (exi decoder)
No
15118 communication failed
#
evCommunicationError
15118 communication error (exi encoder)
No
15118 communication failed
#
evCommunicationError
15118 communication error (TLS cert)
No
15118 communication failed
#
evCommunicationError
15118 communication error (V2G session id)
No
15118 communication failed
#
evCommunicationError
15118 communication error (TCP)
No
15118 communication failed
#
otherError
15118 authorization failed
No
15118 authorization for PnC failed. The signature validation failed
Install a valid certificate in the car and the correct root CA in the chargepoint
#
otherError
15118 authentication failed
No
15118 authentication for PnC failed
Install a valid certificate in the car and the correct root CA in the chargepoint
#
otherError
15118 certificate installation failed
No
15118 Certificate Installation failed
Verify that car and backend are handling the certificates properly
#
noError
System not yet ready.
No
#
noError
negative power reading from meter(wiring problem?)
No
negative power reading from meter (wiring problem?)
re-check the connected wirings to meter