Skip to main content
v5.33
manufacturer
Last updated on

RFID and HMI accessories

One common authentication method is RFID. This also includes NFC technology. These form the basis of all charging cards. Central to the identification is the UID (Unique IDentifier) of an RFID chip.

1. Hardware

Here's a list of available RFID and HMI hardware accessories:

Model
Compatible Charge Controller models
#
RFID117-L1
CC612 and CC613 (all variants)
#
RFID114
#
RFID105-L1
#
RFID110
contact Bender sales
#
HMI150
CC612, CC613, ICC1324, and ICC1314
#
HMI145
#
HMI140

1.1. Associated equipment

1.2. Installation and activation

The RFID module is placed beneath a semi-transparent part of the charging system housing. It should be positioned with a minimum distance of 20 mm from any metal surfaces or metal components to ensure optimal reading performance.

  1. Log in to the Legacy Config UI using the default Manufacturer Login Credentials
  2. Under Manufacturer set Enable RFID to On
  3. Under Manufacturer, set Type of Display to Bender LCD-Module DPM2x16FP
  4. At the bottom of the Legacy Config UI, click to apply the changes
tip

When no RFID module is installed, set Enable RFID to Off. This prevents error messages.

2. RFID support

2.1. Standards

Supported RFID-related standards:

ISO/IEC 14443 A 1-4
ISO/IEC 7816
NFC Forum Type 2
MIFARE® EV1-2
3DES Encryption
EN 50364
EN IEC 61851-21-2
EN IEC 62368-1
EN IEC 63000
ETSI EN 300 330
ETSI EN 301 489-1
ETSI EN 301 489-3

2.2. Tag types

The Charge Controller family supports all MIFARE® variants:

MIFARE Classic® EV1 1K-4K
MIFARE Ultralight®
MIFARE Ultralight® EV1
MIFARE Ultralight® C
MIFARE Plus® S
MIFARE Plus® X
MIFARE Plus® SE
MIFARE Plus® EV2
MIFARE® DESFire®
MIFARE® DESFire® EV1-3
MIFARE® 2GO
MIFARE® SmartMX

2.3. Additional notes

  • With the MIFARE® DESFire® EV2, we support the EV2 security features
  • Only the UID can be read
  • Limited support for rolling UIDs. We advise against rolling UIDs

2.4. Recommendations

  • For increased security, always use EV2