v5.32
operator
manufacturer
Last updated on
Station model
1. Parameter scope
In dual-connector stations, configuration parameters are scoped explicitly.
The scope found in the Config UI under:
Config UI → Documentation → OCPP Keys
defines how a parameter applies to the connectors.
Scope | Meaning | What this means in practice |
|---|---|---|
| # Both | One shared value for both connectors | Changing the value affects connector 1 and 2 equally |
| # Individual | Separate values per connector | Connector 2 uses the _2 variant of the key |
| # Not relevant | Not tied to a connector | Applies to the whole station |
| # Master | Applies only to the backend-facing coordinator | Affects backend communication and coordination only |
1.1. Master-scoped parameters
Some parameters are marked Master in the Config UI.
- These parameters are configured and evaluated on the station coordinator (connector 1).
- Their effect may be station-wide, depending on the feature.
- Connector-specific behavior is handled through Individual parameters (
_2).
tip
For Master scope, configure the value on the station coordinator only (connector 1).
1.2. Connector-specific suffix
For Individual parameters:
- Connector 1 uses the OCPP key without a suffix.
- Connector 2 uses the
_2suffix.
This pattern applies to all connector-scoped OCPP parameters.
Example: Connector phase rotation
// Connector 1
{"key": "ConnectorPhaseRotation", "value": "RST"}
// Connector 2
{"key": "ConnectorPhaseRotation_2", "value": "RTS"}
The _2 suffix changes the behavior of connector 2 only.
2. Coordinator Behavior (Dual-Connector Stations)
- The backend connects to an OCPP backend through one of the connectors
- The active backend connection determines which connector acts as connector 1
- Regardless of backend connection state, connector 1 is typically also the Master Controller outside of OCPP communication
- The station internally coordinates between the two connectors
- The backend sees a single Charging Station with two connectors
- There is never a separate backend connection for connector 2