Metering

1. Meter settings

To ensure proper communication between the Charge Controller and connected Modbus or Modbus TCP meters, some baseline configuration must be made directly on the meters.

1.1. Standard settings (primary meter and Eichrecht)

SettingSet onValueNotes
Slave IDCharge Controller1Must be hard-set on the meter
Baud rateMeter9600
ParitynoneException: Use even parity when working with a Saia meter

1.2. DLM-specific settings (Secondary Meters)

SettingSet onValueNotes
Slave IDCharge Controller2Must match the meter’s hardware config
Modbus address in Config UIMust match the hardware ID of the secondary meter. If both meters (primary and secondary) share an RTU bus, then their addresses must be different

1.3. Controller-Meter pairings (Double Charging Station)

Controller TypeConnects to Primary MeterConnects to Secondary/DLM Meter
Master (optional, Modbus or TCP)
Slave
tip

These rules apply to all compatible meters listed in this documentation, unless an exception is noted in the meter-specific info.

2. Supported meters

Support for the meters listed here has been implemented and can be chosen in the Config UI on the Charge Controller. To know how a meter is named in the Config UI, look at the Label in Config UI column.

ListInfo
Supported Eichrecht meters (Germany & Austria)Eichrecht-compliant meters. These can be used as general-purpose meters as well but are generally more expensive, hence they are not repeated in the "internal meters" list.
Supported internal metersThese meters are suitable for installation inside a Charging Station. Interfaces are as follows: Modbus RTU, RJ10 (SML), S0.
Supported DLM metersThese meters can be used in a DLM context.
Supported Solar DLM metersA subset of the "DLM meters" which are suitable and tested for Solar DLM.
Supported Hierarchical DLM metersThese meters are suitable and tested for Hierarchical DLM.

3. Supported Eichrecht meters (Germany & Austria)

The meters listed here can be set up to be Eichrecht-compliant, but can also be used as general-purpose meters.

ManufacturerModelLabel in Config UIConnection/ProtocolCable loss factorDuration-based invoicingSupported fromNote
EMHeHZ generation KeHZ MeterRJ10 / SMLNot possibleNot possible4.40Eichrecht with CC612 only
eHZBeHZ-B MeterRJ10 / SMLpossiblepossible5.32.0Price display for kwH and total price display for kwH.
EastronSDM 630 EVER Eastron SDM630-EVModbus RTUPossibleNot possible5.33.2
NZREcoCount SL+SC 85ER NZR EcoCount SL+SC 85Modbus RTUPossibleNot possible5.33.0
EcoCount SL+S 85ER NZR EcoCount SL+S 85Modbus RTUNot possibleNot possible5.33.0
ISKRAWM3M4CER Iskra WM3M4CModbus RTUPossibleNot possible5.33.0
Gossen MetrawattEM2289Meter ModbusModbus RTUPossiblePossible5.12.5Customer-specifc meter type
DZGDVH 4013Meter ModbusModbus RTUPossiblePossible5.23.0Eichrecht with CC612/CC613 only
DWH 4013Meter ModbusModbus RTUPossiblePossible5.21.1
DWH 4113Meter ModbusModbus RTUPossiblePossible5.23.0

4. Supported internal meters

ManufacturerModelLabel in Config UIConnection/ProtocolSupported fromAdditional info
ABBB23Modbus Meter ABBModbus RTU5.12.1
D1MModbus ABB D1MModbus RTU5.33.0
EV3Modbus ABB EV3Modbus RTU5.23.0
BERGB23Modbus Berg B23Modbus RTU5.33.3
BME 461Modbus Berg BME 461Modbus RTU5.30.0
Carlo GavazziEM111Modbus Meter Carlo Gavazzi EM111/112Modbus RTU5.32.0
EM112Modbus Meter Carlo Gavazzi EM111/112Modbus RTU5.32.0
EM200Modbus Meter Carlo Gavazzi EM200Modbus RTU5.20.5
EM210Modbus Meter Carlo Gavazzi EM210Modbus RTU5.23.0
EM340Modbus Meter Carlo Gavazzi EM340Modbus RTU5.12.1
EM540Modbus Meter Carlo Gavazzi EM540Modbus RTU5.34.0
DZGDVH4013Modbus DZG DVH4013Modbus RTU5.21.1
DWH4113Modbus DZG DWH4113Modbus RTU5.33.1
EastronSDM 120Modbus Eastron SDM120_220Modbus RTU5.23.0
SDM 220Modbus Eastron SDM120_220Modbus RTU5.23.0
SDM 630Modbus Meter Eastron SDM630Modbus RTU4.30
SDM72D-MModbus Eastron SDM72DModbus RTU5.12.1
SDM72D-M v2Modbus Eastron SDM72D-M-V2Modbus RTU5.33.2
ECSM3PROModbus ECS M3PROModbus RTU5.32.0
EetarpGEM230Modbus Eetarp GEM230Modbus RTU5.33.0
GEM630Modbus Eetarp GEM630Modbus RTU5.33.0
EMHeHZ generation KeHZ MeterRJ10 / SML4.40Interface only present on CC612
eHZBeHZ-B MeterRJ10 / SML5.33.0
Finder7E.x8Modbus Meter FinderModbus RTU4.30
7M38Modbus Meter Finder 7M38Modbus RTU5.30.0
GaroEM270Modbus Meter Garo EM270Modbus RTU4.30
GM3TModbus Meter Garo GM3TModbus RTU4.30
GMI3D LPModbus Meter Garo GMI3D-LPModbus RTU5.29.5
GNM1DModbus Meter Garo GNM1DModbus RTU4.30
GNM3DModbus Meter Garo GNM3DModbus RTU4.30
GNM3TModbus Meter Garo GNM3TModbus RTU5.23.0
GNM3TDModbus Meter Garo GNM3TDModbus RTU5.12.5
Gossen MetrawattEM2289Meter ModbusModbus RTU5.12.5
HagerECR380DModbus Hager ECR380DModbus RTU5.12.5
IMECE4DF3DTMIDModbus IME CE4DF3DTMIDModbus RTU5.33.5
CE4DMID31Modbus IME CE4DMID31Modbus RTU5.12.5
INEPROPRO1Modbus Inepro PRO1_2Modbus RTU5.12.5
PRO2Modbus Inepro PRO1_2Modbus RTU5.12.5
PRO380Modbus Inepro PRO380Modbus RTU5.20.6
IskraIE38MModbus Iskra IE38MModbus RTU5.20.8
WM3M6Modbus Iskra WM3M6Modbus RTU5.12.5
JanitzaUMG 512PROModbus Janitza UMG 512/96 PROModbus RTU5.12.5
UMG 605PROModbus Janitza UMG 605 PROModbus RTU5.12.5
UMG 96PROModbus Janitza UMG 512/96 PROModbus RTU5.23.0
LovatoDMED 301Modbus Lovato DMED 301Modbus RTU5.33.0
NZREcoCount S85Modbus NZR EcoCount S85/SL85Modbus RTU5.12.1
EcoCount SL85Modbus NZR EcoCount S85/SL85Modbus RTU5.12.7
OPTECModbus OptecModbus RTU4.30
Phoenix ContactEEM EM357Modbus Phoenix Contact EEM-EM357Modbus RTU5.29.4
SaiaALE3Modbus Saia ALE3Modbus RTU4.30Set parity to even
Schneider ElectriciEM3555Modbus Schneider iEM3555Modbus RTU5.22.1
Schneider GenericModbus Schneider GenericModbus RTU5.33.1Generic implementation for Schneider Electric meter
SELECEM2M-1P-C-100AModbus SELEC EM2M-1P-C-100AModbus RTU5.32.0
Siemens7KT1666Modbus Siemens 7KT1666Modbus RTU5.12.1
TQEM300LRModbus TQ EM300-LRModbus RTU5.23.0
EM410Modbus TQ EM410/EM420Modbus RTU5.23.0
EM420Modbus TQ EM410/EM420Modbus RTU5.23.0
WAGO879 3000Modbus Wago 879-3000Modbus RTU5.32.0
YTLDTS353FModbus YTL DTS353FModbus RTU5.32.0
Generic (S0 Meter)Any modelS0 Meter OptoS0 pulse meter5.12.1Default: 1000 pulses/kWh
Not recommended

5. Supported DLM meters

ManufacturerModelLabel in Config UIConnection/ProtocolSupported fromAdditional info
ABBB23Modbus Meter ABBModbus RTU5.12.1
D1MModbus ABB D1MModbus RTU5.33.0
D1MModbus ABB D1M (TCP)Ethernet Modbus TCP5.23.0
EV3Modbus ABB EV3Modbus RTU5.32.0
BERGB23Modbus Berg B23Modbus RTU5.33.0
BME 461Modbus Berg BME 461Modbus RTU5.30.0
Carlo GavazziEM111Modbus Meter Carlo Gavazzi EM111/112Modbus RTU5.32.0
EM112Modbus Meter Carlo Gavazzi EM111/112Modbus RTU5.32.0
EM200Modbus Meter Carlo Gavazzi EM200Modbus RTU5.20.5
EM210Modbus Meter Carlo Gavazzi EM210Modbus RTU5.23.0
EM340Modbus Meter Carlo Gavazzi EM340Modbus RTU5.32.0
EM540Modbus Meter Carlo Gavazzi EM540Modbus RTU5.34.0
DZGDVH4013Modbus DZG DVH4013Modbus RTU5.21.1
DWH4113Modbus DZG DWH4113Modbus RTU5.33.1
EastronSDM 120Modbus Eastron SDM120_220Modbus RTU5.23.0
SDM 220Modbus Eastron SDM120_220Modbus RTU5.23.0
SDM 630Modbus Meter Eastron SDM630Modbus RTU4.30
SDM 630-EVER Eastron SDM630-EVModbus RTU5.12.1
SDM72D-MModbus Eastron SDM72DModbus RTU5.12.1
SDM72D-M v2Modbus Eastron SDM72D-M-V2Modbus RTU5.33.2
ECSM3PROModbus ECS M3PROModbus RTU5.32.0
M3PROModbus ECS M3PRO (TCP)Ethernet Modbus TCP5.32.0
EetarpGEM230Modbus Eetarp GEM230Modbus RTU5.33.0
GEM630Modbus Eetarp GEM630Modbus RTU5.33.0
EMHeHZ generation KeHZ MeterRJ10 / SML4.30Interface only present on CC612
eHZBeHZ-B MeterRJ10 / SML5.33.0
Finder7E.x8Modbus Meter FinderModbus RTU4.30
7M38Modbus Meter Finder 7M38Modbus RTU5.30.0
GaroEM270Modbus Meter Garo EM270Modbus RTU4.30
GM3TModbus Meter Garo GM3TModbus RTU4.30
GMI3D LPModbus Meter Garo GMI3D-LPModbus RTU5.29.5
GNM1DModbus Meter Garo GNM1DModbus RTU4.30
GNM3DModbus Meter Garo GNM3DModbus RTU4.30
GNM3TModbus Meter Garo GNM3TModbus RTU5.23.0
GNM3TDModbus Meter Garo GNM3TDModbus RTU5.12.5
Gossen MetrawattEM2289Meter ModbusModbus RTU5.12.5
HagerECR380DModbus Hager ECR380DModbus RTU5.12.5
IMECE4DF3DTMIDModbus IME CE4DF3DTMIDModbus RTU5.33.5
CE4DMID31Modbus IME CE4DMID31Modbus RTU5.12.5
INEPROPRO1Modbus Inepro PRO1_2Modbus RTU5.12.5
PRO2Modbus Inepro PRO1_2Modbus RTU5.12.5
PRO380Modbus Inepro PRO380Modbus RTU5.20.6
IskraIE38MModbus Iskra IE38MModbus RTU5.20.8
WM3M4CER Iskra WM3M4CModbus RTU5.12.5WM3M4C expects L3 powered in single-phase operation. To allow for both 1ph and 3ph operation, the meter needs to be rotated 240deg before the meter and 120deg after. See the meter manual for more.
WM3M6Modbus Iskra WM3M6Modbus RTU5.12.5
JanitzaUMG 512PROModbus Janitza UMG 512/96 PROModbus RTU5.12.5
UMG 512PROModbus Janitza UMG 512/96 PRO (TCP)Ethernet Modbus TCP5.12.5
UMG 604PROModbus Janitza UMG 604 PRO (TCP)Ethernet Modbus TCP5.23.0Default Modbus ID: 1
UMG 605PROModbus Janitza UMG 605 PROModbus RTU5.12.5
UMG 605PROModbus Janitza UMG 605 PRO (TCP)Ethernet Modbus TCP5.12.5
UMG 96PROModbus Janitza UMG 512/96 PROModbus RTU5.23.0
UMG 96PROModbus Janitza UMG 512/96 PRO (TCP)Ethernet Modbus TCP5.23.0
LovatoDMED 301Modbus Lovato DMED 301Modbus RTU5.33.0
MennekesEV OPTIMIZEREV OptimizerEthernet Modbus TCP
NZREcoCount S85Modbus NZR EcoCount S85/SL85Modbus RTU5.12.1
EcoCount SL+S 85ER NZR EcoCount SL+S 85Modbus RTU5.12.7
EcoCount SL+SC 85ER NZR EcoCount SL+SC 85Modbus RTU5.33.1
EcoCount SL85Modbus NZR EcoCount S85/SL85Modbus RTU5.33.1
OPTECModbus OptecModbus RTU4.30
Phoenix ContactEEM EM357Modbus Phoenix Contact EEM-EM357Modbus RTU5.29.4
EMpro EEM MB371Modbus Phoenix Contact EEM-MB371 (TCP)Ethernet Modbus TCP5.12.5
SaiaALE3Modbus Saia ALE3Modbus RTU4.30Set parity to even
Schneider ElectriciEM3555Modbus Schneider iEM3555Modbus RTU5.22.1
Schneider GenericModbus Schneider GenericModbus RTU5.33.1Generic implementation for Schneider Electric meter
Schneider Generic (TCP)Modbus Schneider Generic (TCP)Ethernet Modbus TCP5.33.1
SELECEM2M-1P-C-100AModbus SELEC EM2M-1P-C-100AModbus RTU5.32.0
Siemens7KM2200Modbus Siemens 7KM2200 (TCP)Ethernet Modbus TCP5.22.1
7KT1666Modbus Siemens 7KT1666Modbus RTU5.12.1
SMACommercial Energy MeterSMA Commercial Energy Meter (TCP)Ethernet Modbus TCP5.33.1
Temco ControlsSPM1-XX0-ACModbus Temco Controls SPM1-XX0-ACModbus RTU5.33.1
TQEM300LRModbus TQ EM300-LRModbus RTU5.23.0
EM410Modbus TQ EM410/EM420Modbus RTU5.23.0
EM420Modbus TQ EM410/EM420Modbus RTU5.23.0
EM300LRModbus TQ EM300-LR (TCP)Ethernet Modbus TCP5.23.0
EM410Modbus TQ EM410/EM420 (TCP)Ethernet Modbus TCP5.23.0
EM420Modbus TQ EM410/EM420 (TCP)Ethernet Modbus TCP5.23.0
WAGO879 3000Modbus Wago 879-3000Modbus RTU5.32.0
Walther WerkeIPD CONTROLModbus IPD Control (TCP)Ethernet Modbus TCP5.29.1
YTLDTS353FModbus YTL DTS353FModbus RTU5.32.0
WiMODIR Reader USB stickWiMOD IR Reader USB stickeHZ meterSecond meter only

6. Supported Solar DLM Meters

ManufacturerModelDescription in constraint FileConnection/ProtocolSupported fromAdditional info
Phoenix ContactEMpro EEM MB371Modbus Phoenix Contact EEM-MB371 (TCP)Ethernet Modbus TCP5.33.1
SiemensModbus Siemens 7KM2200 (TCP)Modbus Siemens 7KM2200 (TCP)Ethernet Modbus TCP5.33.1
TQEM410Modbus TQ EM410/EM420 (TCP)Ethernet Modbus TCP5.33.1
EM420Modbus TQ EM410/EM420 (TCP)Ethernet Modbus TCP5.33.1
ABBB23Modbus Meter ABBModbus RTU5.33.3
info

This list applies to SDLM when the Configure Solar Mode for DLM setting is set to Grid Charging.
Otherwise if the setting is set to any other mode, any supported meter can be used.

7. Supported Hierarchical DLM Meters

ManufacturerModelDescription in constraint FileConnection/ProtocolSupported fromAdditional info
Phoenix ContactPhoenix Contact EEM-MB371EEM-MB371Modbus TCP5.32.0
Gossen MetrawattGossen Metrawatt EM2289em2289Modbus TCP5.32.0