Manufacturer options
1 Security tips
- Have options for password recovery set up
- Set a safe Manufacturer password. Various password generators are available on the web
- Setting individual passwords per Charging Station increases cybersecurity. The drawback: maintenance. Decide at your own discretion
- If you do opt for individual passwords, we recommend keeping the passwords identical between Master-Slave Charging Controllers in a double Charging Station
2 Managing passwords
To ensure secure configuration, set a password for each role:
- Manufacturer
- Installer
- Operator
- User
so that the default passwords can't be used anywhere.
Keep the Manufacturer password secure as leaking it could give malicious actors access to safety-compromising configuration options.
Additionally, we recommend to advise your CPOs to set passwords individual to each Charge Controller of their charging infrastructure.
3 Setting the Manufacturer password
- Log in to the using the Manufacturer
-
Apply the following configuration:
Scope | Location in | Field | Value |
|---|---|---|---|
| # Manufacturer | Manufacturer > Manufacturer Password | Manufacturer Password (enter the current password to confirm) | existing login password |
Manufacturer Password | new password you want to set |
- At the bottom of the , click , then click to apply the changes
- On Double Charging Stations: repeat the steps above on the Slave Charge Controller
Password safety options for the Operator login
Manufacturers can manage Operators' password safety through the following settings:
Scope | Location in | Field | Value | Info |
|---|---|---|---|---|
| # Manufacturer | Manufacturer > Manufacturer Password | Enforce Password change | on | Force change of Operator password on the next login attempt |
Enforce strong login passwords | on | Enforce the following requirements on new passwords:
|
3.1 Password recovery and PUK settings
There are two ways to ensure a password recovery is possible for the Operator:
- Password Reset PUK
- Master RFID Card
The PUK should only be shared with CPOs when needed.
Using the PUK, Operators can issue a password reset.
- Log in to the using the Manufacturer
- Under Manufacturer, set a
Reset Password PUK - At the bottom of the , click , then click to apply the changes
PUK recommendations
- The PUK should be at least 8 characters long
- The maximal PUK length is 80 characters
- You can use up to 80 ASCII characters from the following set to create the PUK:
!@#$%^&*()-_=+[]{}|:;.,/?ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz0123456789
- Avoid using special characters that require escaping, such as
\,", or'.
Manufacturers can configure a Master RFID card, enabling the following:
- Password reset: Resetting the password for every role
- Manufacturer defaults: When the master RFID is continuously scanned for 2 minutes, the Charging Station is set back to the Manufacturer defaults
Manufacturers can pre-configure an RFID card to be used as a Master RFID Card and bundle it with the Charging Station at hand-over.
Alternatively, Manufacturers can hand out 1-2 blank RFID cards for later use by Operators for the purpose of password reset.
Multiple recovery options (for example the PUK and a Master RFID) can be active at the same time. They are independent — enable only the options you intend and document which recovery methods are available to the Operator.
3.2 Operator registration of a Master RFID via Web UI 2.0
Inform your Operators that they can register a Master RFID themselves using the Web UI 2.0: go to System > Change Operator Password, provide the current Operator password and enter the Master RFID during the password change process. This requires no additional configuration; the Operator must know their current password to perform this action.
Configuring a Master RFID card for password recovery and configuration reset
(operator) http://192.168.123.123/groups/authorization -> AUTHORIZATION -> Enforce Master RFID
http://192.168.123.123/legacy/manufacturer/manufacturer -> Enforce Master RFID
http://192.168.123.123/legacy/manufacturer/operator -> Factory Reset by RFID
4 security
On some Charge Controllers, the is activated by default. Before handing Charging Stations over to Operators, we recommend fully disabling the or at least changing the default to .
Besides improved cybersecurity measures, the non-legacy allows for communication over HTTPS.
4.1 selection options
-
Apply the following configuration:
Scope | Location in | Field | Value | Info |
|---|---|---|---|---|
| # Operator | Operator > Web Interface | Web Interface | 1.0 (legacy) | Sets the as the default |
2.0 | Sets the as the default. The is still available | |||
2.0 only | Sets the as the default and disables access to the . Attention: this can only be reset by the Manufacturer through SSH |
- At the bottom of the , click , then click to apply the changes
Reverting the 2.0 only option
-
SSH into the Charge Controller as
chargeusing the - Navigate to
/persistencyand delete theWebUIStyle_webfile via this command:
rm WebUIStyle_web
4.2 Enabling HTTPS
- Log in to the using the Operator
- Under SYSTEM > HTTPS set
Enable HTTPStoOn - At the bottom of the , click , then click to apply the changes
Because there's no way to validate the IP address of each Charge Controller, you will get a security warning asking you to validate the HTTPS certificate. You can ignore the warning and proceed to the .
5 Log encryption
Logs can be encrypted with a password to protect sensitive data contained in logs. Here's how:
- Log in to the using the Manufacturer
- Under Manufacturer > Manufacturer Password set the
Log PasswordThis is the password for the downloadable log zip file - At the bottom of the , click , then click to apply the changes