Metering

1. Meter settings

To ensure proper communication between the Charge Controller and connected Modbus or Modbus TCP meters, some baseline configuration must be made directly on the meters.

1.1. Standard settings (primary meter and Eichrecht)

Setting
Set on
Value
Notes
#
Slave ID
Charge Controller
1
Must be hard-set on the meter
#
Baud rate
Meter
9600
#
Parity
none
Exception: Use even parity when working with a Saia meter

1.2. DLM-specific settings (Secondary Meters)

Setting
Set on
Value
Notes
#
Slave ID
Charge Controller
2
Must match the meter’s hardware config
#
Modbus address in Config UI
Must match the hardware ID of the secondary meter. If both meters (primary and secondary) share an RTU bus, then their addresses must be different

1.3. Controller-Meter pairings (Double Charging Station)

Controller Type
Connects to Primary Meter
Connects to Secondary/DLM Meter
#
Master
(optional, Modbus or TCP)
#
Slave
tip

These rules apply to all compatible meters listed in this documentation, unless an exception is noted in the meter-specific info.

2. Supported meters

Support for the meters listed here has been implemented and can be chosen in the Config UI on the Charge Controller. To know how a meter is named in the Config UI, look at the Label in Config UI column.

List
Info
#
Supported Eichrecht meters (Germany & Austria)
Eichrecht-compliant meters. These can be used as general-purpose meters as well but are generally more expensive, hence they are not repeated in the "internal meters" list.
#
Supported internal meters
These meters are suitable for installation inside a Charging Station. Interfaces are as follows: Modbus RTU, RJ10 (SML), S0.
#
Supported DLM meters
These meters can be used in a DLM context.
#
Supported Solar DLM meters
A subset of the "DLM meters" which are suitable and tested for Solar DLM.

3. Supported Eichrecht meters (Germany & Austria)

The meters listed here can be set up to be Eichrecht-compliant, but can also be used as general-purpose meters.

Manufacturer
Model
Label in Config UI
Connection/Protocol
Cable loss factor
Duration-based invoicing
Supported from
Note
#
EMH
eHZ generation K
eHZ Meter
RJ10 / SML
Not possible
Not possible
4.40
Eichrecht with CC612 only
eHZB
eHZ-B Meter
RJ10 / SML
possible
possible
5.32.0
Price display for kwH and total price display for kwH.
#
Eastron
SDM 630 EV
ER Eastron SDM630-EV
Modbus RTU
Possible
Not possible
5.33.2
#
NZR
EcoCount SL+SC 85
ER NZR EcoCount SL+SC 85
Modbus RTU
Possible
Not possible
5.33.0
EcoCount SL+S 85
ER NZR EcoCount SL+S 85
Modbus RTU
Not possible
Not possible
5.33.0
#
ISKRA
WM3M4C
ER Iskra WM3M4C
Modbus RTU
Possible
Not possible
5.33.0
#
Gossen Metrawatt
EM2289
Meter Modbus
Modbus RTU
Possible
Possible
5.12.5
Customer-specifc meter type
#
DZG
DVH 4013
Meter Modbus
Modbus RTU
Possible
Possible
5.23.0
Eichrecht with CC612/CC613 only
DWH 4013
Meter Modbus
Modbus RTU
Possible
Possible
5.21.1
DWH 4113
Meter Modbus
Modbus RTU
Possible
Possible
5.23.0

4. Supported internal meters

Manufacturer
Model
Label in Config UI
Connection/Protocol
Supported from
Additional info
#
ABB
B23
Modbus Meter ABB
Modbus RTU
5.12.1
D1M
Modbus ABB D1M
Modbus RTU
5.33.0
EV3
Modbus ABB EV3
Modbus RTU
5.23.0
#
BERG
B23
Modbus Berg B23
Modbus RTU
5.33.3
BME 461
Modbus Berg BME 461
Modbus RTU
5.30.0
#
Carlo Gavazzi
EM111
Modbus Meter Carlo Gavazzi EM111/112
Modbus RTU
5.32.0
EM112
Modbus Meter Carlo Gavazzi EM111/112
Modbus RTU
5.32.0
EM200
Modbus Meter Carlo Gavazzi EM200
Modbus RTU
5.20.5
EM210
Modbus Meter Carlo Gavazzi EM210
Modbus RTU
5.23.0
EM340
Modbus Meter Carlo Gavazzi EM340
Modbus RTU
5.12.1
EM540
Modbus Meter Carlo Gavazzi EM540
Modbus RTU
5.34.0
#
DZG
DVH4013
Modbus DZG DVH4013
Modbus RTU
5.21.1
DWH4113
Modbus DZG DWH4113
Modbus RTU
5.33.1
#
Eastron
SDM 120
Modbus Eastron SDM120_220
Modbus RTU
5.23.0
SDM 220
Modbus Eastron SDM120_220
Modbus RTU
5.23.0
SDM 630
Modbus Meter Eastron SDM630
Modbus RTU
4.30
SDM72D-M
Modbus Eastron SDM72D
Modbus RTU
5.12.1
SDM72D-M v2
Modbus Eastron SDM72D-M-V2
Modbus RTU
5.33.2
#
ECS
M3PRO
Modbus ECS M3PRO
Modbus RTU
5.32.0
#
Eetarp
GEM230
Modbus Eetarp GEM230
Modbus RTU
5.33.0
GEM630
Modbus Eetarp GEM630
Modbus RTU
5.33.0
#
EMH
eHZ generation K
eHZ Meter
RJ10 / SML
4.40
Interface only present on CC612
eHZB
eHZ-B Meter
RJ10 / SML
5.33.0
#
Finder
7E.x8
Modbus Meter Finder
Modbus RTU
4.30
7M38
Modbus Meter Finder 7M38
Modbus RTU
5.30.0
#
Garo
EM270
Modbus Meter Garo EM270
Modbus RTU
4.30
GM3T
Modbus Meter Garo GM3T
Modbus RTU
4.30
GMI3D LP
Modbus Meter Garo GMI3D-LP
Modbus RTU
5.29.5
GNM1D
Modbus Meter Garo GNM1D
Modbus RTU
4.30
GNM3D
Modbus Meter Garo GNM3D
Modbus RTU
4.30
GNM3T
Modbus Meter Garo GNM3T
Modbus RTU
5.23.0
GNM3TD
Modbus Meter Garo GNM3TD
Modbus RTU
5.12.5
#
Gossen Metrawatt
EM2289
Meter Modbus
Modbus RTU
5.12.5
#
Hager
ECR380D
Modbus Hager ECR380D
Modbus RTU
5.12.5
#
IME
CE4DF3DTMID
Modbus IME CE4DF3DTMID
Modbus RTU
5.33.5
CE4DMID31
Modbus IME CE4DMID31
Modbus RTU
5.12.5
#
INEPRO
PRO1
Modbus Inepro PRO1_2
Modbus RTU
5.12.5
PRO2
Modbus Inepro PRO1_2
Modbus RTU
5.12.5
PRO380
Modbus Inepro PRO380
Modbus RTU
5.20.6
#
Iskra
IE38M
Modbus Iskra IE38M
Modbus RTU
5.20.8
WM3M6
Modbus Iskra WM3M6
Modbus RTU
5.12.5
#
Janitza
UMG 512PRO
Modbus Janitza UMG 512/96 PRO
Modbus RTU
5.12.5
UMG 605PRO
Modbus Janitza UMG 605 PRO
Modbus RTU
5.12.5
UMG 96PRO
Modbus Janitza UMG 512/96 PRO
Modbus RTU
5.23.0
#
Lovato
DMED 301
Modbus Lovato DMED 301
Modbus RTU
5.33.0
#
NZR
EcoCount S85
Modbus NZR EcoCount S85/SL85
Modbus RTU
5.12.1
EcoCount SL85
Modbus NZR EcoCount S85/SL85
Modbus RTU
5.12.7
#
OPTEC
Modbus Optec
Modbus RTU
4.30
#
Phoenix Contact
EEM EM357
Modbus Phoenix Contact EEM-EM357
Modbus RTU
5.29.4
#
Saia
ALE3
Modbus Saia ALE3
Modbus RTU
4.30
Set parity to even
#
Schneider Electric
iEM3555
Modbus Schneider iEM3555
Modbus RTU
5.22.1
Schneider Generic
Modbus Schneider Generic
Modbus RTU
5.33.1
Generic implementation for Schneider Electric meter
#
SELEC
EM2M-1P-C-100A
Modbus SELEC EM2M-1P-C-100A
Modbus RTU
5.32.0
#
Siemens
7KT1666
Modbus Siemens 7KT1666
Modbus RTU
5.12.1
#
TQ
EM300LR
Modbus TQ EM300-LR
Modbus RTU
5.23.0
EM410
Modbus TQ EM410/EM420
Modbus RTU
5.23.0
EM420
Modbus TQ EM410/EM420
Modbus RTU
5.23.0
#
WAGO
879 3000
Modbus Wago 879-3000
Modbus RTU
5.32.0
#
YTL
DTS353F
Modbus YTL DTS353F
Modbus RTU
5.32.0
#
Generic (S0 Meter)
Any model
S0 Meter Opto
S0 pulse meter
5.12.1
Default: 1000 pulses/kWh
Not recommended

5. Supported DLM meters

Manufacturer
Model
Label in Config UI
Connection/Protocol
Supported from
Additional info
#
ABB
B23
Modbus Meter ABB
Modbus RTU
5.12.1
D1M
Modbus ABB D1M
Modbus RTU
5.33.0
D1M
Modbus ABB D1M (TCP)
Ethernet Modbus TCP
5.23.0
EV3
Modbus ABB EV3
Modbus RTU
5.32.0
#
BERG
B23
Modbus Berg B23
Modbus RTU
5.33.0
BME 461
Modbus Berg BME 461
Modbus RTU
5.30.0
#
Carlo Gavazzi
EM111
Modbus Meter Carlo Gavazzi EM111/112
Modbus RTU
5.32.0
EM112
Modbus Meter Carlo Gavazzi EM111/112
Modbus RTU
5.32.0
EM200
Modbus Meter Carlo Gavazzi EM200
Modbus RTU
5.20.5
EM210
Modbus Meter Carlo Gavazzi EM210
Modbus RTU
5.23.0
EM340
Modbus Meter Carlo Gavazzi EM340
Modbus RTU
5.32.0
EM540
Modbus Meter Carlo Gavazzi EM540
Modbus RTU
5.34.0
#
DZG
DVH4013
Modbus DZG DVH4013
Modbus RTU
5.21.1
DWH4113
Modbus DZG DWH4113
Modbus RTU
5.33.1
#
Eastron
SDM 120
Modbus Eastron SDM120_220
Modbus RTU
5.23.0
SDM 220
Modbus Eastron SDM120_220
Modbus RTU
5.23.0
SDM 630
Modbus Meter Eastron SDM630
Modbus RTU
4.30
SDM 630-EV
ER Eastron SDM630-EV
Modbus RTU
5.12.1
SDM72D-M
Modbus Eastron SDM72D
Modbus RTU
5.12.1
SDM72D-M v2
Modbus Eastron SDM72D-M-V2
Modbus RTU
5.33.2
#
ECS
M3PRO
Modbus ECS M3PRO
Modbus RTU
5.32.0
M3PRO
Modbus ECS M3PRO (TCP)
Ethernet Modbus TCP
5.32.0
#
Eetarp
GEM230
Modbus Eetarp GEM230
Modbus RTU
5.33.0
GEM630
Modbus Eetarp GEM630
Modbus RTU
5.33.0
#
EMH
eHZ generation K
eHZ Meter
RJ10 / SML
4.30
Interface only present on CC612
eHZB
eHZ-B Meter
RJ10 / SML
5.33.0
#
Finder
7E.x8
Modbus Meter Finder
Modbus RTU
4.30
7M38
Modbus Meter Finder 7M38
Modbus RTU
5.30.0
#
Garo
EM270
Modbus Meter Garo EM270
Modbus RTU
4.30
GM3T
Modbus Meter Garo GM3T
Modbus RTU
4.30
GMI3D LP
Modbus Meter Garo GMI3D-LP
Modbus RTU
5.29.5
GNM1D
Modbus Meter Garo GNM1D
Modbus RTU
4.30
GNM3D
Modbus Meter Garo GNM3D
Modbus RTU
4.30
GNM3T
Modbus Meter Garo GNM3T
Modbus RTU
5.23.0
GNM3TD
Modbus Meter Garo GNM3TD
Modbus RTU
5.12.5
#
Gossen Metrawatt
EM2289
Meter Modbus
Modbus RTU
5.12.5
#
Hager
ECR380D
Modbus Hager ECR380D
Modbus RTU
5.12.5
#
IME
CE4DF3DTMID
Modbus IME CE4DF3DTMID
Modbus RTU
5.33.5
CE4DMID31
Modbus IME CE4DMID31
Modbus RTU
5.12.5
#
INEPRO
PRO1
Modbus Inepro PRO1_2
Modbus RTU
5.12.5
PRO2
Modbus Inepro PRO1_2
Modbus RTU
5.12.5
PRO380
Modbus Inepro PRO380
Modbus RTU
5.20.6
#
Iskra
IE38M
Modbus Iskra IE38M
Modbus RTU
5.20.8
WM3M4C
ER Iskra WM3M4C
Modbus RTU
5.12.5
WM3M4C expects L3 powered in single-phase operation. To allow for both 1ph and 3ph operation, the meter needs to be rotated 240deg before the meter and 120deg after. See the meter manual for more.
WM3M6
Modbus Iskra WM3M6
Modbus RTU
5.12.5
#
Janitza
UMG 512PRO
Modbus Janitza UMG 512/96 PRO
Modbus RTU
5.12.5
UMG 512PRO
Modbus Janitza UMG 512/96 PRO (TCP)
Ethernet Modbus TCP
5.12.5
UMG 604PRO
Modbus Janitza UMG 604 PRO (TCP)
Ethernet Modbus TCP
5.23.0
Default Modbus ID: 1
UMG 605PRO
Modbus Janitza UMG 605 PRO
Modbus RTU
5.12.5
UMG 605PRO
Modbus Janitza UMG 605 PRO (TCP)
Ethernet Modbus TCP
5.12.5
UMG 96PRO
Modbus Janitza UMG 512/96 PRO
Modbus RTU
5.23.0
UMG 96PRO
Modbus Janitza UMG 512/96 PRO (TCP)
Ethernet Modbus TCP
5.23.0
#
Lovato
DMED 301
Modbus Lovato DMED 301
Modbus RTU
5.33.0
#
Mennekes
EV OPTIMIZER
EV Optimizer
Ethernet Modbus TCP
#
NZR
EcoCount S85
Modbus NZR EcoCount S85/SL85
Modbus RTU
5.12.1
EcoCount SL+S 85
ER NZR EcoCount SL+S 85
Modbus RTU
5.12.7
EcoCount SL+SC 85
ER NZR EcoCount SL+SC 85
Modbus RTU
5.33.1
EcoCount SL85
Modbus NZR EcoCount S85/SL85
Modbus RTU
5.33.1
#
OPTEC
Modbus Optec
Modbus RTU
4.30
#
Phoenix Contact
EEM EM357
Modbus Phoenix Contact EEM-EM357
Modbus RTU
5.29.4
EMpro EEM MB371
Modbus Phoenix Contact EEM-MB371 (TCP)
Ethernet Modbus TCP
5.12.5
#
Saia
ALE3
Modbus Saia ALE3
Modbus RTU
4.30
Set parity to even
#
Schneider Electric
iEM3555
Modbus Schneider iEM3555
Modbus RTU
5.22.1
Schneider Generic
Modbus Schneider Generic
Modbus RTU
5.33.1
Generic implementation for Schneider Electric meter
Schneider Generic (TCP)
Modbus Schneider Generic (TCP)
Ethernet Modbus TCP
5.33.1
#
SELEC
EM2M-1P-C-100A
Modbus SELEC EM2M-1P-C-100A
Modbus RTU
5.32.0
#
Siemens
7KM2200
Modbus Siemens 7KM2200 (TCP)
Ethernet Modbus TCP
5.22.1
7KT1666
Modbus Siemens 7KT1666
Modbus RTU
5.12.1
#
SMA
Commercial Energy Meter
SMA Commercial Energy Meter (TCP)
Ethernet Modbus TCP
5.33.1
#
Temco Controls
SPM1-XX0-AC
Modbus Temco Controls SPM1-XX0-AC
Modbus RTU
5.33.1
#
TQ
EM300LR
Modbus TQ EM300-LR
Modbus RTU
5.23.0
EM410
Modbus TQ EM410/EM420
Modbus RTU
5.23.0
EM420
Modbus TQ EM410/EM420
Modbus RTU
5.23.0
EM300LR
Modbus TQ EM300-LR (TCP)
Ethernet Modbus TCP
5.23.0
EM410
Modbus TQ EM410/EM420 (TCP)
Ethernet Modbus TCP
5.23.0
EM420
Modbus TQ EM410/EM420 (TCP)
Ethernet Modbus TCP
5.23.0
#
WAGO
879 3000
Modbus Wago 879-3000
Modbus RTU
5.32.0
#
Walther Werke
IPD CONTROL
Modbus IPD Control (TCP)
Ethernet Modbus TCP
5.29.1
#
YTL
DTS353F
Modbus YTL DTS353F
Modbus RTU
5.32.0
#
WiMOD
IR Reader USB stick
WiMOD IR Reader USB stick
eHZ meter
Second meter only

6. Supported Solar DLM Meters

Manufacturer
Model
Description in constraint File
Connection/Protocol
Supported from
Additional info
#
Phoenix Contact
EMpro EEM MB371
Modbus Phoenix Contact EEM-MB371 (TCP)
Ethernet Modbus TCP
5.33.1
#
Siemens
Modbus Siemens 7KM2200 (TCP)
Modbus Siemens 7KM2200 (TCP)
Ethernet Modbus TCP
5.33.1
#
TQ
EM410
Modbus TQ EM410/EM420 (TCP)
Ethernet Modbus TCP
5.33.1
EM420
Modbus TQ EM410/EM420 (TCP)
Ethernet Modbus TCP
5.33.1
#
ABB
B23
Modbus Meter ABB
Modbus RTU
5.33.3
info

This list applies to SDLM when the Configure Solar Mode for DLM setting is set to Grid Charging.
Otherwise if the setting is set to any other mode, any supported meter can be used.